1. Surgical outcomes of cable plate fixation in treatment of Vancouver type B1 and type C periprosthetic femoral fractures: a retrospective case series.
- Author
-
Şen C, Kızılkurt T, Demirel M, Yıldırım AM, Sağlam Y, and Öztürk İ
- Subjects
- Humans, Female, Male, Middle Aged, Retrospective Studies, Aged, Treatment Outcome, Adult, Aged, 80 and over, Fracture Healing, Young Adult, Adolescent, Postoperative Complications, Arthroplasty, Replacement, Hip methods, Arthroplasty, Replacement, Hip adverse effects, Arthroplasty, Replacement, Hip instrumentation, Femoral Fractures surgery, Femoral Fractures classification, Periprosthetic Fractures surgery, Periprosthetic Fractures classification, Fracture Fixation, Internal methods, Fracture Fixation, Internal instrumentation, Bone Plates
- Abstract
This study aimed to investigate the mid-to-long-term surgical outcomes of open reduction and internal fixation (ORIF) using a hybrid locking plate/cable technique for the treatment of Vancouver type B1 and type C periprosthetic femoral fractures (PPFs) in a consecutive group of patients from a single tertiary referral center. Twenty-five patients (25 PPFs; 17 female, 8 male) in whom a Vancouver type B1 or type C PPF was diagnosed and treated by a hybrid locking plate/cable technique from 2005 to 2016 were included in the study. Patients' functional status was categorized into 4 groups based on the Harris Hip Score (HHS) at the final follow-up: 70=poor result; 70-80=fair; 80-90=good, and 90-100=excellent. Intraand postoperative complications were also recorded. PPF union was defined clinically as the patient's ability to bear full weight with or without assistance and radiographically as the presence of a callus bridging the fracture. Subgroup analyses were conducted according to the Vancouver classification and type of fixation regarding the HHS and time to union. The mean age was 57 ± 16.6 (range, 17-82) years at the time of the primary hip replacement and 64 ± 18.7 (range, 24-88) years at the time of PPF. The mean follow-up was 5.6 ± 3.3 (range, 2-14) years from primary procedure to PPF and 6.5 ± 4.1 (range, 3-15) years following PPF. There were 7 type B1 and 18 type C PPFs. At the final follow-up, the mean HHS was 71 ± 7.74 (range, 57-89). According to HHS, functional results were poor in 8 patients, fair in 14 patients, and good in 3 patients. No major intra- or postoperative complications were noted. Fracture union was achieved in all patients without complications at an average of 13 ± 4.9 (range, 6-24) weeks. In subgroup analysis, while no significant differences were observed in the HHS (P=.87 for the Vancouver type, P=.96 for the type of fixation), time to union differed among groups. Time to union was significantly shorter in type B1 than in type C PPFs (P=.006). Time to union was considerably shorter in the uncemented group compared to the cemented one (P=.017). Adding cables to the locking plate can provide adequate stability to preserve fracture alignment and achieve bony union in Vancouver type B1 and C PPFs. Although union can be achieved by ORIF in such patients, a longer union time may be required for PPFs in the setting of a cemented femoral stem or Vancouver type C. Level IV, Therapeutic study.
- Published
- 2024
- Full Text
- View/download PDF