1. Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study
- Author
-
Federico Gómez-Pulido, Manuel Frutos-López, Juan Acosta, Álvaro Arce-León, Lorena García-Riesco, Eduardo Arana-Rueda, José Luis Martos‐Maine, Alonso Pedrote, and Juan A. Sánchez-Brotons
- Subjects
medicine.medical_specialty ,medicine.diagnostic_test ,business.industry ,Paroxysmal atrial fibrillation ,Radiofrequency ablation ,medicine.medical_treatment ,General Medicine ,030204 cardiovascular system & hematology ,Ablation ,Pulmonary vein ,Surgery ,law.invention ,03 medical and health sciences ,Catheter ,0302 clinical medicine ,Randomized controlled trial ,law ,medicine ,Fluoroscopy ,030212 general & internal medicine ,Cardiology and Cardiovascular Medicine ,Nuclear medicine ,business - Abstract
BACKGROUND The impact of contact force (CF) monitoring in pulmonary vein (PV) isolation after a circumferential anatomic ablation (CAA) is unknown. We analyze the usefulness of CF monitoring in acute PV isolation and procedure parameters using a CAA. METHODS Fifty patients with paroxysmal atrial fibrillation were randomized into CF-on (CF >10 grams; n = 25) or CF-off (CF blinded; n = 25) groups. We performed a first round of CAA with a ThermoCool(®) SmartTouch(®) catheter blinded to the LASSO(®) catheter (Biosense Webster, Diamond Bar, CA, USA), with radiofrequency (RF) lesions tagged with the VisiTag(™) Module. After the CAA, each PV was reviewed with the LASSO(®) catheter recording the segments with gaps. RESULTS All the PVs were isolated with a CAA in 20 patients of the CF-on versus eight of the CF-off (P = 0.001). Of the 45 segments with gaps in the left PVs, 38 were from the CF-off (P = 0.0001). Of the eight segments with gaps in the right PVs, seven were from the CF-off (P = 0.06). The CF in the left PVs was higher in the CF-on (16.3 ± 3.2 grams vs 10.5 ± 4.3 grams; P = 0.0001) and similar in the right PVs (17.6 ± 3.6 grams vs 15.2 ± 5.3 grams; P = 0.08). All of the gaps were closed with additional RF LASSO(®) -guided touch-up. Procedure and fluoroscopy times were shorter in the CF-on (139 ± 24 minutes vs 157 ± 32 minutes and 20 ± 6 minutes vs 24 ± 7 minutes; both P = 0.039). At 12 months the patients free of AF recurrence was 84% CF-on versus 75% CF-off (log-rank P = 0.4) [corrected]. CONCLUSIONS In paroxysmal atrial fibrillation, a CAA guided by CF reduces PV gaps and shortens the procedure parameters at the expense of the left PVs.
- Published
- 2016
- Full Text
- View/download PDF