1. Left atrial to coronary sinus shunting for treatment of heart failure with mildly reduced or preserved ejection fraction: The ALT FLOW Early Feasibility Study 1‐year results.
- Author
-
Urey, Marcus A., Hibbert, Benjamin, Jorde, Ulrich, Eckman, Peter, Simard, Trevor, Labinaz, Marino, Nazer, Babak, Wiley, Mark, Gupta, Bhanu, Sauer, Andrew, Shah, Hirak, Sorajja, Paul, Pineda, Andres M., Missov, Emil, Mahmud, Ehtisham, Kahwash, Rami, Lilly, Scott, Latib, Azeem, Murthy, Sandhya, and Fam, Neil
- Subjects
LEFT heart atrium ,HEART failure ,VENTRICULAR ejection fraction ,CEREBROSPINAL fluid shunts ,TREATMENT failure ,HEART failure patients ,FEASIBILITY studies - Abstract
Aims: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT‐FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. Methods and results: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow‐up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ‐OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was −5.7 (−8.6, −2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I–II status and improved to 68% at 1 year (p < 0.001). KCCQ‐OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20–30) and 27 (22–32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ‐OSS in multiple subgroups were consistent with those observed for the entire population. Conclusions: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient‐centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF