327 results on '"Lens Diseases"'
Search Results
2. Effectiveness of Periocular Drug Injection in CATaract Surgery (EPICAT)
- Author
-
European Society of Cataract and Refractive Surgeons and Luigi Rondas, Coordinating Investigator ESCRS EPICAT study
- Published
- 2024
3. Accuracy of Intra Ocular Lens CARLEVALE Calculation
- Published
- 2024
4. A Prospective Trial of the Intelon BOSS(TM) System
- Published
- 2022
5. PRO Measure for Refractive Surgery IRAS Project Number 246072
- Published
- 2022
6. Correlations Between Lens Star and Phacoemulsification.
- Author
-
Ahmed Abdelshafy, Lecturer of Ophthalmology
- Published
- 2022
7. Retinal Detachment After Lens Surgery in the Nearsighted (A09F0401)
- Published
- 2019
8. Association Between Pseudoexfoliation Syndrome and Diabetes Mellitus
- Author
-
gehad salah eldin galal, Principal investigator
- Published
- 2018
9. Bilateral ocular deposit of chlorpromazine.
- Author
-
Teixeira Flügel, Nayara, Steuernagel Del Valle, Giulia, and Wasilewski, Daniel
- Subjects
- *
CHLORPROMAZINE , *CRYSTALLINE lens , *DRUG dosage , *CORNEA , *PSYCHOSES , *CATARACT , *PRESBYOPIA - Abstract
Chlorpromazine is a medication widely used in psychiatry for the treatment of psychoses, especially schizophrenia. Since 1964, published articles have been correlating this medication with the appearance of ocular alterations. In this paper, we report the case of a 65-year-old patient with ocular effects due to long-term therapy with chlorpromazine. Biomicroscopy of both eyes presented diffuse granular brown deposits, most prominent at the deep stroma and corneal endothelium level. Also showed anterior subcapsular brown deposits with a stellate pattern in the lens. The total amount exceeds 2.000g (significant for the ocular alterations described) considering the patient's daily dosage of chlorpromazine of 300mg for ten years. After performing complete ophthalmic evaluation and discarding other causes for the ocular deposits, we diagnosed a secondary corneal deposit and cataract due to the use of chlorpromazine. This case reinforces the importance of periodic follow-up with an ophthalmologist for chlorpromazine users to trace ocular changes, heeding the exposure time and its dosage. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF
10. Is it a coloboma or not? A new definition for isolated lens coloboma: focal zonular dysgenesis
- Author
-
Nicole B Larivoir, Paula M Marinho, Ivan C Teixeira, Gabriel B De Figueiredo, Rodrigo A B. Fernandes, and Lincoln L Freitas
- Subjects
cataract ,coloboma ,intraocular ,lenses ,lens diseases ,phacoemulsification ,Ophthalmology ,RE1-994 - Abstract
Purpose: Ocular coloboma is defined as a congenital malformation caused by defective closure of the fetal fissure, resulting in a notch in any structure. However, the entity known as “isolated lens coloboma” does not seem to have a similar etiological basis with other ocular colobomas. This congenital malformation can induce an important decrease of the visual acuity, and facectomy has an increased risk for intraoperative and postoperative complications. Better surgical planning could be achieved with an accurate definition of the diagnosis and pathophysiology of this lens abnormality, as the extent and mechanism of zonular disease will have a significant impact on the selection of the modality of intervention. Methods: Nine eyes of seven patients, who were diagnosed with “isolated lens coloboma” and underwent phacoemulsification and implant of intraocular lens (IOL), were studied (retrospective case series). The surgeries were performed by four different surgeons, according to their preferred technique, in the last 5 years. Results: There were no intraoperative complications. Two (22.22%) eyes presented postoperative complications, one of which was the IOL decentralization. Conclusion: Considering the ocular morphogenesis and the definition of coloboma, the ideal denomination for the congenital malformation traditionally known as isolated lens coloboma would be “focal zonular dysgenesis.” The best surgical approach, contemplating the pathophysiology, in addition to the cases described and review of literature, is discussed.
- Published
- 2023
- Full Text
- View/download PDF
11. Visual Performance of Pseudophakic Patient With Different Intraocular Lenses (ETDRS)
- Author
-
University of Sao Paulo and Wilson Takashi Hida, MD PhD
- Published
- 2016
12. Role of lens vault in subtypes of angle closure in Iranian subjects
- Author
-
Moghimi, S, Vahedian, Z, Zandvakil, N, Mohammdi, M, Fakhraie, G, Nassiri, N, Coleman, AL, and Lin, S
- Subjects
Clinical Research ,Eye Disease and Disorders of Vision ,Eye ,Anterior Chamber ,Biometry ,Cross-Sectional Studies ,Female ,Glaucoma ,Angle-Closure ,Gonioscopy ,Humans ,Intraocular Pressure ,Iran ,Iris Diseases ,Lens Diseases ,Male ,Middle Aged ,Prospective Studies ,Tomography ,Optical Coherence ,Tonometry ,Ocular ,anterior segment optical coherence tomography ,angle closure ,glaucoma ,lens vault ,iris curvature ,Clinical Sciences ,Immunology ,Opthalmology and Optometry ,Ophthalmology & Optometry - Abstract
PurposeThe purpose of this study is to quantify anterior chamber (AC) parameters and to determine the proportion of eyes with exaggerated lens vault (LV) in different subtypes of angle closure disease using anterior segment optical coherence tomography (AS-OCT).Patients and methodsIn this prospective study, 115 eyes of 115 Iranian patients with angle closure disease were included and categorized into three groups: (1) fellow eyes of acute angle closure (AAC; 40 eyes); (2) primary angle closure glaucoma (PACG; 39 eyes); and (3) primary angle closure suspect (PACS; 36 eyes). Complete ophthalmic examination including gonioscopy, A-scan biometry, and AS-OCT were performed. Angle parameters, LV, and iris thickness (IT) were measured using AS-OCT. An exaggerated LV was defined as LV more than one-third the distance between the corneal endothelium and a line drawn to connect the nasal and temporal scleral spurs.ResultsFellow eyes of AAC had the shallower AC (P=0.01), greater iris curvature (I-curve; P=0.01), and higher LV (P=0.02) as compared with PACS and PACG eyes. There was no statistically significant difference in the mean IT at 750 μm from scleral spur among the three groups (P=0.45). Exaggerated LV was found in 67.5, 35.9, and 40% of fellow eyes of AAC, PACG, and PACS, respectively, (P=0.008) with an odds ratio of 1.92 (P=0.005) for fellow vs PACG and 1.68 (P=0.01) for fellow vs PACS.ConclusionsExaggerated LV is highly prevalent in fellow eyes of AAC. These eyes have shallower AC depth, greater I-curve, and higher LV when compared with PACG and PACS.
- Published
- 2014
13. Comparison of 25 MHz and 50 MHz ultrasound biomicroscopy for imaging of the lens and its related diseases
- Author
-
Ming-Yu Shi, Xiao Han, Jin-Song Zhang, and Qi-Chang Yan
- Subjects
1157 ,25 MHz ultrasound biomicroscopy ,50 MHz ultrasound biomicroscopy ,lens diseases ,Ophthalmology ,RE1-994 - Abstract
AIM: To compare the results of 25 MHz and 50 MHz ultrasound biomicroscopy (UBM) regarding the image characteristics of the lens and its related diseases and to discuss the application value of 25 MHz UBM in ophthalmology. METHODS: A total of 302 patients (455 eyes) were included in this study from November 2014 to May 2015. Patient ages ranged from 5 to 89y (mean±SD: 61.0±17.7y). Different cross-sectional images of the lens were collected to compare and analyze the image characteristics and anterior segment parameters using 25 MHz and 50 MHz UBM in axial and longitudinal scanning modes, respectively. SPSS 19.0 for Windows, paired t-tests and B&A plot analysis were used for data analysis, and a value of P
- Published
- 2018
- Full Text
- View/download PDF
14. Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer
- Author
-
Arriola Villalobos, Pedro, Almendral Gómez, Jaime, Garzón Jiménez, Nuria, Ruiz Medrano, Jorge, Fernández Pérez, Cristina, Martínez De La Casa Fernández-Borrella, José María, Díaz Valle, David, Arriola Villalobos, Pedro, Almendral Gómez, Jaime, Garzón Jiménez, Nuria, Ruiz Medrano, Jorge, Fernández Pérez, Cristina, Martínez De La Casa Fernández-Borrella, José María, and Díaz Valle, David
- Abstract
Purpose To compare measurements taken using a swept-source optical coherence tomography-based optical biometer (IOLmaster 700) and an optical low-coherence reflectometry biometer (Lenstar 900), and to determine the clinical impacts of differences in their measurements on intraocular lens (IOL) power predictions. Methods Eighty eyes of 80 patients scheduled to undergo cataract surgery were examined with both biometers. The measurements made using each device were axial length (AL), central corneal thickness (CCT), aqueous depth (AQD), lens thickness (LT), mean keratometry (MK), white-to-white distance (WTW), and pupil diameter (PD). Holladay 2 and SRK/T formulas were used to calculate IOL power. Differences in measurement between the two biometers were determined using the paired t-test. Agreement was assessed through intraclass correlation coefficients (ICC) and Bland-Altman plots. Results Mean patient age was 76.3±6.8 years (range 59-89). Using the Lenstar, AL and PD could not be measured in 12.5 and 5.25% of eyes, respectively, while IOLMaster 700 took all measurements in all eyes. The variables CCT, AQD, LT, and MK varied significantly between the two biometers. According to ICCs, correlation between measurements made with both devices was excellent except for WTW and PD. Using the SRK/T formula, IOL power prediction based on the data from the two devices were statistically different, but differences were not clinically significant. Conclusions No clinically relevant differences were detected between the biometers in terms of their measurements and IOL power predictions. Using the IOLMaster 700, it was easier to obtain biometric measurements in eyes with less transparent ocular media or longer AL., Unidad Docente de Inmunología, Oftalmología y ORL, Fac. de Óptica y Optometría, TRUE, pub
- Published
- 2023
15. Spherical Aberration and Contrast Sensitivity in IOLs (IOLs)
- Author
-
Patrick Frensel de Moraes Tzelikis
- Published
- 2008
16. Magnetic Resonance Imaging to Study the Normal Eye
- Published
- 2008
17. Visual preconditioning reduces emergence delirium in children undergoing ophthalmic surgery: a randomised controlled trial.
- Author
-
Lin, Y., Shen, W., Liu, Y., Wang, Q., Chen, Q., Fang, Z., Chi, W., Gan, X., and Liu, Y.Z.
- Subjects
- *
DELIRIUM , *CATARACT surgery , *OPHTHALMIC surgery , *SEVOFLURANE , *PEDIATRIC anesthesia , *PRESCHOOL children - Abstract
Background: Emergence delirium is a common complication in children, especially in preschool children undergoing ophthalmic surgery. The aim of the study was to investigate the effects of visual preconditioning (application of an eyepatch over the eye to be operated for ≥3 h the day before surgery) on emergence delirium after ophthalmic surgery under sevoflurane anaesthesia.Methods: One hundred and seventy-nine children undergoing unilateral cataract surgery, aged 3-7 yr, were involved in this prospective, blinded, randomised study. Subjects were randomised to receive visual preconditioning (Group P, n=89) or to receive programmed explanation the day before surgery (Group C, n=90). The primary outcome was incidence of emergence delirium evaluated by the paediatric anaesthesia emergence delirium (PAED) scale. The secondary outcomes included emergence time and post-anaesthesia care unit (PACU) stay time.Results: Children in Group P had a significantly lower incidence of emergence delirium than those in Group C [16.9% vs 44.4%, odds ratio (OR) 4.0, 95% confidence interval (CI) 2.0 to 8.0]. The maximal PAED score was lower in Group P than in Group C [4 (0-20) vs 9 (0-20), median difference -3.0, 95% CI -5.0 to -1.0]. Visual preconditioning prolonged emergence time (P<0.001) and PACU stay time (P=0.002).Conclusion: Visual disturbance contributes to emergence delirium in preschool children undergoing ophthalmic surgery with sevoflurane, and prophylactic eyepatch treatment can reduce emergence delirium.Clinical Trials Registration: NCT02590744. [ABSTRACT FROM AUTHOR]- Published
- 2018
- Full Text
- View/download PDF
18. Depósito ocular bilateral de clorpromazina
- Author
-
Flügel,Nayara Teixeira, Valle,Giulia Steuernagel Del, and Wasilewski,Daniel
- Subjects
Cornea ,Lens, crystalline ,Antipsychotics agents ,Córnea ,Chlorpromazine ,Doenças do cristalino ,Lens diseases ,Catarata ,Antipsicóticos ,Cristalino ,Clorpromazina ,Cataract - Abstract
Chlorpromazine is a medication widely used in psychiatry for the treatment of psychoses, especially schizophrenia. Since 1964, published articles have been correlating this medication with the appearance of ocular alterations. In this paper, we report the case of a 65-year-old patient with ocular effects due to long-term therapy with chlorpromazine. Biomicroscopy of both eyes presented diffuse granular brown deposits, most prominent at the deep stroma and corneal endothelium level. Also showed anterior subcapsular brown deposits with a stellate pattern in the lens. The total amount exceeds 2.000g (significant for the ocular alterations described) considering the patient's daily dosage of chlorpromazine of 300mg for ten years. After performing complete ophthalmic evaluation and discarding other causes for the ocular deposits, we diagnosed a secondary corneal deposit and cataract due to the use of chlorpromazine. This case reinforces the importance of periodic follow-up with an ophthalmologist for chlorpromazine users to trace ocular changes, heeding the exposure time and its dosage. RESUMO A clorpromazina é uma medicação muito empregada na psiquiatria para tratamento de psicoses, especialmente em casos de esquizofrenia. Desde 1964 existem artigos publicados que correlacionam o uso dessa medicação com o aparecimento de alterações oculares. Neste trabalho, relatamos o caso de um paciente de 65 anos com efeitos oculares devido à terapia de longo prazo com clorpromazina. A biomicroscopia de ambos os olhos apresentou depósitos granulares difusos e de cor marrom, mais proeminente ao nível do estroma profundo e do endotélio da córnea, além de depósitos castanhos subcapsulares anteriores centrais em um padrão estrelado no cristalino. Considerando a dose diária de clorpromazina de 300mg por 10 anos usada pelo paciente, a quantidade total ultrapassa 2.000g (dose considerada significativa para as alterações oculares descritas). Após avaliação oftalmológica completa e descartado outras causas desses depósitos oculares, foram diagnosticados depósito corneano e catarata secundários ao uso de clorpromazina. O caso apresentado reforça a importância do acompanhamento oftalmolÓgico periÓdico de usuários de clorpromazina para o rastreio de alteraçÕes oculares, atentando-se ao tempo de exposição à droga e à posologia da mesma.
- Published
- 2022
19. Investigation of Ocular Alterations in Patients with Alopecia Areata and Its Correlation with the Severity of Disease
- Author
-
Ameneh Yazdanfar, Fatemeh Eslami, Mahtab Feizian, Farzaneh Esna Ashari, Seyyedeh Bita Sharafi, and Leila Khezrian
- Subjects
alopecia areata ,lens diseases ,retinal pigments ,Medicine - Abstract
Introduction & Objective: Alopecia areata is the most common skin disease that presents as areas without hair and may affect any hair bearing area of body. Different reports about ocular alterations in patients with alopecia areata are presented. The aim of this study was to evaluate the ocular alterations in patients with this disease. Material & Methods: In this descriptive - analytic study, 251 patients with alopecia areata were studied. Patients data including age, sex, age of disease onset,first site of involvment, disease duration, number of relapses,family history of atopy, and disease severity were recorded. Eye examination by an eye specialist was performed in all patients, and results were recorded. Findings were analyzed with SPSS 16 software, and using one way ANOVA and χ2 statisti-cal tests. Result: The mean age of patients in this study was 24.86 ± 5.92 years. Of the 251 patients, 200 (79.9%) had no ocular alterations and 51 (20.1%) showed visual alterations. Most of ocular alterations observed in this study were pigmentary changes of retina seen in 20 patients (8%). There was no significant correlation between disease severity and ocular changes. Conclusions: The results showed that ocular alterations were seen in some of patients with alopecia areata and not correlated with disease severity, mean patient age, patient gender, family history of atopy and allergy, the mean age of disease onset, mean number of relapses, and first site of involvment.
- Published
- 2014
20. Intraocular lens power calculations in eyes with pseudoexfoliation syndrome
- Author
-
Aleksandra Wlaź, Agnieszka Kustra, Agnieszka Rozegnał-Madej, and Tomasz Żarnowski
- Subjects
medicine.medical_specialty ,genetic structures ,Mean squared prediction error ,medicine.medical_treatment ,Science ,Visual Acuity ,Pseudoexfoliation syndrome ,Mean absolute error ,After cataract ,Intraocular lens ,Cataract Extraction ,Exfoliation Syndrome ,Article ,Lens Implantation, Intraocular ,Ophthalmology ,medicine ,Humans ,Prospective Studies ,Trial registration ,Eye diseases ,Lenses, Intraocular ,Multidisciplinary ,business.industry ,medicine.disease ,eye diseases ,Intraocular lens power ,Case-Control Studies ,Medicine ,Lens diseases ,sense organs ,business - Abstract
To compare refractive outcomes after cataract surgery in pseudoexfoliation syndrome (PEX) and control eyes and to investigate the accuracy of 3 intraocular lens (IOL) calculation formulas in these eyes. In this prospective comparative study 42 eyes (PEX group) and 38 eyes (control group) of 80 patients were included. The follow-up was 3 months. The refractive prediction error (RPE), mean absolute error (MAE), median absolute error (MedAE) and the percentages of eyes within ± 0.25 D, ± 0.5 D, ± 1.0 D and ± 2.0 D of prediction error were calculated. Three IOL calculation formulas (SRK/T, Barrett Universal II and Hill-RBF) were evaluated. PEX produced statistically significantly higher mean absolute errors and lower percentages of eyes within ± 0.5 D than control eyes in all investigated IOL calculation formulas. There were no statistically significant differences in the median absolute errors between the 3 formulas in either PEX or control eyes. Refractive outcomes after cataract surgery are statistically significantly worse in PEX than in control eyes. All three IOL calculation formulas produced similar results in both PEX and control eyes.Trial registration: ClinicalTrials.gov registration number NCT04783909.
- Published
- 2021
21. A large multiethnic GWAS meta-analysis of cataract identifies new risk loci and sex-specific effects
- Author
-
Salil A. Lachke, Pirro G. Hysi, Ronald B. Melles, Deepti Anand, Hélène Choquet, Gabriel Cuellar-Partida, Jie Yin, Thomas J. Hoffmann, Wei Wang, K. Saidas Nair, and Eric Jorgenson
- Subjects
0301 basic medicine ,Candidate gene ,Aging ,medicine.medical_treatment ,Science ,General Physics and Astronomy ,Genome-wide association study ,Locus (genetics) ,Biology ,Genome-wide association studies ,General Biochemistry, Genetics and Molecular Biology ,Cataract ,Article ,Cohort Studies ,03 medical and health sciences ,Mice ,0302 clinical medicine ,Sex Factors ,Lens, Crystalline ,medicine ,Animals ,Humans ,Genetic Predisposition to Disease ,Gene ,Genetics ,Caspase 7 ,Mice, Knockout ,Molecular Epidemiology ,Multidisciplinary ,General Chemistry ,Cataract surgery ,Biobank ,Genetic architecture ,eye diseases ,Disease Models, Animal ,030104 developmental biology ,Logistic Models ,Gene Expression Regulation ,Ribonucleoproteins ,Genetic Loci ,Meta-analysis ,030221 ophthalmology & optometry ,Lens diseases ,Genome-Wide Association Study - Abstract
Cataract is the leading cause of blindness among the elderly worldwide and cataract surgery is one of the most common operations performed in the United States. As the genetic etiology of cataract formation remains unclear, we conducted a multiethnic genome-wide association meta-analysis, combining results from the GERA and UK Biobank cohorts, and tested for replication in the 23andMe research cohort. We report 54 genome-wide significant loci, 37 of which were novel. Sex-stratified analyses identified CASP7 as an additional novel locus specific to women. We show that genes within or near 80% of the cataract-associated loci are significantly expressed and/or enriched-expressed in the mouse lens across various spatiotemporal stages as per iSyTE analysis. Furthermore, iSyTE shows 32 candidate genes in the associated loci have altered gene expression in 9 different gene perturbation mouse models of lens defects/cataract, suggesting their relevance to lens biology. Our work provides further insight into the complex genetic architecture of cataract susceptibility., The genetic basis of cataract is not well understood. Here, the authors perform a genome-wide association multiethnic meta-analysis of cataract, finding 37 new loci and replicating known and new loci. They additionally perform sex-specific analyses, identifying new associations specific to women.
- Published
- 2021
22. Qki activates Srebp2-mediated cholesterol biosynthesis for maintenance of eye lens transparency
- Author
-
Yunfei Wang, Jiafu Long, Xin Zhou, Chenxi He, Hao Zhou, Jian Hu, Shaobo Wang, Fei Lan, Qiang Zhang, Yanjun Wei, Takashi Shingu, Qinling Mo, Ailiang Zeng, Hongtao Li, Seula Shin, and Yiwen Chen
- Subjects
0301 basic medicine ,genetic structures ,Science ,General Physics and Astronomy ,Gene Products, pol ,RNA polymerase II ,General Biochemistry, Genetics and Molecular Biology ,Article ,Cell Line ,Transcriptome ,03 medical and health sciences ,chemistry.chemical_compound ,Mice ,0302 clinical medicine ,Cataracts ,Downregulation and upregulation ,Transcription (biology) ,Chaperones ,Lens, Crystalline ,medicine ,Animals ,Humans ,RNA, Messenger ,Mice, Knockout ,Multidisciplinary ,biology ,Chemistry ,Cholesterol ,RNA-Binding Proteins ,General Chemistry ,medicine.disease ,Sterol ,eye diseases ,Cell biology ,Mice, Inbred C57BL ,Sterols ,030104 developmental biology ,medicine.anatomical_structure ,Lens (anatomy) ,biology.protein ,Lens diseases ,lipids (amino acids, peptides, and proteins) ,030217 neurology & neurosurgery ,Molecular Chaperones ,Sterol Regulatory Element Binding Protein 2 - Abstract
Defective cholesterol biosynthesis in eye lens cells is often associated with cataracts; however, how genes involved in cholesterol biosynthesis are regulated in lens cells remains unclear. Here, we show that Quaking (Qki) is required for the transcriptional activation of genes involved in cholesterol biosynthesis in the eye lens. At the transcriptome level, lens-specific Qki-deficient mice present downregulation of genes associated with the cholesterol biosynthesis pathway, resulting in a significant reduction of total cholesterol level in the eye lens. Mice with Qki depletion in lens epithelium display progressive accumulation of protein aggregates, eventually leading to cataracts. Notably, these defects are attenuated by topical sterol administration. Mechanistically, we demonstrate that Qki enhances cholesterol biosynthesis by recruiting Srebp2 and Pol II in the promoter regions of cholesterol biosynthesis genes. Supporting its function as a transcription co-activator, we show that Qki directly interacts with single-stranded DNA. In conclusion, we propose that Qki-Srebp2–mediated cholesterol biosynthesis is essential for maintaining the cholesterol level that protects lens from cataract development., Eye lens cells are highly enriched in cholesterol that sustains lens transparency, and disruption of cholesterol biosynthesis leads to cataracts. The authors show that cholesterol biosynthesis regulated by Qki is essential for maintenance of membrane integrity of lens cells and proper protein folding.
- Published
- 2021
23. Comparison of penetrating femtosecond laser-assisted astigmatic keratotomy and toric intraocular lens implantation for correction of astigmatism in cataract surgery
- Author
-
Kyoung Yoon Shin, Tae-Young Chung, Hoon Noh, Dong Hui Lim, and Young-Sik Yoo
- Subjects
Male ,genetic structures ,medicine.medical_treatment ,Intraocular lens ,0302 clinical medicine ,Lens Implantation, Intraocular ,Aged, 80 and over ,Lenses, Intraocular ,Multidisciplinary ,Middle Aged ,Laser assisted ,Refractive Errors ,Treatment Outcome ,Medicine ,Female ,Adult ,medicine.medical_specialty ,Biometry ,Corneal diseases ,Science ,Cataract Extraction ,Astigmatism ,Refraction, Ocular ,Article ,Comparative evaluation ,03 medical and health sciences ,Young Adult ,Ophthalmology ,medicine ,Humans ,Alpins method ,Aged ,Retrospective Studies ,Phacoemulsification ,business.industry ,Lasers ,Reproducibility of Results ,Cataract surgery ,medicine.disease ,Astigmatic keratotomy ,eye diseases ,030221 ophthalmology & optometry ,Lens diseases ,sense organs ,business ,Corneal astigmatism ,030217 neurology & neurosurgery - Abstract
This study tried to compare the clinical outcomes of femtosecond laser-assisted astigmatic keratotomy (FSAK) and toric intraocular lens (IOL) implantation for astigmatism correction and identify factors affecting the efficacy of FSAK and toric IOL implantation in astigmatism correction. This retrospective case series comprised patients with corneal astigmatism ranging between 0.5 D and 4.5 D. Patients underwent FSAK or toric IOL implantation for cataract treatment and correction of astigmatism at the Samsung Medical Center, a tertiary surgical center, between April 2016 and December 2018. All patients underwent examination before and at three months after the surgery for comparative evaluation of refractive astigmatism, corneal high order aberrations and irregularity index. The astigmatism correction was analyzed by the Alpins method. Subgroup analysis of preoperative factors was based on the extent of target-induced astigmatism (TIA), the degree of astigmatism, and astigmatism classification based on topography. Thirty-one eyes underwent toric IOL implantation and 35 eyes underwent FSAK. The refractive astigmatism was significantly decreased in both toric IOL (P = 0.000) and FSAK group (P = 0.003). The correction index (CI) of refractive astigmatism was 0.84 ± 0.39 in the toric IOL and 0.71 ± 0.60 in the FSAK group. There was no difference between the two groups (P = 0.337). The CI of the FSAK group was significantly lower than in the toric IOL group when TIA was more than 1.5 D (P = 0.006), when correcting against-the-rule (P = 0.017), and limbus-to-limbus astigmatism (P = 0.008). In conclusion, toric IOL implantation is an effective and safe procedure for correcting preoperative astigmatism in cataract surgery in the short-term observation.
- Published
- 2021
24. Visual outcomes of lens subluxation surgery with Cionni modified capsular tension rings in Marfan syndrome
- Author
-
Tianhui Chen, Jiahui Chen, Michael Deng, Yongxiang Jiang, Zexu Chen, and Min Zhang
- Subjects
0301 basic medicine ,Marfan syndrome ,Male ,medicine.medical_specialty ,Visual acuity ,Adolescent ,genetic structures ,Fibrillin-1 ,Science ,Population ,Lens Capsule, Crystalline ,Visual Acuity ,Glaucoma ,Gene mutation ,Article ,Ectopia Lentis ,Marfan Syndrome ,03 medical and health sciences ,0302 clinical medicine ,Lens Implantation, Intraocular ,Medicine ,Humans ,Lens subluxation ,Eye manifestations ,Ectopia lentis ,education ,Child ,Intraoperative Complications ,education.field_of_study ,Multidisciplinary ,Phacoemulsification ,business.industry ,Incidence (epidemiology) ,Lens Subluxation ,medicine.disease ,Surgery ,030104 developmental biology ,Risk factors ,Child, Preschool ,030221 ophthalmology & optometry ,Lens diseases ,Female ,medicine.symptom ,business - Abstract
Marfan syndrome (MFS) is a hereditary disease with an incidence of 0.3% in the general population. Approximately 60% of MFS patients with FBN1 gene mutation will suffer ectopia lentis (EL) from the age of 3. With the development of EL, severe loss of vision will accrue because of lens tilt and glaucoma. Cionni modified capsular tension rings (MCTR) has been applied in the surgery for EL in MFS patients. To evaluate visual acuity and safety of using MCTR during lens subluxation surgery in MFS patients, 66 MFS patients (110 eyes) were included in our study, with the mean duration of follow-up of 4.7 months (SD 1.76 months). The capsular bags were preserved in 101 eyes (91.81%) with MCTR implantation. There was an overall significant improvement in BCVA at 1-month follow-up which was maintained at 3 months. Multivariable linear regression revealed that older age at first visit was associated with greater postoperative BCVA at the 1-month follow-up (P = 0.007). A significant difference was found between different degrees of lens subluxation and the length of surgical time and complications. At follow-up, only two eyes (1.98%) were identified to have developed retinal detachments. In conclusion, better visual outcomes can be achieved when patients received an early operation with MCTR implantation.
- Published
- 2021
25. Long-term surgical outcomes of primary retropupillary iris claw intraocular lens implantation for the treatment of intraocular lens dislocation
- Author
-
Eun Young Choi, Jae Yong Han, Sung Soo Kim, Hyoung Jun Koh, Hyun Goo Kang, Chul Hee Lee, Suk Ho Byeon, and Min Kim
- Subjects
Pars plana ,Adult ,Male ,Intraocular pressure ,medicine.medical_specialty ,Visual acuity ,Intraocular Lens Dislocation ,Adolescent ,genetic structures ,medicine.medical_treatment ,Science ,Iris ,Vitrectomy ,Intraocular lens ,Article ,03 medical and health sciences ,Young Adult ,0302 clinical medicine ,Lens Implantation, Intraocular ,Ophthalmology ,medicine ,Humans ,Iris claw ,Macular edema ,Aged ,Retrospective Studies ,Aged, 80 and over ,Lenses, Intraocular ,Multidisciplinary ,business.industry ,Pupil ,Lens Subluxation ,Middle Aged ,medicine.disease ,eye diseases ,medicine.anatomical_structure ,Treatment Outcome ,Outcomes research ,030221 ophthalmology & optometry ,Medicine ,Lens diseases ,Female ,sense organs ,medicine.symptom ,business ,030217 neurology & neurosurgery ,Follow-Up Studies - Abstract
We aimed to investigate the efficacy and safety of primary retropupillary iris claw intraocular lens (R-IOL) implantation in patients with complete intraocular lens (IOL) dislocation. In this single-center retrospective case series, we reviewed the medical records of patients who underwent R-IOL implantation surgery with pars plana vitrectomy for the treatment of IOL dislocation between September 2014 and July 2019. The primary outcome was change in visual acuity (VA) up to 24 months postoperatively. The secondary outcomes included changes in intraocular pressure (IOP), refractive errors, and endothelial cell count (ECC) over the same period. Data of 103 eyes (98 patients) were analyzed. The mean uncorrected VA was significantly improved at one month postoperatively (− 0.69 logMAR, P P = 0.008) and ECC (− 333.4 cells/mm2, P = 0.027) significantly decreased one month post-surgery and remained stable thereafter. Postoperative mean spherical equivalents were similar to the prediction error throughout the follow-up period. IOP elevation (n = 8, 7.8%), cystoid macular edema (n = 4, 3.9%), and dislocation of the R-IOL (n = 10, 9.7%) were managed successfully. Overall, primary R-IOL implantation with pars plana vitrectomy is effective and safe for correcting IOL dislocation due to various causes.
- Published
- 2021
26. Common variants in SOX-2 and congenital cataract genes contribute to age-related nuclear cataract
- Author
-
Preeti Gupta, Maryam Hazly Hilmy, Jie Jin Wang, Jiemin Liao, Allan Fong, Maria K. Swift, Johanna M. Colijn, Paul Mitchell, Ya Xing Wang, Anita S Y Chan, Barbara E.K. Klein, Pirro G. Hysi, Jaeyoon Chung, Emily Y. Chew, Wanting Zhao, Yang Shen, Ava Grace Tan, Hengtong Li, Eranga N. Vithana, Gyungah Jun, Wenting Liu, Tin Aung, Qiao Fan, Yuan Shi, Ekaterina Yonova-Doing, Soon-Phaik Chee, Sudha K. Iyengar, Yik Ying Teo, Periasamy Sundaresan, Chiea Chuen Khor, Zheng Li, Kathryn P. Burdon, Miao Ling Chee, Yih Chung Tham, Christopher J Hammond, Xiaoran Chai, Kerrin S. Small, Queenie S. Tan, Jacqueline Chua, Jost B. Jonas, Astrid E. Fletcher, Alexessander Couto Alves, Pieter W.M. Bonnemaijer, Ravilla D. Ravindran, Mei Chin Lee, Milly S. Tedja, Robert P. Igo, Kristine E. Lee, Tien Y Wong, Xinyi Su, Caroline C W Klaver, Xueling Sim, Ching-Yu Cheng, Chaolong Wang, Lars G. Fritsche, Epidemiology, and Ophthalmology
- Subjects
0301 basic medicine ,Genotype ,genetic structures ,QH301-705.5 ,Medicine (miscellaneous) ,Genome-wide association study ,Disease ,Bioinformatics ,Polymorphism, Single Nucleotide ,Genome-wide association studies ,Cataract ,Article ,Sensory disorders Donders Center for Medical Neuroscience [Radboudumc 12] ,General Biochemistry, Genetics and Molecular Biology ,03 medical and health sciences ,All institutes and research themes of the Radboud University Medical Center ,0302 clinical medicine ,Genetic variation ,Humans ,Medicine ,Genetic Predisposition to Disease ,Allele ,Biology (General) ,Alleles ,Genetic Association Studies ,Genetic association ,business.industry ,SOXB1 Transcription Factors ,Genetic Variation ,medicine.disease ,eye diseases ,030104 developmental biology ,Age-related nuclear cataract ,030221 ophthalmology & optometry ,Congenital cataracts ,Lens diseases ,sense organs ,General Agricultural and Biological Sciences ,business ,Genome-Wide Association Study - Abstract
Nuclear cataract is the most common type of age-related cataract and a leading cause of blindness worldwide. Age-related nuclear cataract is heritable (h2 = 0.48), but little is known about specific genetic factors underlying this condition. Here we report findings from the largest to date multi-ethnic meta-analysis of genome-wide association studies (discovery cohort N = 14,151 and replication N = 5299) of the International Cataract Genetics Consortium. We confirmed the known genetic association of CRYAA (rs7278468, P = 2.8 × 10−16) with nuclear cataract and identified five new loci associated with this disease: SOX2-OT (rs9842371, P = 1.7 × 10−19), TMPRSS5 (rs4936279, P = 2.5 × 10−10), LINC01412 (rs16823886, P = 1.3 × 10−9), GLTSCR1 (rs1005911, P = 9.8 × 10−9), and COMMD1 (rs62149908, P = 1.2 × 10−8). The results suggest a strong link of age-related nuclear cataract with congenital cataract and eye development genes, and the importance of common genetic variants in maintaining crystalline lens integrity in the aging eye., Here, the authors report a multi-ethnic genome wide association meta-analysis of 12 studies from the International Cataract Genetics Consortium. They find six new loci associated with age-related nuclear cataract, in addition to replicating the association at CRYAA, and suggest a strong genetic link between age-related nuclear and congenital cataracts.
- Published
- 2020
27. Artificial intelligence manages congenital cataract with individualized prediction and telehealth computing
- Author
-
Lei Zhong, Zhuoling Lin, Yi Xiang, Xiaohang Wu, Hui Chen, Zhe Dong, Xin Liu, Xiyang Liu, Jing Li, Gang Tan, Xiaoyan Li, Fan Xu, Wenbin Wei, Yizhi Liu, Kai Huang, Min Li, Chuan Chen, Xinhua Liu, Xulin Zhang, Jiewei Jiang, Jian Lv, Jingjing Chen, Daoyao Nie, Haotian Lin, Qishan Zheng, Duoru Lin, Erping Long, Yi Zhu, Zhenzhen Liu, Meimei Dongye, Shiqi Ling, Wangting Li, Bo Yun, Weirong Chen, Liming Wang, Yifan Xiang, Chong Guo, Lanqin Zhao, Junhong Chen, Li Zhang, and Dongni Wang
- Subjects
Computer science ,business.industry ,Computer applications to medicine. Medical informatics ,education ,R858-859.7 ,Medicine (miscellaneous) ,Health Informatics ,Effective management ,Translational research ,Cloud computing ,Telehealth ,Health care economics ,lcsh:Computer applications to medicine. Medical informatics ,Article ,Computer Science Applications ,Scheduling (computing) ,Health Information Management ,Smartphone app ,lcsh:R858-859.7 ,Lens diseases ,Artificial intelligence ,Lens Diseases ,business - Abstract
A challenge of chronic diseases that remains to be solved is how to liberate patients and medical resources from the burdens of long-term monitoring and periodic visits. Precise management based on artificial intelligence (AI) holds great promise; however, a clinical application that fully integrates prediction and telehealth computing has not been achieved, and further efforts are required to validate its real-world benefits. Taking congenital cataract as a representative, we used Bayesian and deep-learning algorithms to create CC-Guardian, an AI agent that incorporates individualized prediction and scheduling, and intelligent telehealth follow-up computing. Our agent exhibits high sensitivity and specificity in both internal and multi-resource validation. We integrate our agent with a web-based smartphone app and prototype a prediction-telehealth cloud platform to support our intelligent follow-up system. We then conduct a retrospective self-controlled test validating that our system not only accurately detects and addresses complications at earlier stages, but also reduces the socioeconomic burdens compared to conventional methods. This study represents a pioneering step in applying AI to achieve real medical benefits and demonstrates a novel strategy for the effective management of chronic diseases.
- Published
- 2020
- Full Text
- View/download PDF
28. Objective quantification and spatial mapping of cataract with a Shack-Hartmann wavefront sensor
- Author
-
Csaba Tamás Holló, Máté Kurucz, Kinga Kránitz, Kata Miháltz, Illés Kovács, Gábor Erdei, Anita Csorba, and Zoltán Zsolt Nagy
- Subjects
0301 basic medicine ,genetic structures ,Computer science ,lcsh:Medicine ,Imaging techniques ,Characterization and analytical techniques ,Pupil ,Article ,Cataract ,law.invention ,03 medical and health sciences ,0302 clinical medicine ,Optics ,Medical research ,Optical physics ,Corneal Opacity ,law ,Calibration ,Humans ,lcsh:Science ,Shack–Hartmann wavefront sensor ,Multidisciplinary ,Scattering ,business.industry ,lcsh:R ,Imaging and sensing ,Wavefront sensor ,Superluminescent diode ,eye diseases ,Lens (optics) ,030104 developmental biology ,Cardinal point ,030221 ophthalmology & optometry ,Disease Progression ,Lens diseases ,lcsh:Q ,sense organs ,business - Abstract
Based on wavefront sensor images an objective and quantitative method is presented for characterising cataract. By separating direct and scattered light in the focal plane of the microlenses, the new procedure is able to make two-dimensional maps of the spatial variation of scattering properties in the crystalline lens, and also provides a single figure descriptive for the whole eye. The developed evaluation algorithm successfully quantifies cataract, especially that of nuclear type. To demonstrate its operation, a custom-built measurement setup was constructed using a Shack-Hartmann wavefront sensor with $$40 \times 32$$40×32 microlenses to capture 12-bit images of the pupil plane, and a superluminescent diode of 830 nm wavelength as a light source. Slit-lamp clinical measurements served as reference for calibration and to estimate the accuracy of the new method. The tests were carried out on 78 eyes with cataract in different progression state ranging from healthy to above 5 on the LOCS III scale. The residual error of the calibration (i.e. the standard deviation of difference between clinical reference and our algorithmic characterisation) turned out to be $$\pm 0.29$$±0.29 category on the LOCS III N scale, which approximates the $$\pm 0.33$$±0.33 precision of classic cataract measurements carried out with the greatest care.
- Published
- 2020
- Full Text
- View/download PDF
29. The incidence and management of persistent cystoid macular oedema following uncomplicated cataract surgery—a Scottish Ophthalmological Surveillance Unit study
- Author
-
David Lockington, Barny Foot, Ore-Oluwa Erikitola, and Thomas Siempis
- Subjects
Male ,medicine.medical_specialty ,Visual acuity ,genetic structures ,Epidemiology ,medicine.medical_treatment ,Cataract Extraction ,Cataract ,Macular Edema ,Article ,Ophthalmology ,Diabetes mellitus ,medicine ,Humans ,Initial treatment ,Aged ,business.industry ,Incidence ,Incidence (epidemiology) ,Mean age ,Cataract surgery ,medicine.disease ,eye diseases ,Scotland ,Cystoid macular oedema ,Lens diseases ,medicine.symptom ,business ,Acetazolamide ,medicine.drug - Abstract
Purpose Post-operative cystoid macular oedema (CMO) can cause deterioration of vision following routine cataract surgery. The incidence of persistent CMO (pCMO; defined as CMO present after 3 months) following uncomplicated surgery is uncertain. We wished to identify the incidence, management and visual outcomes of such patients. Methods A Scottish Ophthalmological Surveillance Unit (SOSU) questionnaire was sent monthly to every ophthalmic specialist in Scotland over an 18-month period from 1st January 2018 asking them to report all new patients with pCMO confirmed on OCT scanning following uncomplicated cataract surgery. A follow-up questionnaire was sent 9 months after initial presentation. Results Fourteen cases of pCMO were reported, giving an incidence of 2.2 cases of pCMO per 10,000 uncomplicated cataract surgeries. Mean age was 74.9 years (SD 10.2; range 44–86) with a male preponderance (72.7%). Two patients developed pCMO in each eye. Six cases (46.2%) had hypertension and one had diabetes. Three eyes required intracameral adjuncts (two iris hooks, one intracameral phenylephrine). Postoperative visual acuity (VA) at 3 months was logMAR 0.48 (0.2–0.8). Average mean central retinal thickness (CRT) at 3 months was 497microns (270–788). The most common initial treatment comprised topical steroids and topical NSAIDs (61.5%). Other management strategies included systemic steroids, intravitreal steroids and oral acetazolamide. At 1-year post-op, mean VA was logMAR 0.18 (0.1–0.3) with average mean CRT of 327microns (245–488). Conclusions We identified a low incidence of pCMO following uncomplicated cataract surgery in Scotland (0.02%), with inconsistent and variable management regimes. A nationally agreed treatment protocol is required.
- Published
- 2020
- Full Text
- View/download PDF
30. Comparison of methods to experimentally induce opacification and elasticity change in ex vivo porcine lenses
- Author
-
Andreas Schlatter, Martin Kronschläger, Manuel Ruiss, Thomas Dechat, and Oliver Findl
- Subjects
Triamcinolone acetonide ,genetic structures ,Swine ,Science ,Sodium ,chemistry.chemical_element ,Cataract ,Article ,law.invention ,In vitro model ,chemistry.chemical_compound ,law ,Lens, Crystalline ,medicine ,Animals ,Elasticity (economics) ,Microwaves ,Hydrogen peroxide ,Multidisciplinary ,Osmolar Concentration ,Organ Size ,eye diseases ,Culture Media ,Experimental models of disease ,Lens (optics) ,Disease Models, Animal ,chemistry ,Medicine ,Hypertonic sodium chloride ,Lens diseases ,sense organs ,Ex vivo ,Biomedical engineering ,medicine.drug - Abstract
At the moment, cataract, which is the opacification of the eye’s lens, can only be treated by surgery. In order to develop and test new pharmacological treatment strategies for the disease, there is a need for an appropriate in vitro model using ex vivo animal lenses. In this study, porcine lenses were incubated in either culture medium, glucose, triamcinolone acetonide, sodium chloride, hydrogen peroxide, sodium selenite, neutral buffered formalin, or were exposed to microwave heating to experimentally induce lens opacification. Changes in the lens morphology, weight, size, and elasticity were monitored 7 days after treatment. The fastest induction of dense opacification was seen in lenses exposed to sodium chloride, neutral buffered formalin, and microwave heating. No change in the size and weight of the lenses were detected, whereas loss in elasticity could be detected in lenses treated with formalin solution or microwave heating. Thus, neutral buffered formalin- and microwave-treated ex vivo porcine lenses seem to be a suitable model for mature cataracts, whereas hypertonic sodium chloride may be useful for studies on osmolarity-induced lens opacification.
- Published
- 2021
- Full Text
- View/download PDF
31. Electron microscopy analysis of femtosecond laser-assisted capsulotomy before and after lens fragmentation
- Author
-
Wolfgang J. Mayer, Andreas Ohlmann, Anna Schuh, Siegfried Priglinger, Thomas Kohnen, and Mehdi Shajari
- Subjects
Aged, 80 and over ,Male ,Multidisciplinary ,genetic structures ,Science ,Cataract Extraction ,Middle Aged ,eye diseases ,Article ,Cataract ,Lens, Crystalline ,Medicine ,Anterior Capsule of the Lens ,Humans ,Lens diseases ,Female ,sense organs ,Laser Therapy ,Eye diseases ,Aged - Abstract
Studying anterior lens capsule cutting edge profiles from femtosecond laser-assisted capsulotomy procedures performed before and after lens fragmentation. Twenty eyes (10 patients) with age-related cataract underwent femtosecond laser-assisted surgery (FLACS) using the Ziemer Z8 platform. First step of laser surgery was either capsulotomy (group first) or fragmentation (group second). One eye of each patient was assigned randomly, the second eye treated with the different sequence of procedures. After anterior capsule removal, tissue was fixed in cacodylate-buffered solution and cutting-edge profiles were analysed using scanning electron microscopy (SEM). All cases had cataract grade 2 and 3 based on LOCS III grading. SEM analysis showed more smooth edges in the first group, especially in cases with pseudoexfoliation (P = 0.037); more tags and bridges and a significant number of staggered cutting patterns (7 out of 10 cases) in the second group. All cases evolved the same microgroves with “valleys and mountains “ as signs of the photodisruption process. Femtosecond laser capsulotomy should be performed before lens fragmentation minimizing the rate of cutting errors. Especially in eyes with advanced cataract, as intracapsular pressure may increase due to lens fragmentation without anterior capsular opening.
- Published
- 2021
32. Pupil dynamics after in-the-bag versus anterior and retropupillary iris-fixated intraocular lens implantation
- Author
-
Yanxiu Sun, Gerd U. Auffarth, Maximilian Hammer, Timur M. Yildirim, and Ramin Khoramnia
- Subjects
Adult ,Male ,medicine.medical_specialty ,Pseudophakia ,genetic structures ,Science ,medicine.medical_treatment ,Visual Acuity ,Iris ,Intraocular lens ,Aphakia ,Article ,Pupil ,Constriction ,Lens Implantation, Intraocular ,Ophthalmology ,Myopia ,medicine ,Humans ,Scotopic vision ,Iris (anatomy) ,Eye diseases ,Aged ,Fixation (histology) ,Subluxation ,Pupil disorders ,Multidisciplinary ,business.industry ,Middle Aged ,medicine.disease ,eye diseases ,Hyperopia ,medicine.anatomical_structure ,Medicine ,Lens diseases ,Female ,sense organs ,business - Abstract
An Intraocular Lens (IOL) fixated on the iris either anteriorly, as a phakic IOL, or posteriorly, as an aphakic IOL, can influence pupil motility. In this interventional case series study, we evaluated pupil size under different levels of illumination (scotopic = 0.04 lx, low-mesopic = 0.4 lx and high-mesopic = 4 lx) for anterior iris-claw IOL fixation for correcting myopia or hyperopia (IFPH), retropupillary iris-claw IOL fixation to correct aphakia or as treatment for late in-the-bag IOL dislocation/subluxation (IFRP), and capsular-fixation IOL in-the-bag implantation (IB). Pupil size was measured preoperatively for the IFPH- and IB-group as well as 6 months after surgery for all groups. We analyzed a total of 70 eyes: 22 eyes of 11 patients with phakic IOLs, 22 eyes of 20 patients in the IFRP group and 26 eyes of 13 patients in the IB group. Both IFPH and IB showed a smaller postoperative scotopic pupil size, compared with the preoperative values. When compared to postoperative values of IB and IFPH, IFRP showed a significantly smaller postoperative scotopic pupil size (IFPH: 5.89 ± 0.83 mm, IFRP: 4.37 ± 0.83 mm, IB: 5.34 ± 0.98 mm, p
- Published
- 2021
- Full Text
- View/download PDF
33. Modeling congenital cataract in vitro using patient-specific induced pluripotent stem cells
- Author
-
Shengjie Hao, Jiliang He, Ke Yao, Lifang Zhang, Qiaomei Tang, Junfeng Ji, Bing Lu, Houfa Yin, Jiayong Li, Danni Lyu, Andras Nagy, Zhijian Chen, Zhenwei Qin, Yong-Bin Yan, Shuang Ni, and Qiuli Fu
- Subjects
genetic structures ,Visual impairment ,Biomedical Engineering ,Medicine (miscellaneous) ,Bioinformatics ,Article ,Cataracts ,medicine ,Lentoid ,Induced pluripotent stem cell ,Pathological ,business.industry ,Childhood blindness ,Cell Biology ,medicine.disease ,In vitro ,eye diseases ,Stem-cell research ,Experimental models of disease ,Congenital cataracts ,Medicine ,Lens diseases ,sense organs ,medicine.symptom ,business ,Developmental Biology - Abstract
Congenital cataracts are the leading cause of childhood blindness. To date, surgical removal of cataracts is the only established treatment, but surgery is associated with multiple complications, which often lead to visual impairment. Therefore, mechanistic studies and drug-candidate screening have been intrigued by the aims of developing novel therapeutic strategies. However, these studies have been hampered by a lack of an appropriate human-disease model of congenital cataracts. Herein, we report the establishment of a human congenital cataract in vitro model through differentiation of patient-specific induced pluripotent stem cells (iPSCs) into regenerated lenses. The regenerated lenses derived from patient-specific iPSCs with known causative mutations of congenital cataracts (CRYBB2 [p. P24T] and CRYGD [p. Q155X]) showed obvious opacification that closely resembled that seen in patients’ cataracts in terms of opacification severity and disease course accordingly, as compared with lentoid bodies (LBs) derived from healthy individuals. Increased protein aggregation and decreased protein solubility corresponding to the patients’ cataract severity were observed in the patient-specific LBs and were attenuated by lanosterol treatment. Taken together, the in vitro model described herein, which recapitulates patient-specific clinical manifestations of congenital cataracts and protein aggregation in patient-specific LBs, provides a robust system for research on the pathological mechanisms of cataracts and screening of drug candidates for cataract treatment.
- Published
- 2021
34. Use of Techniques for Scleral and Iris Fixation in Secondary Implantation of Intraocular Lenses
- Author
-
Joao Crispim Moraes Lima Ribeiro, Volney Anderson Castaldelli, Giulia de Carvalho Firmino, Gabriel Bezerra Castaldelli, and Rafael de Souza Costa
- Subjects
medicine.medical_specialty ,Visual acuity ,genetic structures ,medicine.medical_treatment ,Visual Acuity ,Iris ,Aphakia ,Surgical methods ,Cellular and Molecular Neuroscience ,Fixation (surgical) ,Lens Implantation, Intraocular ,Ophthalmology ,medicine ,Humans ,Lenses, Intraocular ,Subluxation ,business.industry ,Suture Techniques ,General Medicine ,Cataract surgery ,medicine.disease ,eye diseases ,Sensory Systems ,Sclera ,medicine.anatomical_structure ,Lens Diseases ,Intraocular lenses ,sense organs ,medicine.symptom ,business - Abstract
Scleral and iris fixation of intraocular lenses (IOL) are useful in the treatment of surgical or traumatic aphakia, luxation, and subluxation of IOL if the patient does not present appropriate capsular support. However, there is no consensus in the literature about which of these 2 methods is safer and better. The authors performed a literature review searching the main postoperative outcomes obtained with the use of each surgical method. Scleral and iris fixation of IOL are efficient in correction of the patients’ visual acuity, even though each technique presents distinct complications which depend especially on the experience of the surgeon with the performed surgical method. It is important to understand that individuals submitted to scleral or iris fixation present previous preoperative complications in their eyes. Besides, both procedures are very complex, involving intense manipulation of the eye globe. The success rate of these surgical techniques is highly variable and has a close relation to the preoperative conditions of the patient’s eye and the improvement of the surgeon’s learning curve.
- Published
- 2020
- Full Text
- View/download PDF
35. Site of clear corneal incision in cataract surgery and its effects on surgically induced astigmatism
- Author
-
Choun-Ki Joo and Junjie Piao
- Subjects
Male ,medicine.medical_specialty ,Corneal diseases ,medicine.medical_treatment ,lcsh:Medicine ,Cataract Extraction ,Article ,Cornea ,03 medical and health sciences ,Postoperative Complications ,0302 clinical medicine ,Lens Implantation, Intraocular ,Clear corneal incision ,Ophthalmology ,medicine ,Humans ,Postoperative Period ,Prospective Studies ,030212 general & internal medicine ,lcsh:Science ,Aged ,Phacoemulsification ,Multidisciplinary ,Surgical approach ,business.industry ,lcsh:R ,Astigmatism ,Middle Aged ,Cataract surgery ,Refractive errors ,Meridian (perimetry, visual field) ,030221 ophthalmology & optometry ,Female ,Lens diseases ,Surgically induced astigmatism ,lcsh:Q ,sense organs ,business - Abstract
Clear corneal incision (CCI) is a commonly used surgical approach in cataract surgery. In this prospective study, we evaluated the effect of CCI site on surgically induced astigmatism (SIA) and other postoperative astigmatic changes. CCIs were constructed based on the steep meridian of the total corneal refractive power in the 4.0-mm-zone (TCRP4.0), and patients were divided into four groups: temporal, superotemporal, superonasal, and superior according to the site of the incision. TCRP4.0 analysis demonstrated a statistically significant reduction of astigmatism with superior incisions (P 2 = 1.977), superotemporal (Hotelling T2 = 0.544), superonsal (Hotelling T2 = 1.066), and superior incision groups (Hotelling T2 = 1.134) (all P
- Published
- 2020
- Full Text
- View/download PDF
36. Intraocular Lens power calculation after laser refractive surgery: A Meta-Analysis
- Author
-
Ke Yao, Xinyi Chen, Hanle Wang, Hui Chen, and Zhi Fang
- Subjects
Adult ,medicine.medical_specialty ,Corneal diseases ,Mean squared prediction error ,medicine.medical_treatment ,lcsh:Medicine ,Keratomileusis ,Intraocular lens ,Article ,law.invention ,03 medical and health sciences ,0302 clinical medicine ,law ,Refractive surgery ,Ophthalmology ,medicine ,Humans ,030212 general & internal medicine ,lcsh:Science ,Mathematics ,Lenses, Intraocular ,Multidisciplinary ,Lasers ,lcsh:R ,Middle Aged ,Laser ,Photorefractive keratectomy ,Refractive Surgical Procedures ,Meta-analysis ,030221 ophthalmology & optometry ,Lens diseases ,Intraocular lens power calculation ,lcsh:Q ,Publication Bias - Abstract
There are an increasing number of people who have had refractive surgery now developing cataract. To compare the accuracy of different intraocular lens (IOL) power calculation formulas after laser refractive surgery (photorefractive keratectomy or laser in situ keratomileusis), a comprehensive literature search of PubMed and EMBASE was conducted to identify comparative cohort studies and case series comparing different formulas: Haigis-L, Shammas-PL, SRK/T, Holladay 1 and Hoffer Q. Seven cohort studies and three observational studies including 260 eyes were identified. There were significant differences when Hoffer Q formula compared with SRK/T, Holladay 1. Holladay 1 formula produced less prediction error than SRK/T formula in double-K method. Hoffer Q formula performed best among SRK/T and Holladay 1 formulas in total and single-K method. In eyes with previous data, it is recommended to choose double-K formula except SRK/T formula. In eyes with no previous data, Haigis-L formula is recommended if available, if the fourth formula is unavailable, single-k Hoffer Q is a good choice.
- Published
- 2020
- Full Text
- View/download PDF
37. Modelling floppy iris syndrome and the impact of pupil size and ring devices on iris displacement
- Author
-
Li Cai, Xiaoyu Luo, Nan Qi, Chenglei Wang, Zhaokun Wang, David Lockington, Hui Tang, Boris Malyugin, and Kanna Ramaesh
- Subjects
Ring device ,medicine.medical_specialty ,Technology ,Computer science ,Iris ,urologic and male genital diseases ,Displacement (vector) ,Pupil ,Article ,03 medical and health sciences ,0302 clinical medicine ,Pupil Disorders ,Ophthalmology ,medicine ,Pupillary response ,Floppy iris syndrome ,Humans ,cardiovascular diseases ,Iris (anatomy) ,Intraoperative Complications ,Ring (mathematics) ,Phacoemulsification ,urogenital system ,fungi ,Pupil size ,female genital diseases and pregnancy complications ,medicine.anatomical_structure ,Iris Diseases ,030221 ophthalmology & optometry ,Lens diseases ,030217 neurology & neurosurgery - Abstract
Introduction The aim of this paper was to further develop a previously described finite element model which equates clinical iris billowing movements with mechanical buckling behaviour, simulating floppy iris syndrome. We wished to evaluate the impact of pupil dilation and mechanical devices on normal iris and floppy iris models. Methods Theoretical mathematical modelling and computer simulations were used to assess billowing/buckling patterns of the iris under loading pressures for the undilated and dilated normal iris, the undilated and dilated floppy iris, and additionally with a mechanical ring device. Results For the normal iris, billowing/buckling occurred at a critical pressure of 19.92 mmHg for 5 mm pupil size, which increased to 28.00 mmHg (40.56%) with a 7 mm pupil. The Malyugin ring device significantly increased critical initiating buckling pressures in the normal iris scenario, to 34.58 mmHg (73.59%) for 7 mm ring with boundary conditions I (BC I) and 34.51 mmHg (73.24%) with BC II. For the most floppy iris modelling (40% degradation), initiating buckling value was 18.04 mmHg (−9.44%), which increased to 28.39 mmHg (42.52%) with the 7 mm ring. These results were much greater than for normal undilated iris without restrictive mechanical expansion (19.92 mmHg). Conclusion This simulation demonstrates that pupil expansion devices inhibit iris billowing even in the setting of floppy iris syndrome. Our work also provides a model to further investigate the impact of pupil size or pharmacological interventions on anterior segment conditions affected by iris position.
- Published
- 2020
38. The Hull Anterior Vitrectomy Simulation System (HAVSS): a validated novel simulation for training in the management of intra-operative vitreous loss
- Author
-
James R. Innes and Anindita Hom-Choudhury
- Subjects
medicine.medical_specialty ,Intra operative ,Triamcinolone acetonide ,Eye Diseases ,business.industry ,medicine.medical_treatment ,Vitrectomy ,Vitreous loss ,Simulation system ,Triamcinolone Acetonide ,Article ,Ophthalmology ,medicine ,Humans ,Lens Diseases ,business ,Glucocorticoids ,medicine.drug - Abstract
OBJECTIVES: To design and validate a feasible simulation to address an identified training gap in the management of intraoperative vitreous loss. METHODS: Our simulation consists of a two-part non-toxic mixture that polymerises upon contact within a silicone training eye, to resemble the appearance of vitreous after staining with triamcinolone. This gel can be cut and aspirated with an anterior vitrectomy probe. Experienced consultant ophthalmic surgeons were invited to assess the simulation and anonymously complete validity questionnaires. RESULTS: Seven senior surgeons participated. Four (57%) strongly agreed and three (43%) agreed that the tissue behaved like vitreous. Six (86%) strongly agreed and one (14%) agreed that instrument handling was realistic. Three (43%) strongly agreed and four (57%) agreed that simulated triamcinolone staining was realistic. Four (57%) strongly agreed and three (43%) agreed that the simulation was visually convincing. Six (86%) strongly agreed and one (14%) agreed that this simulation is useful for training. No participants disagreed with any validity statements. CONCLUSIONS: This novel simulation of anterior vitrectomy has good face and content validity, with unanimous agreement among experienced surgeons of its utility for training in the management of intraoperative vitreous loss.
- Published
- 2020
- Full Text
- View/download PDF
39. Outcomes and complications of iris-fixated intraocular lenses in cases with inadequate capsular support and complex ophthalmic history
- Author
-
Yassine J. Daoud, Osama M. Mustafa, Jacob T. Cox, Daliya Dzhaber, and Jing Tian
- Subjects
medicine.medical_specialty ,Intraocular pressure ,genetic structures ,Visual Acuity ,Iris ,Aphakia ,Article ,03 medical and health sciences ,Postoperative Complications ,0302 clinical medicine ,Lens Implantation, Intraocular ,Ophthalmology ,medicine ,Humans ,Ectopia lentis ,Retrospective Studies ,Lenses, Intraocular ,Subluxation ,business.industry ,Suture Techniques ,High myopia ,medicine.disease ,eye diseases ,Treatment Outcome ,Intraocular lenses ,Vision disorders ,Concomitant ,030221 ophthalmology & optometry ,Lens diseases ,sense organs ,Epiretinal membrane ,business ,030217 neurology & neurosurgery - Abstract
Background To report the indications, visual outcomes, and intra-operative and post-operative complications of iris-sutured posterior chamber intraocular lens (IOL) in eyes with inadequate capsular support and complex ocular history. Methods A chart review and data analysis of eyes that underwent iris fixation of posterior chamber (PC) IOL for correction of aphakia, dislocated and subluxed IOLs, ectopia lentis, and IOL exchange. Data included clinical risk factors, associated eye conditions, previous surgeries, and concomitant procedures. The pre-operative and post-operative vision, manifest refraction, endothelial cell density, intraocular pressure (IOP), as well as intra-operative and post-operative complications were also recorded. Results One hundred and seventeen eyes from 114 patients were examined with a mean follow-up of 22.4 months. The most common identifiable predisposing risk factor was high myopia in 23 eyes. A significant improvement in uncorrected and best corrected visual acuity compared with baseline was observed. The most common post-operative complications included recurrent IOL subluxation in 16 (13.7%) eyes, IOP spike in 7 (5.9%) eyes, cystoid macular oedema in 5 (4.3%) eyes, and epiretinal membrane formation in 4 (3.4%) eyes. There was one (0.85%) case of sterile endophthalmitis. Conclusions Iris suture fixation of PC IOLs is a good treatment option for eyes with inadequate capsular support and complex ocular history.
- Published
- 2020
- Full Text
- View/download PDF
40. Effectiveness of intraoperative intraocular lens use on improving surgical safety for dense cataract phacoemulsification: a randomized controlled trial
- Author
-
Yunxin Chen, Mingbing Zeng, Rong Wang, Chengwu Yang, Bing Cheng, and Xialin Liu
- Subjects
Male ,medicine.medical_specialty ,genetic structures ,medicine.medical_treatment ,Visual Acuity ,lcsh:Medicine ,Intraocular lens ,Cataract Extraction ,Article ,Cataract ,law.invention ,Cataract extraction ,03 medical and health sciences ,0302 clinical medicine ,Lens Implantation, Intraocular ,Randomized controlled trial ,law ,Surgical safety ,Ophthalmology ,Lens, Crystalline ,medicine ,Humans ,lcsh:Science ,Aged ,Lenses, Intraocular ,Phacoemulsification ,Multidisciplinary ,Eye, Artificial ,business.industry ,Ultrasound ,lcsh:R ,Endothelial Cells ,eye diseases ,Posterior capsular rupture ,Vision disorders ,030220 oncology & carcinogenesis ,Relative risk ,030221 ophthalmology & optometry ,Lens diseases ,Female ,lcsh:Q ,sense organs ,business - Abstract
We designed this study to assess if surgical safety can be improved by intraoperative use of intraocular lens (IOL) for cataract phacoemulsification. We performed phacoemulsification cataract removal on 401 patients. We randomly assigned these patients into three groups: the standard setting (Group I, n = 134), with reduced vacuum and flow rate (Group II, n = 137), and with IOL insertion before the last quadrant was emulsified with standard setting (Group III, n = 130). The primary outcomes included the risk of posterior capsular rupture (PCR), ultrasound time, energy, and complications. The secondary outcomes included central corneal thickness (CCT), CCT changes, endothelial cells (ETC) counting, ETC loss, and the best corrected distance visual acuity (BCVA) measured on day 1, day 7 and day 30. If PCR occurred, we emulsified the residual lens materials after insertion of IOL and clean of the prolapsed vitreous. We found that the risk of PCR in Group III (0/130) was lower than Group I (9/134, corrected relative risk (RR) = 18.44, 95% CI: 1.08–313.56) and Group II (3/137, corrected RR = 6.64, 95% CI: 0.35–27.41). Group III showed better BCVA on day 1 and 7, less ECC loss on day 7 and 30, and less CCT increase on day 1 and 7. No cases converted to extracapsular cataract extraction. No residual lens materials misdirected into vitreous cavity. Intraoperative use of IOL can improve surgical safety for dense cataract phacoemulsification.
- Published
- 2020
- Full Text
- View/download PDF
41. A FBN1 variant manifesting as non-syndromic ectopia lentis with retinal detachment: clinical and genetic characteristics
- Author
-
Andrew Green, David J Keegan, Michael O'Keefe, Kirk Stephenson, Adrian Dockery, and G. Jane Farrar
- Subjects
musculoskeletal diseases ,Adult ,0301 basic medicine ,Retinal degeneration ,congenital, hereditary, and neonatal diseases and abnormalities ,medicine.medical_specialty ,Fibrillin-1 ,Fibrillins ,Article ,Ectopia Lentis ,Marfan Syndrome ,03 medical and health sciences ,Dysgenesis ,0302 clinical medicine ,Informed consent ,Ophthalmology ,medicine ,Humans ,Eye manifestations ,Ectopia lentis ,Disease genetics ,business.industry ,Microfilament Proteins ,Retinal Detachment ,Retinal detachment ,Hereditary eye disease ,medicine.disease ,Institutional review board ,eye diseases ,Retinal diseases ,Pedigree ,Phenotype ,030104 developmental biology ,Increased risk ,Mutation ,030221 ophthalmology & optometry ,Lens diseases ,business ,Non syndromic - Abstract
Background/objectives Fibrillin-1 (FBN1) mutations cause connective tissue dysgenesis the main ocular manifestation being ectopia lentis (EL), which may be syndromic or non-syndromic. We describe a pedigree with a FBN1 mutation causing non-syndromic EL with retinal detachment (RRD) and their management. Subjects/methods Patients with familial EL with RRD were invited to participate (vitreoretinopathy branch of Target 5000, the Irish inherited retinal degeneration study). All patients signed full informed consent. The study was approved by the Institutional Review Board of the Mater Hospital, Dublin and abided by the Declaration of Helsinki. Results Seven adults were affected with bilateral EL. All subjects had RRD with bilateral non-synchronous RRD in 57%. Conclusions The FBN1 variant described herein confers an increased risk of both EL and RRD and can now be upgraded to ‘pathogenic’ ACMG status.
- Published
- 2019
- Full Text
- View/download PDF
42. Early Postoperative Rotational stability and its related factors of a single-piece acrylic toric intraocular lens
- Author
-
Suhong He, Xingdi Wu, Shuyi Li, Qianyin Zheng, Xi Li, Xiang Chen, and Wen Xu
- Subjects
medicine.medical_specialty ,Visual acuity ,genetic structures ,medicine.medical_treatment ,Visual Acuity ,Intraocular lens ,Astigmatism ,Refraction, Ocular ,Article ,03 medical and health sciences ,0302 clinical medicine ,Lens Implantation, Intraocular ,Ophthalmology ,medicine ,Humans ,Prospective Studies ,Capsulorhexis ,Retrospective Studies ,Lenses, Intraocular ,Related factors ,Phacoemulsification ,business.industry ,medicine.disease ,eye diseases ,Risk factors ,Outcomes research ,030221 ophthalmology & optometry ,Lens diseases ,medicine.symptom ,business ,Rotational stability ,Corneal astigmatism ,030217 neurology & neurosurgery - Abstract
Purpose In the present study, we aimed to evaluate the early postoperative rotational stability of TECNIS toric intraocular lens (IOL) and analyse its correlation with preoperative and intraoperative parameters. Methods A total of 102 eyes from 87 cataract patients who underwent implantation of TECNIS toric IOL during July 2016 to November 2017 were enrolled in this retrospective study. Preoperative parameters including corneal astigmatism, axial length (AL), lens thickness (LT), anterior chamber depth (ACD) and sulcus-to-sulcus (STS), were determined. The area of capsulorhexis was measured with Rhinoceros 5.0 software. The follow-up examinations including the residual astigmatism (RAS) and postoperative toric IOL axis, were performed at 1 month and 3 months after surgery. Results RAS was −0.84 ± 0.88 D at 1 month and −0.81 ± 0.89 D at 3 months after surgery. The rotation of toric IOL at 3 months was 4.83 ± 3.65°. The Pearson’s r of ACD, horizontal and vertical STS, and toric IOL target axis was 0.011, 0.039, 0.045 and 0.082. The toric IOL rotation was positively correlated with the area of capsulorhexis (r = 0.522, P = 0.0003), LT (r = 0.288, P = 0.003) and AL (r = 0.259, P = 0.009). As for the area of capsulorhexis, the regressive equation was: y = 0.682 × −13.105, demonstrating that the diameter of capsulorhexis should be controlled within 5.8 mm to maintain the toric IOL rotation within 5.0°. Conclusions TECNIS toric IOLs possessed great early postoperative rotational stability. The area of capsulorhexis, AL and LT were positively correlated with postoperative rotational stability. A capsulorhexis within 5.8 mm had an important significance in improving rotational stability.
- Published
- 2019
- Full Text
- View/download PDF
43. Failure of Oxysterols Such as Lanosterol to Restore Lens Clarity from Cataracts
- Author
-
K. Krishna Sharma, Peter F. Kador, Ashutosh S. Phadte, Marjorie F. Lou, Puttur Santhoshkumar, Damian M. Daszynski, and Haizhen A. Zhong
- Subjects
0301 basic medicine ,ATPase ,lcsh:Medicine ,Ouabain ,Cataract ,Article ,Lens protein ,03 medical and health sciences ,chemistry.chemical_compound ,Lanosterol ,0302 clinical medicine ,Cataracts ,Lens, Crystalline ,medicine ,polycyclic compounds ,Animals ,Humans ,lcsh:Science ,Ion transporter ,Multidisciplinary ,biology ,Chemistry ,lcsh:R ,Wild type ,alpha-Crystallin B Chain ,Oxysterols ,medicine.disease ,Crystallins ,In vitro ,Hydroxycholesterols ,eye diseases ,Cell biology ,Rats ,Disease Models, Animal ,030104 developmental biology ,Mechanisms of disease ,biology.protein ,Lens diseases ,lipids (amino acids, peptides, and proteins) ,lcsh:Q ,sense organs ,030217 neurology & neurosurgery ,medicine.drug ,Molecular Chaperones - Abstract
The paradigm that cataracts are irreversible and that vision from cataracts can only be restored through surgery has recently been challenged by reports that oxysterols such as lanosterol and 25-hydroxycholesterol can restore vision by binding to αB-crystallin chaperone protein to dissolve or disaggregate lenticular opacities. To confirm this premise, in vitro rat lens studies along with human lens protein solubilization studies were conducted. Cataracts were induced in viable rat lenses cultured for 48 hours in TC-199 bicarbonate media through physical trauma, 10 mM ouabain as Na+/K+ ATPase ion transport inhibitor, or 1 mM of an experimental compound that induces water influx into the lens. Subsequent 48-hour incubation with 15 mM of lanosterol liposomes failed to either reverse these lens opacities or prevent the further progression of cataracts to the nuclear stage. Similarly, 3-day incubation of 47-year old human lenses in media containing 0.20 mM lanosterol or 60-year-old human lenses in 0.25 and 0.50 mM 25-hydroxycholesterol failed to increase the levels of soluble lens proteins or decrease the levels of insoluble lens proteins. These binding studies were followed up with in silico binding studies of lanosterol, 25-hydroxycholesterol, and ATP as a control to two wild type (2WJ7 and 2KLR) and one R120G mutant (2Y1Z) αB-crystallins using standard MOETM (Molecular Operating Environment) and Schrödinger’s Maestro software. Results confirmed that compared to ATP, both oxysterols failed to reach the acceptable threshold binding scores for good predictive binding to the αB-crystallins. In summary, all three studies failed to provide evidence that lanosterol or 25-hydroxycholesterol have either anti-cataractogenic activity or bind aggregated lens protein to dissolve cataracts.
- Published
- 2019
- Full Text
- View/download PDF
44. Repercusiones oculares del Síndrome de Alport: A propósito de dos casos
- Author
-
Alex Jones, Magdalena Reyes, Manuel Gallegos, Ignacio Díaz, and Sergio Zacharias
- Subjects
congenital, hereditary, and neonatal diseases and abnormalities ,medicine.medical_specialty ,Visual acuity ,business.industry ,Hearing loss ,Nephritis, Hereditary ,General Medicine ,urologic and male genital diseases ,medicine.disease ,female genital diseases and pregnancy complications ,Anterior lenticonus ,Lens Diseases ,Ophthalmology ,otorhinolaryngologic diseases ,medicine ,Sensorineural hearing loss ,medicine.symptom ,Family history ,Alport syndrome ,business ,Kidney disease ,Retinopathy - Abstract
Alport syndrome is an inherited progressive form of glomerular disease that is often associated with sensorineural hearing loss and ocular abnormalities. We report two men with Alport syndrome. Both had chronic kidney disease and consulted for long-term loss of visual acuity. One had auditory abnormalities. On the ophthalmological examination, both had anterior lenticonus and one had dot or fleck retinopathy. Those findings are described in up to 50% and 70% of men with X-linked Alport syndrome, respectively. Both patients had a family history of Alport syndrome or suggestive signs and symptoms.
- Published
- 2019
- Full Text
- View/download PDF
45. Comparing prediction accuracy between total keratometry and conventional keratometry in cataract surgery with refractive multifocal intraocular lens implantation
- Author
-
Youngjun Kim, Jae Yong Kim, Hun Lee, Ho Seok Chung, Jae Lim Chung, and Hungwon Tchah
- Subjects
Adult ,Male ,medicine.medical_specialty ,genetic structures ,medicine.medical_treatment ,Mean squared prediction error ,Science ,Mean absolute error ,Cataract Extraction ,Article ,law.invention ,Cornea ,Postoperative Complications ,Lens Implantation, Intraocular ,law ,Ophthalmology ,medicine ,Humans ,Lens Diseases ,Dioptre ,Aged ,Retrospective Studies ,Multidisciplinary ,Keratometer ,business.industry ,Vision Tests ,Cataract surgery ,Multifocal intraocular lens ,Middle Aged ,Refractive Errors ,Multifocal Intraocular Lenses ,eye diseases ,Treatment Outcome ,Optical biometer ,Medicine ,Lens diseases ,Female ,sense organs ,business ,Tomography, Optical Coherence - Abstract
We aimed to compare refractive outcomes between total keratometry using a swept-source optical biometer and conventional keratometry in cataract surgery with refractive multifocal intraocular lens (IOL) implantation. We included patients who underwent cataract surgery with refractive multifocal IOL implantation. The IOL power was calculated using conventional formulas (Haigis, SRK/T, Holladay 2, and Barrett Universal II) as well as a new formula (Barrett TK Universal II). The refractive mean error, mean absolute error, and median absolute error were compared, as were the proportions of eyes within ± 0.25 diopters (D), ± 0.50 D, and ± 1.00 D of prediction error. In total 543 eyes of 543 patients, the absolute prediction error of total keratometry was significantly higher than that of conventional keratometry using the SRK/T (P = 0.034) and Barrett Universal II (P = 0.003). The proportion of eyes within ± 0.50 D of the prediction error using the SRK/T and Barrett Universal II was also significantly higher when using conventional keratometry than total keratometry (P = 0.010 for SRK/T and P = 0.005 for Barrett Universal II). Prediction accuracy of conventional keratometry was higher than that of total keratometry in cataract surgery with refractive multifocal IOL implantation.
- Published
- 2021
46. Influence of frosted haptics on rotational stability of toric intraocular lenses
- Author
-
Masaharu Iida, Ruriko Takaku, Tetsuro Oshika, and Shinichiro Nakano
- Subjects
Male ,medicine.medical_specialty ,Science ,medicine.medical_treatment ,Visual Acuity ,Statistical difference ,Intraocular lens ,Astigmatism ,Refraction, Ocular ,Article ,Clinical study ,03 medical and health sciences ,0302 clinical medicine ,Lens Implantation, Intraocular ,Ophthalmology ,medicine ,Humans ,Eye diseases ,Aged ,Retrospective Studies ,Mathematics ,Lenses, Intraocular ,Phacoemulsification ,Multidisciplinary ,medicine.disease ,Intraocular lenses ,Capsular bag ,030221 ophthalmology & optometry ,Medicine ,Lens diseases ,Female ,Rotational stability ,030217 neurology & neurosurgery - Abstract
We investigated the unfolding property and rotational stability of a new toric intraocular lens (IOL); TECNIS toric II (toric-II, ZCW, Johnson & Johnson) that is an improved version of TECNIS toric IOL (toric-I, ZCV). Both IOLs are based on an identical platform, except for the frosted haptics with toric-II IOL. The study consisted of two parts; experimental study and clinical, retrospective, case series. Experimental study indicated that the overall time from IOL ejection to unfolding to 11 mm was significantly shorter with toricII than toric-I IOLs (p = 0.032), due to the earlier separation of the haptics from the optic with toric-II IOL. Clinical study included 131 eyes of 99 patients who had undergone phacoemulsification and toric IOL implantation. At 3 months postoperatively, toric-II IOL showed significantly better rotational stability than toric-I IOL, including smaller residual manifest astigmatism (p = 0.018), less amount of axis misalignment from the intended axis (p = 0.04), lower incidence of misalignment > 10º (p = 0.0044), and less degree of prediction errors (p = 0.043). Postoperative uncorrected distance visual acuity tended to be better in the toric-II than in the toric-I groups, with marginal statistical difference (p = 0.057). TECNIS toric II IOL with the frosted haptics showed significantly better rotational stability than its predecessor, probably due to quicker unfolding and greater friction with the capsular bag.
- Published
- 2021
- Full Text
- View/download PDF
47. Persistent anterior tunica vasculosa lentis in multisystemic smooth muscle dysfunction syndrome
- Author
-
She, Kaiqin, Liang, Licong, and Lu, Fang
- Subjects
congenital mydriasis ,persistent anterior tunica vascluosa lentis ,Infant, Newborn ,Muscle, Smooth ,retinal arteriolar tortuosity ,Lens Diseases ,Muscular Diseases ,Retinal Diseases ,Lens, Crystalline ,case report ,Humans ,Female ,Clinical Case Report ,Research Article ,multisystemic smooth muscle dysfunction syndrome - Abstract
Rationale: Multisystemic smooth muscle dysfunction syndrome (MSMDS) is a genetic disease that affects multiple organs. The report here concerns a patient with MSMDS, who is known so far as the youngest among all the reported patients. In addition to the typical manifestations, we observed previously unreported ocular abnormalities, including persistent anterior tunica vasculosa lentis (TVL) and early-onset retinal arteriolar tortuosity, by the fluorescein angiography (FA). Patient concerns: The patient was admitted to the neonatal intensive care unit immediately after birth for a diagnosis of urinary system dysplasia during fetal life. After a thorough examination, the patient was found with patent ductus arteriosus, pulmonary hypertension, cerebrovascular disease, hypotonic bladder, intestinal malrotation, and congenital mydriasis. The FA of the eyes undertaken in her 6-week demonstrated perfused vasculature in the persistent anterior TVL and prominent retinal arteriolar tortuosity. The whole exome sequencing revealed a de novo heterozygous ACTA2 gene missense mutation p.R179H. Diagnoses: The patient was diagnosed with MSMDS. Interventions: Follow-up observation. Outcomes: At the 3-month follow-up, no change of the ocular disease was observed. Lessons: The persistent anterior TVL in this case implies that ACTA2 p.R179H mutation affects not only the smooth muscle cells but also the pericytes, and further affects the TVL regression. The prominent retinal arteriolar tortuosity in this 6-week-old infant indicates that the retinal arteriolar tortuosity can present early in MSMDS.
- Published
- 2021
48. Long term outcome of combined phacoemulsification and excisional goniotomy with the Kahook Dual Blade in different subtypes of glaucoma
- Author
-
Ahmed Al Habash and Abdulrahman Albuainain
- Subjects
Male ,030213 general clinical medicine ,medicine.medical_specialty ,Intraocular pressure ,Time Factors ,genetic structures ,Science ,medicine.medical_treatment ,Visual rehabilitation ,Visual Acuity ,Glaucoma ,Trabeculectomy ,Diseases ,Article ,03 medical and health sciences ,Medical research ,0302 clinical medicine ,Pseudoexfoliation glaucoma ,Ophthalmology ,Humans ,Medicine ,In patient ,Lens Diseases ,Eye diseases ,Aged ,Phacoemulsification ,Multidisciplinary ,business.industry ,Disease Management ,Combined procedure ,Middle Aged ,Prognosis ,medicine.disease ,Combined Modality Therapy ,eye diseases ,Treatment Outcome ,Outcomes research ,030221 ophthalmology & optometry ,Female ,Lens diseases ,sense organs ,business - Abstract
Purpose: To characterize changes in intraocular pressure (IOP), IOP-lowering medications, and visual acuity (VA) through 3 years of follow-up in patients undergoing combined phacoemulsification and excisional goniotomy with the Kahook Dual Blade (phaco-KDB), with simultaneous goniosynechialysis in cases of angle-closure glaucoma, by a single surgeon (A.H.) in King Fahd Hospital of the University, Dammam, Saudi Arabia.Methods: Prospective, non-comparative, uncontrolled, non-randomized interventional case series. Consecutive patients with medically-treated glaucoma and visually-significant cataract underwent combined surgery. Subgroup analysis of glaucoma subtypes was performed.Results: Fifty-seven eyes (48 patients) including 29 eyes with primary open-angle glaucoma, 15 with pseudoexfoliation glaucoma, and 13 with angle-closure glaucoma, were enrolled. Mean (standard error) baseline IOP was 20.3 (0.7) mmHg and through up to 36 months of follow-up (minimum 12 months, mean 26.2 [1.0] months) ranged from 13.5-14.0 mmHg (13.7 mmHg at Month 36); significant reductions (p<0.0002) of 23.6-29.9% were achieved at every time point. Medications were reduced from a mean of 3.3 (0.1) to 0.2-1.9 (reduction 51.4-94.7%; pConclusions: Phaco-KDB significantly improved VA, lowered IOP ~25-30%, and lowered medications by >50% through 36 months. This combined procedure provides meaningful long-term reductions in IOP and need for IOP-lowering medication without compromising visual rehabilitation in eyes with cataract and glaucoma.
- Published
- 2021
- Full Text
- View/download PDF
49. The kebab technique uses a bipolar pencil to retrieve a dropped nucleus of the lens via a small incision
- Author
-
Harumasa Yokota, Satoru Yamagami, Taiji Nagaoka, Hirotsugu Hanazaki, and Hiroshi Aso
- Subjects
Male ,Intraocular pressure ,medicine.medical_specialty ,Visual acuity ,genetic structures ,Science ,medicine.medical_treatment ,Vitrectomy ,Ophthalmologic Surgical Procedures ,Article ,03 medical and health sciences ,0302 clinical medicine ,Ophthalmology ,Lens, Crystalline ,medicine ,Humans ,Aged ,Aged, 80 and over ,Postoperative Care ,Retina ,Multidisciplinary ,business.industry ,Phacoemulsification ,eye diseases ,Pencil (optics) ,medicine.anatomical_structure ,Vision disorders ,Small incision ,Lens (anatomy) ,030221 ophthalmology & optometry ,Medicine ,Female ,Lens diseases ,sense organs ,medicine.symptom ,business ,030217 neurology & neurosurgery - Abstract
We developed a new method to retrieve a dropped nucleus of the lens via a small incision using bipolar pencils, the kebab technique, to solve the lack of small-gauge fragmatomes, and the expense and toxicity of perfluorocarbon liquids (PFCL). A total of 8 eyes in 6 patients underwent this technique and were reviewed. After vitrectomy, the dropped nucleus of the lens was lifted from the retina by adhesion with a bipolar pencil, and phacoemulsification was performed while rotating the lens. The outcome measures were best-corrected visual acuity (BCVA), intraocular pressure (IOP), and corneal endothelial cell density before and after surgery. Surgical indications included zonular weakness, trauma, acute angle closure attack, and phacolytic glaucoma. At 1 month, BCVA improved from a mean (standard deviation, SD) 1.67 logMAR (0.90) to 1.14 logMAR (1.01). The mean preoperative IOP was 24.5 (16.8) mmHg and postoperative IOP was 11.0 (2.8) mmHg. The mean preoperative corneal endothelial cell count was 2600 (322) cells/mm2 (one eye was unmeasurable) and postoperative corneal endothelial cell count was 2387 (431) cells/mm2. There were no postoperative complications. The retrieval of a dropped nucleus of the lens using a bipolar pencil enables small incisions without using PFCL.
- Published
- 2021
- Full Text
- View/download PDF
50. Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length
- Author
-
Hyunggoo Kwon, Ayoung Choi, and Sohee Jeon
- Subjects
medicine.medical_specialty ,genetic structures ,Science ,medicine.medical_treatment ,Mean absolute error ,Intraocular lens ,Astigmatism ,Article ,03 medical and health sciences ,0302 clinical medicine ,Ophthalmology ,Medicine ,Multidisciplinary ,business.industry ,Axial length ,medicine.disease ,eye diseases ,Large cohort ,Alcon Laboratories ,Refractive errors ,030221 ophthalmology & optometry ,Lens diseases ,business ,030217 neurology & neurosurgery - Abstract
The accuracy of intraocular lens (IOL) calculations is suboptimal for long or short eyes, which results in a low visual quality after multifocal IOL implantation. The purpose of the present study is to evaluate the accuracy of IOL formulas (Barrett Universal II, SRK/T, Holladay 1, Hoffer Q, and Haigis) for the Acrysof IQ Panoptix TFNT IOL (Alcon Laboratories, Inc, Fort Worth, Texas, United States) implantation based on the axial length (AXL) from a large cohort of 2018 cases and identify the factors that are associated with a high mean absolute error (MAE). The Barrett Universal II showed the lowest MAE in the normal AXL group (0.30 ± 0.23), whereas the Holladay 1 and Hoffer Q showed the lowest MAE in the short AXL group (0.32 ± 0.22 D and 0.32 ± 0.21 D, respectively). The Haigis showed the lowest MAE in the long AXL group (0.24 ± 0.19 D). The Barrett Universal II did not perform well in short AXL eyes with higher astigmatism (P = 0.013), wider white-to-white (WTW; P P = 0.016). Study results suggest that the Barrett Universal II performed best for the TFNT IOL in the overall study population, except for the eyes with short AXL, particularly when the eyes had higher astigmatism, wider WTW, and shorter AXL.
- Published
- 2021
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.