1. Outcomes of novel 3D-printed fully porous titanium cup and a cemented highly cross-linked polyethylene liner in complex and revision total hip arthroplasty
- Author
-
Ittai Shichman, Lyndsay Somerville, William B. Lutes, Stephen A. Jones, Richard McCalden, and Ran Schwarzkopf
- Subjects
Complex primary THA ,Revision THA ,Bone loss ,Paprosky ,Aseptic loosening ,Orthopedic surgery ,RD701-811 - Abstract
Abstract Introduction A novel fully porous acetabular titanium shell has been designed to reduce stiffness mismatch between bone and implant and promote osseointegration in complex (cTHA) and revision total hip arthroplasty (rTHA). A highly cross-linked polyethylene (XLPE) liner is cemented within the cup to reduce wear rates and increase survivorship. This study reported the outcomes of an XLPE liner cemented into a novel 3D-printed fully porous cup in cTHA and rTHA. Methods Presented was a multicenter retrospective review of 40 patients (6 cTHA and 34 rTHA) who underwent THA with a fully porous titanium acetabular cup and cemented XLPE liner. Data were collected on demographics, surgical information, outcomes, including osseointegration and migration and implant survivorship. Results On average, patients were 71.42 ± 9.97 years old and obese (BMI: 30.36 ± 6.88 kg/m2) and were followed up for a mean time of 2.21 ± 0.77 years. Six patients underwent cTHA and 34 patients underwent rTHA. The mean hospital length of stay was 5.34 ± 3.34 days. Three (7.5%) 90-day readmissions were noted. Harris Hip Scores improved, on average, from 53.87 ± 12.58 preoperatively to 83.53 ± 12.15 postoperatively (P
- Published
- 2022
- Full Text