6 results on '"Youde Ding"'
Search Results
2. PI-YOLO: dynamic sparse attention and lightweight convolutional based YOLO for vessel detection in pathological images
- Author
-
Cong Li, Shuanlong Che, Haotian Gong, Youde Ding, Yizhou Luo, Jianing Xi, Ling Qi, and Guiying Zhang
- Subjects
pathological images ,blood vessel ,deep learning ,object detection ,attention mechanism ,Neoplasms. Tumors. Oncology. Including cancer and carcinogens ,RC254-282 - Abstract
Vessel density within tumor tissues strongly correlates with tumor proliferation and serves as a critical marker for tumor grading. Recognition of vessel density by pathologists is subject to a strong inter-rater bias, thus limiting its prognostic value. There are many challenges in the task of object detection in pathological images, including complex image backgrounds, dense distribution of small targets, and insignificant differences between the features of the target to be detected and the image background. To address these problems and thus help physicians quantify blood vessels in pathology images, we propose Pathological Images-YOLO (PI-YOLO), an enhanced detection network based on YOLOv7. PI-YOLO incorporates the BiFormer attention mechanism, enhancing global feature extraction and accelerating processing for regions with subtle differences. Additionally, it introduces the CARAFE upsampling module, which optimizes feature utilization and information retention for small targets. Furthermore, the GSConv module improves the ELAN module, reducing model parameters and enhancing inference speed while preserving detection accuracy. Experimental results show that our proposed PI-YOLO network has higher detection accuracy compared to Faster-RCNN, SSD, RetinaNet, YOLOv5 network, and the latest YOLOv7 network, with a mAP value of 87.48%, which is 2.83% higher than the original model. We also validated the performance of this network on the ICPR 2012 mitotic dataset with an F1 value of 0.8678, outperforming other methods, demonstrating the advantages of our network in the task of target detection in complex pathology images.
- Published
- 2024
- Full Text
- View/download PDF
3. Enhancing genomic mutation data storage optimization based on the compression of asymmetry of sparsity
- Author
-
Youde Ding, Yuan Liao, Ji He, Jianfeng Ma, Xu Wei, Xuemei Liu, Guiying Zhang, and Jing Wang
- Subjects
genomic ,sparse ,compression ,single-nucleotide variation ,copy number variation ,Genetics ,QH426-470 - Abstract
Background: With the rapid development of high-throughput sequencing technology and the explosive growth of genomic data, storing, transmitting and processing massive amounts of data has become a new challenge. How to achieve fast lossless compression and decompression according to the characteristics of the data to speed up data transmission and processing requires research on relevant compression algorithms.Methods: In this paper, a compression algorithm for sparse asymmetric gene mutations (CA_SAGM) based on the characteristics of sparse genomic mutation data was proposed. The data was first sorted on a row-first basis so that neighboring non-zero elements were as close as possible to each other. The data were then renumbered using the reverse Cuthill-Mckee sorting technique. Finally the data were compressed into sparse row format (CSR) and stored. We had analyzed and compared the results of the CA_SAGM, coordinate format (COO) and compressed sparse column format (CSC) algorithms for sparse asymmetric genomic data. Nine types of single-nucleotide variation (SNV) data and six types of copy number variation (CNV) data from the TCGA database were used as the subjects of this study. Compression and decompression time, compression and decompression rate, compression memory and compression ratio were used as evaluation metrics. The correlation between each metric and the basic characteristics of the original data was further investigated.Results: The experimental results showed that the COO method had the shortest compression time, the fastest compression rate and the largest compression ratio, and had the best compression performance. CSC compression performance was the worst, and CA_SAGM compression performance was between the two. When decompressing the data, CA_SAGM performed the best, with the shortest decompression time and the fastest decompression rate. COO decompression performance was the worst. With increasing sparsity, the COO, CSC and CA_SAGM algorithms all exhibited longer compression and decompression times, lower compression and decompression rates, larger compression memory and lower compression ratios. When the sparsity was large, the compression memory and compression ratio of the three algorithms showed no difference characteristics, but the rest of the indexes were still different.Conclusion: CA_SAGM was an efficient compression algorithm that combines compression and decompression performance for sparse genomic mutation data.
- Published
- 2023
- Full Text
- View/download PDF
4. Adaptive Recursive Least Squares Denoising in Ventricular Fibrillation ECG Signals
- Author
-
Youde Ding, Yuan Liao, Yongqin Li, Jing Wang, Ji He, Guoxi Xie, and Guiying Zhang
- Subjects
adaptive recursive least squares ,cardiac arrest ,electrocardiograms ,ventricular fibrillation ,Technology (General) ,T1-995 ,Science - Abstract
Abstract Cardiac arrest is a fatal and urgent disease in humans. A high‐quality electrocardiogram (ECG) has a positive guide to the success of defibrillation and resuscitation. However, because of artificial motion interference and ambient noise, reliable ECG signals can be obtained only during chest compression (CC) pauses. To address this issue, the adaptive recursive least squares (RLS) denoising approach is proposed. First, the ECG signals of porcine are divided into three groups: CC, without CC, and both with and without CC. Then, five Gaussian noises with different signals‐to‐noise ratios (SNR) and five noises with different distribution types are added, respectively. Furthermore, RLS is compared with six other different denoising approaches. Experimental results demonstrate significant differences between RLS and the other six algorithms in main metrics. SNR and related factors are larger, while the root mean square error is smaller. In conclusion, RLS can significantly eliminate many types of ambient noise, and improve the quality of ECG signals during cardiopulmonary resuscitation.
- Published
- 2023
- Full Text
- View/download PDF
5. Estimating the amplitude spectrum area of ventricular fibrillation during cardiopulmonary resuscitation using only ECG waveform
- Author
-
Yongqin Li, Yiming Shen, Liang Wei, Youde Ding, Yushun Gong, Feng Zuo, Chenxi Dai, and Juan Wang
- Subjects
medicine.medical_specialty ,Receiver operating characteristic ,Defibrillation ,business.industry ,medicine.medical_treatment ,030208 emergency & critical care medicine ,General Medicine ,030204 cardiovascular system & hematology ,medicine.disease ,Frequency spectrum ,03 medical and health sciences ,0302 clinical medicine ,Signal quality ,Internal medicine ,Artifact suppression ,Ventricular fibrillation ,medicine ,Cardiology ,Waveform ,Original Article ,Cardiopulmonary resuscitation ,business - Abstract
BACKGROUND: Amplitude spectrum area (AMSA) calculated from ventricular fibrillation (VF) can be used to monitor the effectiveness of chest compression (CC) and optimize the timing of defibrillation. However, reliable AMSA can only be obtained during CC pause because of artifacts. In this study, we sought to develop a method for estimating AMSA during cardiopulmonary resuscitation (CPR) using only the electrocardiogram (ECG) waveform. METHODS: Intervals of 8 seconds ECG and CC-related references, including 4 seconds during CC and an adjacent 4 seconds without CC, were collected before 1,008 defibrillation shocks from 512 out-of-hospital cardiac arrest patients. Signal quality was analyzed based on the irregularity of autocorrelation of VF. If signal quality index (SQI) was high, AMSA would be calculated from the original signal. Otherwise, CC-related artifacts would be constructed and suppressed using the least mean square filter from VF before calculation of AMSA. The algorithm was optimized using 480 training shocks and evaluated using 528 independent testing shocks. RESULTS: Overall, CC resulted in lower SQI [0.15 (0.04–0.61) with CC vs. 0.75 (0.61–0.83) without CC, P
- Published
- 2021
6. Short Duration Combined Mild Hypothermia Improves Resuscitation Outcomes in a Porcine Model of Prolonged Cardiac Arrest
- Author
-
Yongqin Li, Youde Ding, Zitong Huang, Tao Yu, Zhengfei Yang, and Heng Li
- Subjects
Male ,Resuscitation ,Mild hypothermia ,Cardiac output ,Time Factors ,Article Subject ,Swine ,medicine.medical_treatment ,lcsh:Medicine ,Apoptosis ,General Biochemistry, Genetics and Molecular Biology ,Hypothermia, Induced ,medicine ,Hippocampus (mythology) ,Animals ,Cardiopulmonary resuscitation ,Short duration ,General Immunology and Microbiology ,business.industry ,lcsh:R ,General Medicine ,Hypothermia ,medicine.disease ,Cardiopulmonary Resuscitation ,Heart Arrest ,Disease Models, Animal ,Treatment Outcome ,Anesthesia ,Ventricular fibrillation ,medicine.symptom ,business ,Research Article - Abstract
Objective.In this study, our aim was to investigate the effects of combined hypothermia with short duration maintenance on the resuscitation outcomes in a porcine model of ventricular fibrillation (VF).Methods.Fourteen porcine models were electrically induced with VF and untreated for 11 mins. All animals were successfully resuscitated manually and then randomized into two groups: combined mild hypothermia (CH group) and normothermia group (NT group). A combined hypothermia of ice cold saline infusion and surface cooling was implemented in the animals of the CH group and maintained for 4 hours. The survival outcomes and neurological function were evaluated every 24 hours until a maximum of 96 hours. Neuron apoptosis in hippocampus was analyzed.Results.There were no significant differences in baseline physiologies and primary resuscitation outcomes between both groups. Obvious improvements of cardiac output were observed in the CH group at 120, 180, and 240 mins following resuscitation. The animals demonstrated better survival at 96 hours in the CH group when compared to the NT group. In comparison with the NT group, favorable neurological functions were observed in the CH group.Conclusion.Short duration combined cooling initiated after resuscitation improves survival and neurological outcomes in a porcine model of prolonged VF.
- Published
- 2015
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.