1. Utility evaluation of HLA-B*13:01 screening in preventing trichloroethylene-induced hypersensitivity syndrome in a prospective cohort study
- Author
-
Yong Niu, Haiyan Dong, Yingping Xiang, Wei Zhou, Yan Sha, Yuxin Zheng, Ping Bin, Jiaxi He, Meili Shen, Juan Yi, Qiang Jia, Yufei Dai, Huiping Huang, Xianqing Huang, Meng Ye, and Huawei Duan
- Subjects
medicine.medical_specialty ,business.industry ,Incidence (epidemiology) ,Public Health, Environmental and Occupational Health ,Cost-effectiveness analysis ,Disease ,030207 dermatology & venereal diseases ,03 medical and health sciences ,0302 clinical medicine ,Internal medicine ,Relative risk ,Positive predicative value ,medicine ,Genetic predisposition ,business ,Adverse effect ,Prospective cohort study ,030217 neurology & neurosurgery - Abstract
ObjectivesTrichloroethylene (TCE) -induced hypersensitivity syndrome (TIHS) is a potentially life-threatening disease. Several genetic susceptibility biomarkers have been found to be associated with TIHS, and this systematic prospective study has been conducted to evaluate the utility of these genetic susceptibility biomarkers in preventing the disease.MethodsThe newly hired TCE-exposed workers were recruited from March 2009 to October 2010. HLA-B*13:01 genotyping and 3-month follow-up procedure were conducted. All workers were monitored for adverse reaction by telephone interview every week. The workers with early symptoms of TIHS were asked to go to the hospital immediately for further examination, diagnosis and treatment. The medical expense record data of patients with TIHS were collected for cost-effectiveness analysis in 2018.ResultsAmong 1651 workers, 158 (9.57%) were found to carry the HLA-B*13:01 allele and 16 (0.97%) were diagnosed with TIHS. HLA-B*13:01 allele was significantly associated with an increased TIHS risk (relative risk=28.4, 95% CI 9.2 to 86.8). As a risk predictor of TIHS, HLA-B*13:01 testing had a sensitivity of 75%, a specificity of 91.1% and an area under curve of 0.83 (95% CI 0.705 to 0.955), the positive and negative predictive values were 7.6% and 99.7%, respectively. The incidence of TIHS was significantly decreased in HLA-B*13:01 non-carriers (0.27%) compared with all workers (0.97%, p=0.014). Cost-effectiveness analysis showed that HLA-B*13:01 screening could produce an economic saving of $4604 per TIHS avoided.ConclusionsProspective HLA-B*13:01 screening may significantly reduce the incidence of TIHS and could be a cost effective option for preventing the disease in TCE-exposed workers.
- Published
- 2020
- Full Text
- View/download PDF