1. Symmetric curvature patterns for colonic polyp detection.
- Author
-
Jerebko A, Lakare S, Cathier P, Periaswamy S, and Bogoni L
- Subjects
- Humans, Radiographic Image Enhancement methods, Reproducibility of Results, Sensitivity and Specificity, Algorithms, Artificial Intelligence, Colonic Polyps diagnostic imaging, Colonography, Computed Tomographic methods, Pattern Recognition, Automated methods, Radiographic Image Interpretation, Computer-Assisted methods
- Abstract
A novel approach for generating a set of features derived from properties of patterns of curvature is introduced as a part of a computer aided colonic polyp detection system. The resulting sensitivity was 84% with 4.8 false positives per volume on an independent test set of 72 patients (56 polyps). When used in conjunction with other features, it allowed the detection system to reach an overall sensitivity of 94% with a false positive rate of 4.3 per volume.
- Published
- 2006