1. The effect of serum pretreatment regimens for the detection of HLA class I antibodies in platelet-refractory patients
- Author
-
Nalaja Marcus, Susan Hsu, Thomas J. Gniadek, Manish J. Gandhi, Mark K. Fung, Birgit S. Gathof, Minoko Takanashi, Ellen Klohe, Roberta Bamert, Gizem Tumer, Ryan Pena, Heather Dunckley, Jennifer Baye, Shona Sims, Lynette Beaudin, Silvano Wendel, Claudia S. Cohn, and Paul Warner
- Subjects
Blood Platelets ,Male ,medicine.medical_specialty ,Coefficient of variation ,Immunology ,Human leukocyte antigen ,030204 cardiovascular system & hematology ,Gastroenterology ,03 medical and health sciences ,0302 clinical medicine ,Refractory ,Antibody Specificity ,HLA Antigens ,Isoantibodies ,Internal medicine ,Immunology and Allergy ,Medicine ,Humans ,Platelet ,Single antigen bead ,Edetic Acid ,biology ,business.industry ,Histocompatibility Testing ,Histocompatibility Antigens Class I ,Hematology ,Confidence interval ,Dithiothreitol ,Immunoglobulin M ,biology.protein ,Female ,Antibody ,business ,030215 immunology - Abstract
BACKGROUND Single antigen bead (SAB) assays are used to identify human leukocyte antigen (HLA) antibodies in patients with platelet refractoriness due to HLA Class I alloimmunization. Some laboratories use serum pretreatment regimens to eliminate interference from immunoglobulin M antibodies and complement. These modifications may contribute to interlaboratory variability, which is a recognized problem with the SAB assay. STUDY DESIGN AND METHODS Five patients & apos; sera were overnight shipped to 12 laboratories in the United States and internationally. Recipients used their lab & apos;s SAB procedure to identify HLA Class I antibodies. The resultant mean fluorescence intensity (MFI) data were compared by instrumentation, bead lot, and pretreatment regimens. Laboratory-specific cutoffs for positive antibodies were applied to the results. RESULTS Interlaboratory variability for MFI values appears to be associated with different pretreatment regimens. The coefficient of variation (CV) of MFI from samples pretreated with ethylenediaminetetraacetic acid, dithiothreitol, or heat inactivation (EDHI) were similar, ranging from 14% to 56% (mean, 22%). For samples with no pretreatment, the CVs were significantly higher than EDHI-treated samples, ranging from 25% to 74% (mean, 39%; 95% confidence interval, 12.10-21.90; p < 0.0001). An intralaboratory comparison of pretreatment regimens confirmed these findings. Some positive antibody specificities present in EDHI-treated samples were negative in corresponding samples with no pretreatment when laboratory-specific cutoffs for positive antibodies were applied. CONCLUSION Our results show that greater interlaboratory precision can be achieved when samples are pretreated with EDHI as opposed to no pretreatment, likely because these pretreatments eliminate interference from inhibitors. Inhibitors may mask antibodies, leading to missed (or uncalled) specificities when no pretreatment is used.
- Published
- 2019