1. A revisited hemolytic assay for palytoxin detection: Limitations for its quantitation in mussels
- Author
-
Marco Pelin, Silvio Sosa, Aurelia Tubaro, Mark A. Poli, Valentina Brovedani, Katia Varello, Martino Forino, Brovedani, Valentina, Sosa, Silvio, Poli, M., Forino, M., Varello, K., Tubaro, Aurelia, Pelin, Marco, Poli, Mark, Forino, Martino, and Varello, Katia
- Subjects
Erythrocytes ,Cross Reactions ,010501 environmental sciences ,Toxicology ,Hemolysis ,01 natural sciences ,chemistry.chemical_compound ,Cnidarian Venoms ,Limit of Detection ,Palytoxin ,Animals ,Humans ,hemolytic assay ,matrix effect ,Mytilus galloprovincialis ,Shellfish ,0105 earth and related environmental sciences ,Detection limit ,Acrylamides ,Chromatography ,Complex matrix ,biology ,Palytoxin Hemolytic assay Matrix effect Mytilus galloprovincialis ,010401 analytical chemistry ,Phosphate buffered saline ,Reproducibility of Results ,Repeatability ,biology.organism_classification ,Mytilus ,Bivalvia ,0104 chemical sciences ,chemistry ,Environmental chemistry ,Human erythrocytes - Abstract
Palytoxin (PLTX) and its analogues have been detected as seafood contaminants associated with a series of human foodborne poisonings. Due to a number of fatalities ascribed to the ingestion of PLTX-contaminated marine organisms, the development of methods for its detection in seafood has been recommended by the European Food Safety Authority (EFSA). Due to its feasibility, the spectrophotometric hemolytic assay is widely used to detect PLTX in different matrices, even though a standardized protocol is still lacking. Thus, on the basis of available assay procedures, a new standardized protocol was set up using purified human erythrocytes exposed to PLTX (working range: 3.9 × 10(-10)-2.5 × 10(-8) M) in a K(+)-free phosphate buffered saline solution, employing a 5 h incubation at 41 °C. An intra-laboratory characterization demonstrated its sensitivity (limit of detection, LOD = 1.4 × 10(-10) M and quantitation, LOQ = 3.4 × 10(-10) M), accuracy (bias = -0.8%), repeatability (RSDr = 15% and 6% for intra- and inter-day repeatability, respectively) and specificity. However, the standardized method seems not to be suitable for PLTX quantitation in complex matrices, such as mussel (Mytilus galloprovincialis) extracts, at least below the limit suggested by EFSA (30 μg PLTXs/Kg shellfish meat). Thus, the hemolytic assay for PLTX quantitation in seafood should be used only after a careful evaluation of the specific matrix effects.
- Published
- 2016
- Full Text
- View/download PDF