1. Two dimensional echocardiographic assessment of patients with bioprosthetic valves.
- Author
-
Schapira JN, Martin RP, Fowles RE, Rakowski H, Stinson EB, French JW, Shumway NE, and Popp RL
- Subjects
- Adolescent, Adult, Aged, Cardiac Catheterization, Child, Coronary Angiography, Endocarditis, Bacterial complications, Endocarditis, Bacterial diagnosis, Female, Heart Diseases complications, Heart Diseases diagnosis, Humans, Male, Middle Aged, Aortic Valve surgery, Bioprosthesis, Echocardiography methods, Heart Valve Prosthesis, Mitral Valve surgery, Tricuspid Valve surgery
- Abstract
The clinical utility of two dimensional echocardiography in assessing bioprosthetic and left ventricular function was studied in 40 consecutive patients 1 week to 60 months after valve replacement surgery. These patients were referred to obtain normal baseline studies as well as to evaluate complications:suspected endocarditis, embolic phenomena and congestive heart failure of unknown cause. Independent M mode echocardiograms were also obtained in each patient. Confirmation of ultrasonic studies was by cardiac catheterization with angiography, surgery and pathologic study in 10 patients; cardiac catheterization with angiography alone in 7 patients; surgery and pathologic study in 3 patients; autopsy in 3 patients; blood cultures to confirm or exclude endocarditis in 10 patients; and confirmation on clinical grounds in 7 patients. Technically adequate two dimensional studies were recorded in 39 of 40 subjects. Two dimensional echocardiography accurately assessed 15 of 16 patients with an abnormal bioprosthetic valve and a normal left ventricle (1 of 16 patients had a false positive two dimensional echocardiogram); 8 of 8 patients suspected to have prosthetic valve or left ventricular dysfunction but who were normal; 7 of 7 patients with a normal prosthesis and an abnormal left ventricle; the one patient with an abnormal valve and left ventricle; and 7 of 7 clinically normal patients who were referred for baseline studies. In summary, the two-dimensional echocardiogram demonstrated a 97 percent diagnostic accuracy rate which was significantly greater than the 67 percent (P less than 0.001) for M mode echocardiography in the same group of patients. It is concluded that two dimensional echocardiography has excellent diagnostic accuracy in assessing bioprosthetic and left ventricular function and is superior to M mode echocardiography in evaluating patients after such valve replacement.
- Published
- 1979
- Full Text
- View/download PDF