1. Expert-Based Narrative Review on Contemporary Use of an Off-The-Shelf Multibranched Endograft for Endovascular Treatment of Thoracoabdominal Aortic Aneurysms: Device Design, Anatomical Suitability, Technical Tips, Perioperative Care, Clinical Applications, and Real-World Experience.
- Author
-
Chen Y, Bashir M, Guo J, Piffaretti G, Jubouri M, and D'Oria M
- Subjects
- Humans, Treatment Outcome, Risk Factors, Postoperative Complications etiology, Male, Female, Aortic Aneurysm, Thoracoabdominal, Blood Vessel Prosthesis, Endovascular Procedures instrumentation, Endovascular Procedures adverse effects, Prosthesis Design, Aortic Aneurysm, Thoracic surgery, Aortic Aneurysm, Thoracic diagnostic imaging, Blood Vessel Prosthesis Implantation instrumentation, Blood Vessel Prosthesis Implantation adverse effects, Stents
- Abstract
Advanced endovascular techniques, such as fenestrated stent grafts, are nowadays available that permit minimally invasive treatment of complex abdominal aortic aneurysms. However, thoracoabdominal aortic aneurysm patients have anatomic limitations to fenestrated stent-grafts given a large lumen, that is, the gap between the endograft and the inner aortic wall. This has led to the development of branched endovascular aneurysm repair as the ideal option for such patients. The Zenith t-Branch multibranched endograft (Cook Medical, Bloomington, IN), which has been commercially available in Europe to treat thoracoabdominal aortic aneurysm since June 2012, represents a feasible off-the-shelf alternative for treatment of such pathologies, especially in the urgent setting, for patients who cannot wait the time required for manufacturing and delivery of custom-made endografts. The device's anatomical suitability should be considered, especially for female patients with smaller iliofemoral vessels. Several tips may help deal with particularly complex scenarios (such as, for instance, in case of narrow inner aortic lumens or when treating patients with failure of prior endovascular aneurysm repair), and a broad array of techniques and devices must be available to ensure technical and clinical success. Despite promising early outcomes, concerns remain particularly regarding the risk for spinal cord ischemia and further assessment of long-term durability is needed, including the rate of target vessel instability and need for secondary interventions. As the published evidence mainly comes from retrospective registries, it is likely that reported outcomes may suffer from an intrinsic bias as most procedures reported to date have been carried out at high-volume aortic centers. Nonetheless, with the never-ceasing adoption of new and refined techniques, outcomes are expected to ameliorate., (Copyright © 2024 The Author(s). Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF