1. Radiofrequency Energy Applications Targeting Significant Residual Leaks After Watchman Implantation
- Author
-
Andrea Natale, Subramaniam C. Krishnan, Dhanunjaya Lakkireddy, Krishna Akella, J. David Burkhardt, Rodney Horton, Rakesh Gopinathannair, Giovanni B. Forleo, Javier Sanchez, Nicola Tarantino, Domenico G. Della Rocca, Ghulam Murtaza, Chintan Trivedi, Armando Del Prete, Amin Al-Ahmad, Jorge Romero, Carola Gianni, Shephal K. Doshi, G. Joseph Gallinghouse, Carlo Lavalle, Michele Magnocavallo, Mohamed Bassiouny, Sanghamitra Mohanty, Luigi Di Biase, Veronica Natale, and Philip J. Patel
- Subjects
Leak ,Percutaneous ,medicine.diagnostic_test ,business.industry ,Atrial fibrillation ,Transesophageal echocardiogram ,medicine.disease ,Left atrial ,Occlusion ,Medicine ,Nuclear medicine ,business ,Stroke ,Radiofrequency energy - Abstract
Objectives The aim of this study was to evaluate the efficacy of radiofrequency (RF) energy applications targeting the atrial side of a significant residual leak in patients with acute and chronic evidence of incomplete percutaneous left atrial appendage (LAA) occlusion. Background RF applications have been proved to prevent recanalization of intracranial aneurysms after coil embolization, thereby favoring complete sealing. From a mechanistic standpoint, in vitro and in vivo experiments have demonstrated that RF promotes collagen deposition and tissue retraction. Methods Forty-three patients (mean age 75 ± 7 years mean CHA2DS2-VASc score 4.6 ± 1.4, mean HAS-BLED score 4.0 ± 1.1) with residual leaks ≥4 mm after Watchman implantation were enrolled. Procedural success was defined as complete LAA occlusion or presence of a mild or minimal (1- to 2-mm) peridevice leak on follow-up transesophageal echocardiography (TEE), which was performed approximately 45 days after the procedure. Results RF-based leak closure was performed acutely after Watchman implantation in 19 patients (44.2%) or scheduled after evidence of significant leaks on follow-up TEE in 24 others (55.8%). The median leak size was 5 mm (range: 4-7 mm). On average, 18 ± 7 RF applications per patient (mean maximum contact force 16 ± 3 g, mean power 44 ± 2 W, mean RF time 5.1 ± 2.5 minutes) were performed targeting the atrial edge of the leak. Post-RF median leak size was 0 mm (range: 0-1 mm). A very low rate (2.3% [n = 1]) of major periprocedural complications was observed. Follow-up TEE revealed complete LAA sealing in 23 patients (53.5%) and negligible residual leaks in 15 (34.9%). Conclusions RF applications targeting the atrial edge of a significant peri-Watchman leak may promote LAA sealing via tissue remodeling, without increasing complications. (RF Applications for Residual LAA Leaks [REACT]; NCT04726943 )
- Published
- 2021
- Full Text
- View/download PDF