1. The Cataract National Dataset electronic multi-centre audit of 55,567 operations: updating benchmark standards of care in the United Kingdom and internationally.
- Author
-
Jaycock P, Johnston RL, Taylor H, Adams M, Tole DM, Galloway P, Canning C, and Sparrow JM
- Subjects
- Aged, Anesthesia statistics & numerical data, Cataract Extraction statistics & numerical data, Databases, Factual statistics & numerical data, Female, Humans, Male, Medical Audit, Ophthalmology statistics & numerical data, Preoperative Care, Reference Standards, United Kingdom, Vision Disorders physiopathology, Visual Acuity physiology, Cataract physiopathology, Cataract Extraction standards
- Abstract
Aims: To pilot the use of the Cataract National Dataset (CND) using multi-centre data from Electronic Patient Record (EPR) systems and to demonstrate the ability of the CND to deliver certain of its intended benefits, including detailed preoperative profiling of cataract surgery patients and updating of benchmark standards of care in the NHS and beyond., Methods: NHS departments using EPR systems to collect a minimum preoperative, anaesthetic, operative and postoperative data set, the CND, were invited to submit data, which were remotely extracted, anonymised, assessed for conformity and completeness, and analysed., Results: Four-hundred and six surgeons from 12 NHS Trusts submitted data on 55,567 cataract operations between November 2001 and July 2006 (86% from January 2004). Mean age (SD) was 75.4 (10.4) years, 62.0% female. Surgery was for first eyes in 58.5%, under local anaesthesia in 95.5% and by phacoemulsification in 99.7%. Trainees performed 33.9% of operations. Preoperative visual acuity (VA) was 6/12 or better in 42.9% eyes overall, in 35.3% first eyes and in 55.3% second eyes. Complication rates included the following: posterior capsule rupture and/or vitreous loss of 1.92%, simple zonule dialysis of 0.46% and retained lens fragments of 0.18%. Postoperative VA of 6/12 or better (and 6/6 or better) was achieved for 91.0% (45.9%) of all eyes, 94.7% (51.0%) of eyes with no co-pathologies and 79.9% (30.2%) of eyes with one or more co-pathologies respectively., Conclusions: The CND is fit for purpose, is able to deliver useful benefits and can be collected as part of routine clinical care via EPR systems. This survey confirms shifts in practice since the 1997-1998 UK National Survey with full conversion to phacoemulsification, better preoperative acuity, a halving of the surgical 'index' benchmark complication of posterior capsule rupture and/or vitreous loss, and improved VA outcomes.
- Published
- 2009
- Full Text
- View/download PDF