1. Perioperative mortality after hemiarthroplasty related to fixation method.
- Author
-
Costain, Darren J, Whitehouse, Sarah L, Pratt, Nicole L, Graves, Stephen E, Ryan, Philip, and Crawford, Ross W
- Subjects
- *
BONE surgery , *BONE fractures , *HIP joint injury treatment , *HIP surgery , *ARTIFICIAL joints , *COMPUTER software , *CONFIDENCE intervals , *REPORTING of diseases , *FRACTURE fixation , *ARTIFICIAL implants , *REOPERATION , *SURGICAL complications , *SURVIVAL analysis (Biometry) , *TIME , *TOTAL hip replacement , *DATA analysis , *PROPORTIONAL hazards models - Abstract
Background and purpose The appropriate fixation method for hemiarthroplasty of the hip as it relates to implant survivorship and patient mortality is a matter of ongoing debate. We examined the influence of fixation method on revision rate and mortality. Methods We analyzed approximately 25,000 hemiarthroplasty cases from the AOA National Joint Replacement Registry. Deaths at 1 day, 1 week, 1 month, and 1 year were compared for all patients and among subgroups based on implant type. Results Patients treated with cemented monoblock hemiarthroplasty had a 1.7-times higher day-1 mortality compared to uncemented monoblock components (p < 0.001). This finding was reversed by 1 week, 1 month, and 1 year after surgery (p < 0.001). Modular hemiarthroplasties did not reveal a difference in mortality between fixation methods at any time point. Interpretation This study shows lower (or similar) overall mortality with cemented hemiarthroplasty of the hip. [ABSTRACT FROM AUTHOR]
- Published
- 2011
- Full Text