1. Diaphragmatic mobility in healthy subjects during incentive spirometry with a flow-oriented device and with a volume-oriented device.
- Author
-
Yamaguti WP, Sakamoto ET, Panazzolo D, Peixoto Cda C, Cerri GG, and Albuquerque AL
- Subjects
- Adult, Analysis of Variance, Cross-Over Studies, Diaphragm diagnostic imaging, Female, Humans, Male, Sex Factors, Spirometry instrumentation, Ultrasonography, Young Adult, Breathing Exercises, Diaphragm physiology, Lung physiology
- Abstract
Objective: To compare the diaphragmatic mobility of healthy subjects during incentive spirometry with a volume-oriented device, during incentive spirometry with a flow-oriented device, and during diaphragmatic breathing. To compare men and women in terms of diaphragmatic mobility during these three types of breathing exercises., Methods: We evaluated the pulmonary function and diaphragmatic mobility of 17 adult healthy volunteers (9 women and 8 men). Diaphragmatic mobility was measured via ultrasound during diaphragmatic breathing and during the use of the two types of incentive spirometers., Results: Diaphragmatic mobility was significantly greater during the use of the volume-oriented incentive spirometer than during the use of the flow-oriented incentive spirometer (70.16 ± 12.83 mm vs. 63.66 ± 10.82 mm; p = 0.02). Diaphragmatic breathing led to a greater diaphragmatic mobility than did the use of the flow-oriented incentive spirometer (69.62 ± 11.83 mm vs. 63.66 ± 10.82 mm; p = 0.02). During all three types of breathing exercises, the women showed a higher mobility/FVC ratio than did the men., Conclusions: Incentive spirometry with a volume-oriented device and diaphragmatic breathing promoted greater diaphragmatic mobility than did incentive spirometry with a flow-oriented device. Women performed better on the three types of breathing exercises than did men.
- Published
- 2010
- Full Text
- View/download PDF