1. Early Institutional Experience with One-Piece Bifurcated-Fenestrated Stentgraft in the Treatment of Abdominal Aortic Aneurysms.
- Author
-
Mesnard T, Pruvot L, Oliver Patterson B, Préville A, Azzaoui R, and Sobocinski J
- Subjects
- Humans, Male, Aged, Female, Blood Vessel Prosthesis, Endoleak etiology, Retrospective Studies, Treatment Outcome, Prosthesis Design, Aortic Aneurysm, Abdominal surgery, Blood Vessel Prosthesis Implantation adverse effects, Endovascular Procedures adverse effects
- Abstract
Purpose: To review the early experience of the use of a bifurcated-fenestrated endograft (Bif-FEVAR) to treat abdominal aortic aneurysms (AAA) in a high-volume aortic center., Methods: A retrospective single-center analysis was conducted between March 2019 and April 2021 including consecutive patients that underwent Bif-FEVAR. Only patients without a proper infrarenal neck and a distance <70 mm between the lowest target artery and the native or prosthetic aortic bifurcation were considered. All Bif-FEVAR custom-made devices were manufactured by Cook Medical (Inc., Bloomington, Indiana). Demographics, anatomical features, technical success, major adverse events, 30-day mortality, and survival according to Kaplan-Meier were analyzed according to Society for Vascular Surgery standards., Results: Overall, 10 patients (100% male with median age 78) were included. The median preoperative maximal aneurysm diameter was 68 mm [51-84]. Eight patients were treated for a proximal type I endoleak after endovascular aneurysm repair. A total of 36 fenestrations were planned. The median operative time was 144 min [127-168], with a median fluoro time of 40.5 min [34-54] and a median dose area product of 73 Gy cm
2 [61-89]. Technical success rate was 100%. No patients experienced a major postoperative adverse event. Median follow-up time was 8 months [6-13]., Conclusion: Bif-FEVAR is technically feasible when there is a short distance below the lowest target artery and the aortic bifurcation, with favorable short-term results., Clinical Impact: This study assessed the use of an innovative one-piece bifurcated fenestrated stent-graft as a primary procedure or in the treatment of proximal endoleak after standard infrarenal EVAR. We demonstrated these custom-made devices can be used safely with favorable short-term results. One-piece bifurcated fenestrated stent-grafts extend the indications of FEVAR for patients with an unusually short distance between the lowest renal artery and the aorto-iliac bifurcation or the diverter flow of a preexisting bifurcated infrarenal stent-graft., Competing Interests: Declaration of Conflicting InterestsThe author(s) declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: J.S. is consultant for Cook Medical® and GE Healthcare®.- Published
- 2024
- Full Text
- View/download PDF