1. Individual variation of tentorial notch morphometry in a series of neurocritical patients
- Author
-
Federico Verga, Pedro Grille, Osmar Telis, Alberto Biestro, and Nicolás Sgarbi
- Subjects
Tentorium cerebelli ,Computed tomography ,Neurosciences. Biological psychiatry. Neuropsychiatry ,Encephalocele ,Humans ,Medicine ,Cognitive Dysfunction ,Prospective Studies ,Hernia Cerebral ,medicine.diagnostic_test ,business.industry ,Encefalocele ,Anatomic Variation ,Magnetic resonance imaging ,Disfunción Cognitiva ,medicine.disease ,Tentorium Cerebelli ,Magnetic Resonance Imaging ,Tienda del Cerebelo ,Cerebral Herniation ,Concordance correlation coefficient ,Neurology ,Neurology (clinical) ,Dura Mater ,Mr images ,Tomography, X-Ray Computed ,Nuclear medicine ,business ,Cadaveric spasm ,Variación Anatómica ,Cerebral herniation ,Duramadre ,RC321-571 - Abstract
Background: Cadaveric studies on humans have shown anatomical variabilities in the morphometric characteristics of the tentorial notch. These anatomical variations could influence the worsening of neurocritical patients. Objectives: 1) To investigate the morphometric characteristics of the tentorial notch in neurocritical patients using computed tomography (CT); 2) To investigate the correlation between tentorial notch measurements by CT and by magnetic resonance imaging (MRI); and 3) To analyze the individual variability of the tentorial notch anatomy seen in neurocritical patients. Methods: Prospective series of neurocritical patients was examined. An imaging protocol for measurements was designed for CT and MRI. The level of the agreement of the measurements from CT and MR images was established. According to the measurements found, patients were divided into different types of tentorial notch. Results: We studied 34 neurocritical patients by CT and MRI. Measurements of the tentorial notch via CT and MRI showed significant agreement: concordance correlation coefficient of 0.96 for notch length and 0.85 for maximum width of tentorial notch. Classification of tentorial notch measurements according to the criteria established by Adler and Milhorat, we found the following: 15 patients (58%) corresponded to a "short" subtype; 7 (21%) to "small"; 3 (9%) to "narrow"; 2 (6%) to "wide"; 2 (6%) to “large”; 1 (3%) to “long”; and 4 (12%) to "typical". Conclusions: The anatomical variability of the tentorial notch could be detected in vivo by means of CT scan and MRI. Good agreement between the measurements made using these two imaging methods was found. RESUMEN Antecedentes: Estudios cadavéricos en humanos han mostrado variabilidad anatómica en las características morfométricas de la hendidura tentorial (HT). Estas variaciones anatómicas podrían influir en el neurodeterioro agudo de los pacientes neurocríticos. Objetivos: 1) Investigar las características morfométricas de la HT en pacientes neurocríticos mediante tomografía computarizada (TC); 2) Investigar la correlación de las mediciones de la HT realizadas por TC y resonancia magnética (RM); 3) Analizar la variabilidad individual de la anatomía de la HT observada en pacientes neurocríticos. Métodos: Se examinó una serie prospectiva de pacientes neurocríticos. Se diseñó un protocolo de imágenes para mediciones por TC y RM. Se estableció la concordancia de las mediciones realizadas mediante TC y RM. Según las mediciones encontradas, los pacientes se dividieron en diferentes tipos de HT. Resultados: Estudiamos 34 pacientes neurocríticos por TC y RM. Las mediciones de la HT por TC y RM mostraron una concordancia significativa: coeficiente de correlación de concordancia de 0,96 para la longitud de la HT y 0,85 para el ancho máximo de la HT. Clasificando las medidas de la HT de acuerdo con los criterios establecidos por Adler y Milhorat, encontramos: 15 pacientes (58%) correspondieron al subtipo "corto", 7 (21%) al "pequeño", 3 (9%) al "estrecho" ", 2 (6%) a "ancho ", 2 (6%) al "grande ", 1 (3%) al "largo" y 4 (12%) al "típico". Conclusiones: Se pudo detectar variabilidad anatómica de la HT in vivo, mediante TC y RM. Se encontró una buena concordancia en las medidas obtenidas con ambos métodos imagenológicos.
- Published
- 2021