1. Plasma leptin measurements in epidemiological investigation: comparison of two commonly used assays and estimate of regression dilution bias
- Author
-
ROBERTO IACONE, Russo, O., Russo, P., Venezia, A., Varriale, V., Gerardi, M. C., Strazzullo, P., Iacone, Roberto, Russo, Ornella, P., Russo, A., Venezia, Varriale, Vincenzo, M. C., Gerardi, and Strazzullo, Pasquale
- Subjects
Adult ,Leptin ,Male ,blood, Male, Middle Aged, Radioimmunoassay ,Radioimmunoassay ,Enzyme-Linked Immunosorbent Assay ,Middle Aged ,Sensitivity and Specificity ,Bias ,Humans ,Adult, Aged, Bias (Epidemiology), Enzyme-Linked Immunosorbent Assay ,methods, Sensitivity and Specificity ,Female ,Epidemiologic Methods ,Aged ,methods, Epidemiologic Methods, Female, Humans, Leptin - Abstract
As leptin is the object of intensive clinical research, we compared the radio-immunological assay (RIA) and enzyme-linked immunosorbent assay (ELISA) commercially available for measuring its plasma concentration in humans (Study 1), and sought to determine the power of a single plasma leptin measurement to characterise adequately a subject within a population on the basis of its intra- and inter-individual variations (Study 2).Study 1--Plasma leptin concentrations were determined by means of RIA and ELISA in a sample of 80 males. The measurements obtained using the two methods were closely correlated (r = 0.942), but the bias of the means was 21.1 +/- 73.5\% (M +/- SD, p < 0.001) and indicated that the two assays were not in agreement with each other. As expected, there were strong statistical associations between plasma leptin and a number of anthropometric indices, but the slopes of the regression of leptin concentration was significantly steeper when measured by ELISA. Study 2--ELISA was used to measure plasma leptin concentrations in three different samples obtained from 12 males and 12 females at two-week intervals. The inter-individual variation in plasma leptin was much greater than its intra-individual variation (the ratio of intra-to inter-individual variance = 0.05 and 0.04 in males and females, respectively), thus suggesting that a single fasting measurement is sufficient to characterise an individual's plasma leptin level within a population.ELISA is at least as effective as RIA in measuring plasma leptin, and is fully suitable for epidemiological investigations. A single measurement made in the morning and under fasting conditions is sufficient to characterise an individual within a population.
- Published
- 2002