Search Results
2. Feasibility of Long-Term Closed-Loop Control: A Multicenter 6-Month Trial of 24/7 Automated Insulin Delivery.
- Author
-
Kovatchev B, Cheng P, Anderson SM, Pinsker JE, Boscari F, Buckingham BA, Doyle FJ 3rd, Hood KK, Brown SA, Breton MD, Chernavvsky D, Bevier WC, Bradley PK, Bruttomesso D, Del Favero S, Calore R, Cobelli C, Avogaro A, Ly TT, Shanmugham S, Dassau E, Kollman C, Lum JW, and Beck RW
- Subjects
- Adult, Diabetes Mellitus, Type 1 blood, Feasibility Studies, Female, Humans, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Male, Middle Aged, Pancreas, Artificial, Blood Glucose analysis, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Abstract
Background: In the past few years, the artificial pancreas-the commonly accepted term for closed-loop control (CLC) of blood glucose in diabetes-has become a hot topic in research and technology development. In the summer of 2014, we initiated a 6-month trial evaluating the safety of 24/7 CLC during free-living conditions., Research Design and Methods: Following an initial 1-month Phase 1, 14 individuals (10 males/4 females) with type 1 diabetes at three clinical centers in the United States and one in Italy continued with a 5-month Phase 2, which included 24/7 CLC using the wireless portable Diabetes Assistant (DiAs) developed at the University of Virginia Center for Diabetes Technology. Median subject characteristics were age 45 years, duration of diabetes 27 years, total daily insulin 0.53 U/kg/day, and baseline HbA1c 7.2% (55 mmol/mol)., Results: Compared with the baseline observation period, the frequency of hypoglycemia below 3.9 mmol/L during the last 3 months of CLC was lower: 4.1% versus 1.3%, P < 0.001. This was accompanied by a downward trend in HbA1c from 7.2% (55 mmol/mol) to 7.0% (53 mmol/mol) at 6 months. HbA1c improvement was correlated with system use (Spearman r = 0.55). The user experience was favorable with identified benefit particularly at night and overall trust in the system. There were no serious adverse events, severe hypoglycemia, or diabetic ketoacidosis., Conclusion: We conclude that CLC technology has matured and is safe for prolonged use in patients' natural environment. Based on these promising results, a large randomized trial is warranted to assess long-term CLC efficacy and safety.
- Published
- 2017
- Full Text
- View/download PDF
3. Multinational Home Use of Closed-Loop Control Is Safe and Effective.
- Author
-
Anderson SM, Raghinaru D, Pinsker JE, Boscari F, Renard E, Buckingham BA, Nimri R, Doyle FJ 3rd, Brown SA, Keith-Hynes P, Breton MD, Chernavvsky D, Bevier WC, Bradley PK, Bruttomesso D, Del Favero S, Calore R, Cobelli C, Avogaro A, Farret A, Place J, Ly TT, Shanmugham S, Phillip M, Dassau E, Dasanayake IS, Kollman C, Lum JW, Beck RW, and Kovatchev B
- Subjects
- Adolescent, Adult, Aged, Blood Glucose drug effects, Blood Glucose Self-Monitoring instrumentation, Blood Glucose Self-Monitoring methods, Female, Humans, Hypoglycemia prevention & control, Hypoglycemic Agents adverse effects, Insulin adverse effects, Internationality, Male, Middle Aged, Mobile Applications, Young Adult, Blood Glucose analysis, Diabetes Mellitus, Type 1 blood, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems, Pancreas, Artificial adverse effects, Smartphone
- Abstract
Objective: To evaluate the efficacy of a portable, wearable, wireless artificial pancreas system (the Diabetes Assistant [DiAs] running the Unified Safety System) on glucose control at home in overnight-only and 24/7 closed-loop control (CLC) modes in patients with type 1 diabetes., Research Design and Methods: At six clinical centers in four countries, 30 participants 18-66 years old with type 1 diabetes (43% female, 96% non-Hispanic white, median type 1 diabetes duration 19 years, median A1C 7.3%) completed the study. The protocol included a 2-week baseline sensor-augmented pump (SAP) period followed by 2 weeks of overnight-only CLC and 2 weeks of 24/7 CLC at home. Glucose control during CLC was compared with the baseline SAP., Results: Glycemic control parameters for overnight-only CLC were improved during the nighttime period compared with baseline for hypoglycemia (time <70 mg/dL, primary end point median 1.1% vs. 3.0%; P < 0.001), time in target (70-180 mg/dL: 75% vs. 61%; P < 0.001), and glucose variability (coefficient of variation: 30% vs. 36%; P < 0.001). Similar improvements for day/night combined were observed with 24/7 CLC compared with baseline: 1.7% vs. 4.1%, P < 0.001; 73% vs. 65%, P < 0.001; and 34% vs. 38%, P < 0.001, respectively., Conclusions: CLC running on a smartphone (DiAs) in the home environment was safe and effective. Overnight-only CLC reduced hypoglycemia and increased time in range overnight and increased time in range during the day; 24/7 CLC reduced hypoglycemia and increased time in range both overnight and during the day. Compared with overnight-only CLC, 24/7 CLC provided additional hypoglycemia protection during the day., (© 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.)
- Published
- 2016
- Full Text
- View/download PDF
4. Adjustment of Open-Loop Settings to Improve Closed-Loop Results in Type 1 Diabetes: A Multicenter Randomized Trial.
- Author
-
Dassau E, Brown SA, Basu A, Pinsker JE, Kudva YC, Gondhalekar R, Patek S, Lv D, Schiavon M, Lee JB, Dalla Man C, Hinshaw L, Castorino K, Mallad A, Dadlani V, McCrady-Spitzer SK, McElwee-Malloy M, Wakeman CA, Bevier WC, Bradley PK, Kovatchev B, Cobelli C, Zisser HC, and Doyle FJ 3rd
- Subjects
- Adult, Aged, Blood Glucose Self-Monitoring, Cross-Over Studies, Diabetes Mellitus, Type 1 blood, Female, Humans, Hypoglycemic Agents therapeutic use, Insulin therapeutic use, Male, Middle Aged, Treatment Outcome, Young Adult, Blood Glucose drug effects, Diabetes Mellitus, Type 1 drug therapy, Hypoglycemic Agents administration & dosage, Insulin administration & dosage, Insulin Infusion Systems
- Abstract
Context: Closed-loop control (CLC) relies on an individual's open-loop insulin pump settings to initialize the system. Optimizing open-loop settings before using CLC usually requires significant time and effort., Objective: The objective was to investigate the effects of a one-time algorithmic adjustment of basal rate and insulin to carbohydrate ratio open-loop settings on the performance of CLC., Design: This study reports a multicenter, outpatient, randomized, crossover clinical trial., Patients: Thirty-seven adults with type 1 diabetes were enrolled at three clinical sites., Interventions: Each subject's insulin pump settings were subject to a one-time algorithmic adjustment based on 1 week of open-loop (i.e., home care) data collection. Subjects then underwent two 27-hour periods of CLC in random order with either unchanged (control) or algorithmic adjusted basal rate and carbohydrate ratio settings (adjusted) used to initialize the zone-model predictive control artificial pancreas controller. Subject's followed their usual meal-plan and had an unannounced exercise session., Main Outcomes and Measures: Time in the glucose range was 80-140 mg/dL, compared between both arms., Results: Thirty-two subjects completed the protocol. Median time in CLC was 25.3 hours. The median time in the 80-140 mg/dl range was similar in both groups (39.7% control, 44.2% adjusted). Subjects in both arms of CLC showed minimal time spent less than 70 mg/dl (median 1.34% and 1.37%, respectively). There were no significant differences more than 140 mg/dL., Conclusions: A one-time algorithmic adjustment of open-loop settings did not alter glucose control in a relatively short duration outpatient closed-loop study. The CLC system proved very robust and adaptable, with minimal (<2%) time spent in the hypoglycemic range in either arm.
- Published
- 2015
- Full Text
- View/download PDF