1. Breast screening using 2D-mammography or integrating digital breast tomosynthesis (3D-mammography) for single-reading or double-reading--evidence to guide future screening strategies.
- Author
-
Houssami N, Macaskill P, Bernardi D, Caumo F, Pellegrini M, Brunelli S, Tuttobene P, Bricolo P, Fantò C, Valentini M, and Ciatto S
- Subjects
- Breast Neoplasms epidemiology, Breast Neoplasms pathology, Evidence-Based Medicine, False Negative Reactions, False Positive Reactions, Female, Humans, Italy epidemiology, Middle Aged, Predictive Value of Tests, Prognosis, Prospective Studies, Reproducibility of Results, Time Factors, Breast Neoplasms diagnostic imaging, Imaging, Three-Dimensional, Mammography methods, Mass Screening methods, Radiographic Image Interpretation, Computer-Assisted
- Abstract
Purpose: We compared detection measures for breast screening strategies comprising single-reading or double-reading using standard 2D-mammography or 2D/3D-mammography, based on the 'screening with tomosynthesis or standard mammography' (STORM) trial., Methods: STORM prospectively examined screen-reading in two sequential phases, 2D-mammography alone and integrated 2D/3D-mammography, in asymptomatic women participating in Trento and Verona (Northern Italy) population-based screening services. Outcomes were ascertained from assessment and/or excision histology or follow-up. For each screen-reading strategy we calculated the number of detected and non-detected (including interval) cancers, cancer detection rates (CDRs), false positive recall (FPR) measures and incremental CDR relative to a comparator strategy. We estimated the false:true positive (FP:TP) ratio and sensitivity of each mammography screening strategy. Paired binary data were compared using McNemar's test., Results: Amongst 7292 screening participants, there were 65 (including six interval) breast cancers; estimated first-year interval cancer rate was 0.82/1000 screens (95% confidence interval (CI): 0.30-1.79/1000). For single-reading, 35 cancers were detected at both 2D and 2D/3D-mammography, 20 cancers were detected only with 2D/3D-mammography compared with none at 2D-mammography alone (p<0.001) and 10 cancers were not detected. For double-reading, 39 cancers were detected at 2D-mammography and 2D/3D-mammography, 20 were detected only with 2D/3D-mammography compared with none detected at 2D-mammography alone (p<0.001) and six cancers were not detected. The incremental CDR attributable to 2D/3D-mammography (versus 2D-mammography) of 2.7/1000 screens (95% CI: 1.6-4.2) was evident for single and for double-reading. Incremental CDR attributable to double-reading (versus single-reading) of 0.55/1000 screens (95% CI: -0.02-1.4) was evident for 2D-mammography and for 2D/3D-mammography. Estimated FP:TP ratios showed that 2D/3D-mammography screening strategies had more favourable FP to TP trade-off and higher sensitivity, applying single-reading or double-reading, relative to 2D-mammography screening., Conclusion: The evidence we report warrants rethinking of breast screening strategies and should be used to inform future evaluations of 2D/3D-mammography that assess whether or not the estimated incremental detection translates into improved screening outcomes such as a reduction in interval cancer rates., (Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF