1. Measurements of the Interventricular Septum and Mitral Leaflet Length in Hypertrophic Cardiomyopathy Patients Who Underwent Surgical Myectomy: A Prospective Comparative Multimodality Imaging Study.
- Author
-
Fava AM, Mehta AR, Bauer A, Popovic Z, Thamilarasan M, Smedira NG, and Desai MY
- Subjects
- Humans, Middle Aged, Male, Female, Prospective Studies, Aged, Magnetic Resonance Imaging, Cine methods, Cardiac Surgical Procedures methods, Magnetic Resonance Imaging methods, Cardiomyopathy, Hypertrophic surgery, Cardiomyopathy, Hypertrophic diagnostic imaging, Ventricular Septum diagnostic imaging, Ventricular Septum surgery, Mitral Valve diagnostic imaging, Mitral Valve surgery, Echocardiography, Transesophageal methods, Multimodal Imaging, Echocardiography, Three-Dimensional methods
- Abstract
Transesophageal echocardiography (TEE) plays an important role for real-time procedural guidance during surgical smyectomy (SM) for hypertrophic obstructive cardiomyopathy (HOCM). We aimed to compare (1) interventricular septum (IVS) thickness using 2- (2D) and 3-dimensional (3D) intraoperative TEE and preoperative cardiac magnetic resonance (CMR) and (2) mitral valve (MV) leaflet length using 2D, 3D TEE, automatic quantification of mitral valve (AMVQ) and preoperative CMR. We prospectively studied 50 patients with HOCM (age 59 ± 12 years, 44% men) who underwent SM during 2018 to 2019. The maximal basal, mid, and distal anteroseptum (AS) and inferoseptum (IS) were measured by multiplanar 3D reconstruction on TEE and by short-axis imaging on preoperative CMR and classified as mild (≤18 mm), moderate (18 to 25 mm), or severe (≥25 mm) groups based on AS and IS thickness on CMR. MV leaflet lengths were evaluated by preoperative CMR and intraprocedural 2D TEE, zoom 3D TEE, and AMVQ (EchoPAC, General Electric, Wisconsin). There was a moderate correlation between AS and IS thickness on 3D TEE and CMR (R
2 = 0.46, p <0.01 and R2 = 0.41, p <0.01, respectively), with 3D TEE showing an average overestimation of 3.8 and 4.7 mm versus CMR. The 3D TEE overestimated 14 patients (56%) with mild thickness as moderate and 5 patients (22%) with moderate thickness as severe. Assuming 3D TEE as the gold standard, the closest correlation for anterior mitral leaflet length was with CMR (average overestimation by CMR of 0.5 mm [root mean square deviation (RMSE%) 17]), intermediate correlation with 2D TEE (average deviation of 0.6 mm [RMSE% 21]) and no correlation with AMVQ (average deviation of 0.7 mm [RMSE% 24]). In conclusion, 3D TEE overestimates IVS thickness versus CMR in patients with HOCM who underwent SM, with greater discrepancy in those with thinner IVS. There are significant differences in MV lengths measured using different imaging techniques., Competing Interests: Declaration of competing interest Dr. Desai is a consultant and has research agreements with Bristol Myers Squibb, cytokinetics, Tenaya, Viz-AI, and Edgewise. Dr. Smedira is a consultant for Bristol Myers Squibb. No industry support was utilized in the conduct of this study. The authors have no competing interests to declare., (Copyright © 2024 Elsevier Inc. All rights reserved.)- Published
- 2024
- Full Text
- View/download PDF