1. Safety and Clinical Performance of Biodegradable Polymer-Coated Ultra-Thin Everolimus-Eluting Stents in "Real-World" Patients: A Multicenter Registry (PERFORM-EVER).
- Author
-
Kasturi S, Polasa S, Sowdagar MA, Kumar P, Reddy T, Nichenamatla C, Singh S, and Reddy V
- Subjects
- Absorbable Implants, Adult, Aged, Everolimus pharmacology, Humans, Middle Aged, Polymers, Prosthesis Design, Registries, Retrospective Studies, Sirolimus pharmacology, Stents adverse effects, Treatment Outcome, Coronary Artery Disease complications, Coronary Artery Disease surgery, Drug-Eluting Stents adverse effects, Myocardial Infarction etiology, Percutaneous Coronary Intervention adverse effects, Thrombosis etiology
- Abstract
Background: Tetrilimus (Sahajanand Medical Technologies Limited, Surat, India) is a biodegradable polymer-coated everolimus-eluting stent with cobalt-chromium stent platform and ultra-thin (60 µm) strut thickness. We aimed to report 1-year safety and clinical performance of Tetrilimus everolimus-eluting stent in patients with coronary artery disease in "real-world" clinical practice., Methods: The PERFORMance of biodegradable polymer-coated ultra-thin EVERolimuseluting stents was an observational, multicenter, single-arm, and investigator-initiated retrospective registry. All "real-world" patients who had received Tetrilimus everolimuseluting stent between July-2015 and October-2016 at four study centers were analyzed. The data were collected retrospectively either by extraction from existing databases in consecutive fashion where index and follow-up data existed or the follow-up was obtained by telephonic contact. Primary endpoint was 1-year incidence of target lesion failure, which was defined as a composite endpoint of cardiac death, myocardial infarction, and target lesion revascularization by percutaneous or surgical methods. The Academic Research Consortium-defined stent thrombosis was assessed as additional safety endpoint., Results: During the study period, 815 Tetrilimus everolimus-eluting stents (1.4 ± 0.5 stent/ patient) were implanted to treat 735 coronary lesions (1.1 ± 0.3 stent/lesion) in 594 patients (mean age: 55.6 ± 12.1 years). The cumulative incidence of target lesion failure at 1-year follow-up was 3.7%, which included 9 (1.5%) cardiac deaths, 8 (1.4%) myocardial infarctions, and 5 (0.8%) target lesion revascularizations. There were 5 (0.8%) cases of probable stent thrombosis and 4 (0.7%) cases of possible stent thrombosis at 1-year follow-up., Conclusion: Low incidences of target lesion failure and stent thrombosis at 1-year followup indicates that biodegradable polymer-coated ultra-thin Tetrilimus everolimus-eluting stents may have encouraging safety and efficacy in unselected real-world patients with coronary artery disease, including those with high-risk characteristics and complex lesions.
- Published
- 2022
- Full Text
- View/download PDF