1. Electronic neutron personal dosemeters: their performance in mixed radiation fields in nuclear power plants.
- Author
-
Luszik-Bhadra M, Bartlett D, Boschung M, Coeck M, Curzio G, Derdau D, d'Errico F, Fiechtner A, Itié C, Kyllönen JE, Lacoste V, Lahaye T, Lindborg L, Molinos C, Reginatto M, Schuhmacher H, Tanner R, and Vanhavere F
- Subjects
- Dose-Response Relationship, Radiation, Electronics, Equipment Design, Equipment Failure Analysis, Germany, Radiation Dosage, Reproducibility of Results, Semiconductors, Sensitivity and Specificity, Surface Properties, Thermoluminescent Dosimetry methods, Neutrons, Nuclear Reactors, Occupational Exposure analysis, Radiation Protection methods, Thermoluminescent Dosimetry instrumentation
- Abstract
This work describes spectral distributions of neutrons obtained as function of energy and direction at four workplace fields at the Krümmel reactor in Germany. Values of personal dose equivalent H(p)(10) and effective dose E are determined for different directions of a person's orientation in these fields and readings of personal neutron dosemeters--especially electronic dosemeters--are discussed with respect to H(p)(10) and E.
- Published
- 2006
- Full Text
- View/download PDF