1. Validation of revised patient measures of safety: PMOS-30 and PMOS-10.
- Author
-
Louch G, Reynolds C, Moore S, Marsh C, Heyhoe J, Albutt A, and Lawton R
- Subjects
- Adult, Feedback, Female, Humans, Male, Psychometrics, Reproducibility of Results, Patient Safety standards, Patient Satisfaction statistics & numerical data, Surveys and Questionnaires standards
- Abstract
Objectives: There is growing evidence that patients can provide feedback on the safety of their care. The 44-item Patient Measure of Safety (PMOS) was developed for this purpose. While valid and reliable, the length of this questionnaire makes it potentially challenging for routine use. Our study aimed to produce revised, shortened versions of PMOS (PMOS-30 and PMOS-10), which retained the psychometric properties of the longer version., Participants: To produce a shortened diagnostic measure, we analysed data from 2002 patients who completed PMOS-44, and examined the reliability of the revised measure (PMOS-30) in a sample of 751 patients. To produce a brief standalone measure, we again analysed data from 2002 patients who completed PMOS-44, and tested the reliability and validity of the brief standalone measure (PMOS-10) in a sample of 165 patients., Methods: The process of shortening the questionnaire involved a combination of secondary data analysis (eg, Standard Deviation and inter-item correlations) and a consensus group exercise to produce PMOS-30 and examine face validity. Analysis of PMOS-30 data examined reliability (eg, Cronbach's alpha). Further secondary data analysis (ie, corrected item-total correlations) produced PMOS-10, and primary data collection assessed its reliability and validity (eg, Cronbach's alpha, analysis of variance)., Results: Fourteen items were removed to produce PMOS-30 and the percentage of negatively worded items was reduced from 57% to 33%. PMOS-30 demonstrated good internal reliability (α=0.89). The 10 items with the highest corrected item-total correlations across both PMOS-44 and PMOS-30 composed PMOS-10. PMOS-10 had good internal reliability (α=0.79), demonstrated convergent validity; however, discriminant validity was not established., Conclusions: Two revised, shortened versions of the original PMOS-44 (PMOS-30 and PMOS-10) were produced to capture patient feedback about safety in hospital. The measures demonstrated good reliability and validity, and preserved the psychometric properties of the original measure., Competing Interests: Competing interests: None declared., (© Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY. Published by BMJ.)
- Published
- 2019
- Full Text
- View/download PDF