1. Diagnostic accuracy of Ara h 2 for detecting peanut allergy in children.
- Author
-
Kansen HM, van Erp FC, Meijer Y, Gorissen DMW, Stadermann M, van Velzen MF, Keusters WR, Frederix GWJ, Knulst AC, van der CK, and Le TM
- Subjects
- Adolescent, Child, Child, Preschool, Cohort Studies, Female, Humans, Male, Peanut Hypersensitivity blood, Peanut Hypersensitivity immunology, Prospective Studies, Reference Values, 2S Albumins, Plant immunology, Antigens, Plant immunology, Immunoglobulin E blood, Peanut Hypersensitivity diagnosis
- Abstract
Background: Specific IgE to Ara h 2 is a diagnostic test for peanut allergy which may reduce the need for double-blind placebo-controlled food challenges (DBPCFC); however, guidance for using Ara h 2 in place of DBPCFCs has not been validated., Objective: To prospectively evaluate 1) diagnostic accuracy of previously published Ara h 2 cut-off levels to diagnose peanut allergy in children and 2) costs., Methods: A consecutive series of 150 children age 3.5 to 18 years was evaluated in secondary and tertiary settings in the Netherlands. sIgE to Ara h 2 was the index test, and oral peanut ingestion was the reference test. Oral peanut ingestion was home or supervised introduction for Ara h 2 ≤ 0.1, DBPCFC for 0.1-5.0 and open food challenge for ≥5.0. Costs were calculated using financial healthcare data., Results: A conclusive reference test was performed in 113 children (75%). Sixty-four children (57%) had peanut allergy, as confirmed by a DBPCFC (27/47) or an open challenge (37/50). Forty-nine children (43%) were considered peanut-tolerant after peanut introduction (19/19), a DBPCFC (20/47) or an open challenge (10/50). Area under the curve for Ara h 2 was 0.94 (95% CI 0.90-0.98). The diagnostic flow chart correctly classified 26/26 (100%; 84-100) of children with Ara h 2 ≤ 0.1 as peanut-tolerant and 34/35 (97%; 83-100) of children with Ara h 2 ≥ 5.0 as peanut-allergic. At a cut-off of ≤0.1 and ≥5.0, a sensitivity of respectively 100% (93-100) and 53% (38-67) was observed and a specificity of 53% (38-67) and 98% (87-100). Mean annual costs of the flow chart were estimated as €320-€636 per patient lower than following national allergy guidelines., Conclusions: In this diagnostic accuracy study, which did not take into account pretest probability, we have validated previously published Ara h 2 cut-off levels which are associated with peanut tolerance and allergy., (© 2021 The Authors. Clinical & Experimental Allergy published by John Wiley & Sons Ltd.)
- Published
- 2021
- Full Text
- View/download PDF