1. Endoscopic closure of a bronchopleural fistula after pneumonectomy with the Amplatzer occluder: a step forward?
- Author
-
Rauf Basyrov, Alexander Bazhenov, Igor Motus, and Anna Tsvirenko
- Subjects
Adult ,Lung Diseases ,Male ,Pulmonary and Respiratory Medicine ,medicine.medical_specialty ,Septal Occluder Device ,medicine.medical_treatment ,Bronchopleural fistula ,Thoracostomy ,030204 cardiovascular system & hematology ,03 medical and health sciences ,Pneumonectomy ,Postoperative Complications ,0302 clinical medicine ,Bronchoscopy ,medicine ,Thoracoscopy ,Humans ,Empyema ,Aged ,Retrospective Studies ,medicine.diagnostic_test ,Thoracic Surgery, Video-Assisted ,business.industry ,Middle Aged ,Pleural Diseases ,Pleural cavity ,medicine.disease ,Bronchial Fistula ,Endoscopy ,Surgery ,medicine.anatomical_structure ,030228 respiratory system ,Female ,Cardiology and Cardiovascular Medicine ,business - Abstract
OBJECTIVES A bronchopleural fistula after pneumonectomy is a relatively rare but very serious complication. The development of endoscopic methods of treatment opens a new page in treating this condition. The goal of this paper was to confirm that the atrial septal defect Amplatzer device can be used for bronchopleural fistula closure in properly selected patients. METHODS A retrospective study of 13 patients with bronchopleural fistula after pneumonectomy was performed. There were 11 men and 2 women aged 26–70 years. Right-sided fistulas occurred in 10 patients and left-sided fistulas occurred in 3. The underlying disease was lung cancer in 7 patients and pulmonary tuberculosis in 6. Video-assisted thoracoscopic surgery (N = 7) and open-window thoracostomy (N = 6) were used to treat the empyema. To treat occlusion of the bronchial fistulas, we used Amplatzer atrial septal defect occluders originally intended for closure of ventricular and interatrial septal defects. The occluder was inserted from the bronchus by flexible bronchoscopy with the patient under local anaesthesia, with the help of video-assisted thoracoscopy or through a window thoracostomy from the pleural cavity. RESULTS We noted 3 complications after the procedure. In 2 patients, displacement of the occluders required re-installation in 1 patient and latissimus dorsi muscle coverage in the other. In the third patient, the occluder became dislodged during severe exacerbation of tuberculosis that occurred after the patient violated the treatment regimen. She died of tuberculosis 6 months after the occluder was inserted. The course in the remaining 10 patients was uneventful. CONCLUSIONS Our experience suggests that the use of an atrial septal defect occluder for the treatment of a bronchial fistula after pneumonectomy is a reliable option.
- Published
- 2019
- Full Text
- View/download PDF