9 results on '"J Obergassel"'
Search Results
2. Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures.
- Author
-
Lemoine MD, Obergassel J, Jaeckle S, Nies M, Taraba S, Mencke C, Rieß J, My I, Rottner L, Moser F, Ismaili D, Reißmann B, Ouyang F, Kirchhof P, Rillig A, and Metzner A
- Subjects
- Humans, Male, Female, Middle Aged, Aged, Treatment Outcome, Catheter Ablation methods, Time Factors, Action Potentials, Electrophysiologic Techniques, Cardiac, Heart Rate, Pulmonary Veins surgery, Pulmonary Veins physiopathology, Cryosurgery methods, Cryosurgery adverse effects, Cryosurgery instrumentation, Atrial Fibrillation surgery, Atrial Fibrillation physiopathology, Atrial Fibrillation diagnosis, Recurrence, Reoperation statistics & numerical data
- Abstract
Aims: Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI., Methods and Result: A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation., Conclusion: During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar., Competing Interests: Conflict of interest: none declared., (© The Author(s) 2024. Published by Oxford University Press on behalf of the European Society of Cardiology.)
- Published
- 2024
- Full Text
- View/download PDF
3. A novel platform allowing for pulsed field and radiofrequency ablation: First commercial atrial fibrillation ablation procedures worldwide with and without general anesthesia.
- Author
-
Metzner A, Rottner L, Moser F, My I, Lemoine M, Wenzel JP, Obergassel J, Ismaili D, Schäfer S, Kirchhof P, Ouyang F, Reissmann B, and Rillig A
- Subjects
- Humans, Anesthesia, General, Treatment Outcome, Atrial Fibrillation surgery, Radiofrequency Ablation, Ablation Techniques, Catheter Ablation methods, Pulmonary Veins surgery
- Abstract
Competing Interests: Disclosures Dr Metzner and Dr Rillig received lecture honoraria from Medtronic. All other authors have no conflicts of interest to disclose.
- Published
- 2024
- Full Text
- View/download PDF
4. Repeat pulmonary vein isolation and anterior line ablation using a novel point-by-point pulsed-field ablation system.
- Author
-
Wenzel JP, Lemoine MD, Rottner L, My I, Moser F, Obergassel J, Nies M, Rieß J, Ismaili D, Nikorowitsch J, Ouyang F, Kirchhof P, Rillig A, Metzner A, and Reissmann B
- Subjects
- Humans, Female, Middle Aged, Aged, Male, Prospective Studies, Treatment Outcome, Heart Atria, Recurrence, Pulmonary Veins surgery, Atrial Fibrillation surgery, Catheter Ablation methods
- Abstract
Background: Pulsed-field ablation (PFA) is a nonthermal energy source for ablation of cardiac arrhythmias. This study investigated the prospective outcomes of a novel PFA generator in conjunction with a commercially available, contact force-sensing, focal ablation catheter., Objective: The purpose of this study was to assess the feasibility, safety, and lesion characteristics of point-by-point PFA in consecutive patients undergoing repeat ablation of atrial fibrillation (AF)., Methods: The study involved reisolation of pulmonary veins (PVs) with electrical reconnection and the creation of an anterior line (AL) in patients with anterior substrate or durable pulmonary vein isolation (PVI)., Results: In 24 patients (46% female; mean age 67 ± 10 years; 67% persistent AF), successful reisolation of 27 of 27 reconnected PVs (100%) was performed. In 19 patients, AL ablation was performed, with bidirectional block in 16 (84%), median ablation time 26 [21, 33] minutes, and first-pass bidirectional block in 13 patients (68%). Acute AL reconduction occurred in 8 of 19 patients (42%). Among these 8 patients, a subsequent sustained block of the AL was achieved in 5 (63%). Ultra-high-density electroanatomic mapping revealed homogeneous but relatively large low-voltage areas in the ablated regions. Median procedural, left atrial dwell, and fluoroscopy times were 100 [90, 109] minutes, 83 [75, 98] minutes, and 10 [8, 13] minutes, respectively. No major or minor complications occurred., Conclusion: This study demonstrated feasibility, acute efficacy, and safety of point-by-point PFA for repeat PVI and AL ablation. Further studies are warranted to assess the long-term durability and comparison with established ablation methods., (Copyright © 2023 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
5. Nonthermal Point-by-Point Pulmonary Vein Isolation Using a Novel Pulsed Field Ablation System.
- Author
-
Wenzel JP, Lemoine MD, Rottner L, My I, Moser F, Obergassel J, Nies M, Rieß J, Ismaili D, Nikorowitsch J, Ouyang F, Kirchhof P, Rillig A, Metzner A, and Reissmann B
- Subjects
- Humans, Pulmonary Veins surgery, Ablation Techniques
- Abstract
Competing Interests: Disclosures Dr Wenzel received funding from the German Foundation of Heart Research (F/29/19) and travel grants from Boston Scientific in each case unrelated to this project. Dr Lemoine received a research grant from Farapulse and was supported by the Research Promotion Fund of the Faculty of Medicine unrelated to this project. Dr Metzner received speaker’s honoraria and travel grants from Medtronic, Biosense Webster, Boston Scientific, and EPD Solutions/Philips and a research grant from Farapulse. Dr Rillig received travel grants, speaker fees, and consultant fees from Biosense Webster, Medtronic, Cardiofocus, Ablamap, and EPD Solutions/Philips (KODEX-EPD). Dr Reissmann received speaker’s honoraria and travel grants from Medtronic. The other authors report no conflicts.
- Published
- 2023
- Full Text
- View/download PDF
6. Acute lesion extension following pulmonary vein isolation with two novel single shot devices: Pulsed field ablation versus multielectrode radiofrequency balloon.
- Author
-
My I, Lemoine MD, Butt M, Mencke C, Loeck FW, Obergassel J, Rottner L, Wenzel JP, Schleberger R, Moser J, Moser F, Kirchhof P, Reissmann B, Ouyang F, Rillig A, and Metzner A
- Subjects
- Male, Humans, Middle Aged, Aged, Aged, 80 and over, Female, Treatment Outcome, Catheters, Pulmonary Veins surgery, Catheter Ablation adverse effects, Catheter Ablation methods, Atrial Fibrillation diagnosis, Atrial Fibrillation surgery
- Abstract
Introduction: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury., Methods: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay., Results: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA., Conclusion: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series., (© 2023 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC.)
- Published
- 2023
- Full Text
- View/download PDF
7. Novel Radiofrequency Balloon Catheter - Impact of Ablation Parameters on Single-Shot Isolation.
- Author
-
My I, Bordignon S, Butt M, Rottner L, Marc L, Moser F, Wenzel JP, Obergassel J, Schleberger R, Moser J, Dinshaw L, Kirchhof P, Reissmann B, Ouyang F, Chun KJ, Schmidt B, Rillig A, and Metzner A
- Subjects
- Humans, Male, Female, Treatment Outcome, Heart Atria, Catheters, Recurrence, Catheter Ablation methods, Atrial Fibrillation surgery, Pulmonary Veins surgery
- Abstract
Background: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI)., Methods and results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m
2 ) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃)., Conclusions: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.- Published
- 2023
- Full Text
- View/download PDF
8. Pulsed-field ablation-based pulmonary vein isolation: acute safety, efficacy and short-term follow-up in a multi-center real world scenario.
- Author
-
Lemoine MD, Fink T, Mencke C, Schleberger R, My I, Obergassel J, Bergau L, Sciacca V, Rottner L, Moser J, Kany S, Moser F, Münkler P, Dinshaw L, Kirchhof P, Reissmann B, Ouyang F, Sommer P, Sohns C, Rillig A, and Metzner A
- Subjects
- Humans, Male, Female, Follow-Up Studies, Fluoroscopy, Treatment Outcome, Recurrence, Pulmonary Veins surgery, Catheter Ablation adverse effects, Catheter Ablation methods, Atrial Fibrillation diagnosis, Atrial Fibrillation surgery
- Abstract
Purpose: Pulsed-field ablation (PFA) is a new energy source to achieve pulmonary vein isolation (PVI) by targeted electroporation of cardiomyocytes. Experimental and controlled clinical trial data suggest good efficacy of PFA-based PVI. We aimed to assess efficacy, safety and follow-up of PFA-based PVI in an early adopter routine care setting., Methods: Consecutive patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) underwent PVI using the Farawave® PFA ablation catheter in conjunction with three-dimensional mapping at two German high-volume ablation centers. PVI was achieved by applying 8 PFA applications in each PV., Results: A total of 138 patients undergoing a first PVI (67 ± 12 years, 66% male, 62% persistent AF) were treated. PVI was achieved in all patients by deploying 4563 applications in 546 PVs (8.4 ± 1.0/PV). Disappearance of PV signals after the first application was demonstrated in 544/546 PVs (99.6%). More than eight PFA applications were performed in 29/546 PVs (6%) following adapted catheter positioning or due to reconnection as assessed during remapping. Mean procedure time was 78 ± 22 min including pre- and post PVI high-density voltage mapping. PFA catheter LA dwell-time was 23 ± 9 min. Total fluoroscopy time and dose area product were 16 ± 7 min and 505 [275;747] cGy*cm
2 . One pericardial tamponade (0.7%), one transient ST-elevation (0.7%) and three groin complications (2.2%) occurred. 1-year follow-up showed freedom of arrhythmia in 90% in patients with paroxysmal AF (n = 47) and 60% in patients with persistent AF (n = 82, p = 0.015)., Conclusions: PFA-based PVI is acutely highly effective and associated with a beneficial safety and low recurrence rate., (© 2022. The Author(s).)- Published
- 2023
- Full Text
- View/download PDF
9. Pulmonary Vein Isolation by Pulsed-field Ablation Induces Less Neurocardiac Damage Than Cryoballoon Ablation.
- Author
-
Lemoine MD, Mencke C, Nies M, Obergassel J, Scherschel K, Wieboldt H, Schleberger R, My I, Rottner L, Moser J, Kany S, Wenzel JP, Moser F, Dinshaw L, Münkler P, Reissmann B, Ouyang F, Meyer C, Blankenberg S, Zeller T, Fabritz L, Rillig A, Metzner A, and Kirchhof P
- Subjects
- Humans, Treatment Outcome, Recurrence, Pulmonary Veins surgery, Atrial Fibrillation surgery, Cryosurgery adverse effects, Catheter Ablation adverse effects
- Published
- 2023
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.