1. Versatile Three-Level FC-NPC Converter With High Fault-Tolerance Capabilities: Switch Fault Detection and Isolation and Safe Postfault Operation.
- Author
-
Bennani-Ben Abdelghani, Afef, Ben Abdelghani, Hafedh, Richardeau, Frederic, Blaquiere, Jean-Marc, Mosser, Franck, and Slama-Belkhodja, Ilhem
- Subjects
ELECTRIC power system faults ,FAULT tolerance (Engineering) ,SWITCHING power supplies ,FIELD programmable gate arrays ,RENEWABLE energy sources - Abstract
This paper deals with a hybrid fault-tolerant converter topology. It is performed through the connection of a classical three-phase three-level neutral-point-clamped (3L-NPC) converter with a fourth three-level flying capacitor (3L-FC) leg. The 3L-FC leg actively balances the 3L-NPC neutral-point voltage. For normal operation mode, this paper proposes a mathematical design of the filter needed to connect these two different topologies. Experimentally, and thanks to the already existing decoupling capacitors of the 3L-NPC converter, this filter requires the addition of only one low size inductance. When one fault of the power switch of the 3L-NPC occurs, this paper proposes a hardware reconfiguration technique based on only two fuses and one thyristor per leg allows a safe postfault operation recovery. This is achieved thanks to a simple fault-detection method and a new technique that combines fault leg isolation and corresponding phase postfault connection to the neutral point. Also, a dedicated field-programmable gate array (FPGA)-based control of the reconfigured converter is synthetized to ensure power system availability under fault operation mode. The converter fault-tolerant capabilities are addressed through simulation results and original overall experimental validations of the fault detection and isolation and the postfault operation steps, carried out on a 15-kW prototype converter. [ABSTRACT FROM AUTHOR]
- Published
- 2017
- Full Text
- View/download PDF