16 results on '"Akashi YJ"'
Search Results
2. Safety and feasibility of zero-contrast transcatheter aortic valve implantation using balloon-expandable valves in patients with aortic stenosis and severe renal impairment: A single-center study.
- Author
-
Koga M, Izumo M, Kobayashi Y, Kai T, Okuno T, Sato Y, Kuwata S, Okuyama K, Ishibashi Y, Tanabe Y, and Akashi YJ
- Subjects
- Humans, Feasibility Studies, Contrast Media adverse effects, Aortic Valve diagnostic imaging, Aortic Valve surgery, Treatment Outcome, Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Aortic Valve Stenosis complications, Renal Insufficiency, Chronic complications, Renal Insufficiency, Chronic diagnosis, Renal Insufficiency, Chronic therapy
- Abstract
Background: Aortic stenosis (AS) and chronic kidney disease (CKD) can coexist. Repeat exposure to contrast media in patients undergoing transcatheter aortic valve implantation (TAVI) has latent mortality risks and increased risk for acute kidney injury. We aimed to assess our "zero-contrast TAVI" protocol for patients with advanced CKD., Methods: Consecutive patients with severe AS who underwent TAVI at a single center registry were enrolled. Zero-contrast TAVI group included patients who underwent TAVI without contrast and who had an estimated glomerular filtration rate <30 mL/min/1.73 m
2 . Conventional TAVI group included patients who underwent the regular TAVI procedure. Patients using balloon-expandable valves via transfemoral approach were analyzed. Baseline clinical and procedural characteristics and clinical outcomes were compared between two groups. The primary outcome was early safety as defined by Valve Academic Research Consortium Criteria. Secondary outcomes included the presence of severe prosthesis-patient mismatch, moderate or greater perivalvular leakage, and requirement for new dialysis (within 3 months)., Results: A total of 520 patients were analyzed. Among these, 32 (6 %) underwent zero-contrast TAVI and 488 (94 %) conventional TAVI. In the zero-contrast TAVI group, 12 patients (37.5 %) had to use 20.7 (11.0-31.2) mL of contrast media. There were no significant differences in the primary and secondary outcomes between zero-contrast TAVI and conventional TAVI groups (78.1 % vs. 86.8 %, P = 0.184 and 9.4 % vs. 8.1 %, P = 0.738 for the primary and secondary outcomes, respectively)., Conclusions: Zero-contrast TAVI is feasible, safe, and effective in patients with AS and stage 4 CKD., Competing Interests: Declaration of competing interest Dr. Izumo is a screening proctor at Edwards Lifesciences., (Copyright © 2023 Elsevier Inc. All rights reserved.)- Published
- 2024
- Full Text
- View/download PDF
3. Prevalence and Clinical Outcomes of Noncardiac Surgery After Transcatheter Aortic Valve Replacement.
- Author
-
Kai T, Izumo M, Okuno T, Kobayashi Y, Sato Y, Kuwata S, Koga M, Tanabe Y, Sakamoto M, and Akashi YJ
- Subjects
- Humans, Aged, Retrospective Studies, Prevalence, Risk Factors, Treatment Outcome, Aortic Valve surgery, Transcatheter Aortic Valve Replacement adverse effects, Aortic Valve Stenosis epidemiology, Aortic Valve Stenosis surgery, Aortic Valve Stenosis complications, Heart Valve Prosthesis Implantation adverse effects
- Abstract
Aortic stenosis is a prevalent valvular heart disease, especially in the older people. They often coexist with other co-morbidities, and noncardiac surgery carries a higher risk because of the underlying valve condition. Despite the growing concern about the safety and optimal management of noncardiac surgery post-transcatheter aortic valve replacement (TAVR), there is limited evidence on this matter. This study aims to assess the clinical outcomes of noncardiac surgeries after TAVR. This retrospective study included 718 patients who underwent TAVR. Of these, 36 patients underwent noncardiac surgery after TAVR. The primary end point was the incidence of cardiovascular adverse events post-TAVR and the secondary end point was the incidence of structural valve deterioration. Composite end points included disabling stroke, heart failure requiring hospitalization, and cardiac death as defined by Valve Academic Research Consortium 3. Most of these surgeries were orthopedic and classified as intermediate risk. All noncardiac surgeries were performed without perioperative adverse events. There was no observed structural valve deterioration, and the incidence of composite end points did not significantly differ between the surgical and nonsurgical groups during the follow-up period. Noncardiac surgery after TAVR can be performed safely and does not have a negative impact on prognosis. Further studies are warranted to determine the optimal strategy for noncardiac surgery after TAVR., Competing Interests: Declaration of Competing Interest Dr. Okuno reports speaker fees from Abbott Medical Japan and Medtronic, Dr. Izumo is a consultant of Edwards Lifesciences and Abbott Medical Japan, and Dr Kuwata is a consultant of Abbott Medical Japan. The remaining authors have no competing interests to declare., (Copyright © 2023 Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF
4. Prognostic Value of Electrocardiographic Left Ventricular Hypertrophy After Transcatheter Aortic Valve Implantation: Insights from the OCEAN-TAVI Registry.
- Author
-
Koga M, Izumo M, Yoneyama K, Akashi YJ, Yashima F, Tada N, Yamawaki M, Shirai S, Naganuma T, Yamanaka F, Ueno H, Tabata M, Mizutani K, Takagi K, Watanabe Y, Yamamoto M, and Hayashida K
- Subjects
- Male, Humans, Aged, 80 and over, Female, Prognosis, Hypertrophy, Left Ventricular diagnosis, Hypertrophy, Left Ventricular epidemiology, Hypertrophy, Left Ventricular etiology, Registries, Aortic Valve surgery, Treatment Outcome, Transcatheter Aortic Valve Replacement adverse effects, Aortic Valve Stenosis diagnosis, Aortic Valve Stenosis surgery, Aortic Valve Stenosis complications
- Abstract
Electrocardiogram (ECG) left ventricular hypertrophy (LVH) is associated with the prognosis of patients with aortic stenosis. However, the impact of the presence or absence of ECG-LVH on the clinical outcomes after transcatheter aortic valve implantation (TAVI) is limited. This study aimed to assess the prognostic value of ECG-LVH among patients with aortic stenosis treated by TAVI. A total of 1,667 patients who underwent TAVI were prospectively enrolled into the OCEAN-TAVI (Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation) registry. A total of 1,446 patients (mean age 84 years; 29.9% men) were analyzed. The Sokolow-Lyon index was used to determine the presence of ECG-LVH. LVH was also assessed using transthoracic echocardiography (TTE). We investigated the association between ECG-LVH and all-cause and cardiovascular mortality. This study identified ECG-LVH and TTE-LVH in 743 (51.5%) and 1,242 patients (86.0%), respectively. The Kaplan-Meier analysis revealed that all-cause mortality was significantly higher among patients without ECG-LVH than among those with ECG-LVH (log-rank p <0.001). In the multivariable analysis, the absence of ECG-LVH was independently associated with all-cause mortality (hazard ratio 1.98, 95% confidence interval 1.39 to 2.82, p <0.001), regardless of the presence or absence of TTE-LVH. Furthermore, the presence of TTE-LVH with the absence of ECG-LVH was observed in 575 patients (40%), which was associated with cardiovascular mortality (hazard ratio 2.84, 95% confidence interval 1.56 to 5.17, p <0.001). In conclusion, the absence of ECG-LVH was independently associated with an increased risk of all-cause mortality after TAVI. Risk stratification using both ECG-LVH and TTE-LVH is a useful predictor of adverse clinical outcomes after TAVI., Competing Interests: Declaration of Competing Interest The OCEAN-TAVI registry is supported by the following companies: Edwards Lifesciences, Abbott, Medtronic, Boston Scientific, and Daiichi-Sankyo. Drs. Tada, Naganuma, Shirai, Mizutani, Ueno, Tabata, Watanabe, Yamamoto, and Hayashida are clinical proctors for Edwards Lifesciences and Medtronic. Dr. Takagi is a clinical proctor at Edwards Lifesciences. Dr. Izumo is a screening proctor at Edwards Lifesciences. The remaining authors have no competing interests to declare., (Copyright © 2023 Elsevier Inc. All rights reserved.)
- Published
- 2023
- Full Text
- View/download PDF
5. Three-Year Clinical Impacts of Permanence, Resolution, and Absence of Newly-Developed Left Bundle Branch Block After Transcatheter Aortic Valve Replacement.
- Author
-
Sasaki K, Kuwata S, Izumo M, Koga M, Kai T, Sato Y, Okuno T, Kobayashi Y, Murata R, Tanabe Y, and Akashi YJ
- Subjects
- Humans, Bundle-Branch Block diagnosis, Bundle-Branch Block etiology, Bundle-Branch Block therapy, Arrhythmias, Cardiac, Aortic Valve surgery, Treatment Outcome, Electrocardiography, Risk Factors, Transcatheter Aortic Valve Replacement adverse effects, Aortic Valve Stenosis surgery, Pacemaker, Artificial
- Abstract
Competing Interests: Declaration of Competing Interest The authors have no conflicts of interest to declare.
- Published
- 2023
- Full Text
- View/download PDF
6. Bioprosthetic valve failure of the Inspiris Resilia valve during transcatheter valve implantation.
- Author
-
Kobayashi Y, Okuyama K, Kuwata S, Koga M, Izumo M, and Akashi YJ
- Subjects
- Humans, Aortic Valve surgery, Prosthesis Failure, Treatment Outcome, Prosthesis Design, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis, Bioprosthesis adverse effects, Transcatheter Aortic Valve Replacement adverse effects
- Published
- 2023
- Full Text
- View/download PDF
7. Influence of coronary artery disease and percutaneous coronary intervention on mid-term outcomes in patients with aortic valve stenosis treated with transcatheter aortic valve implantation.
- Author
-
Kaihara T, Higuma T, Izumo M, Kotoku N, Suzuki T, Kameshima H, Sato Y, Kuwata S, Koga M, Mitarai T, Watanabe M, Okuyama K, Kamijima R, Ishibashi Y, Yoneyama K, Tanabe Y, Harada T, and Akashi YJ
- Subjects
- Aortic Valve diagnostic imaging, Aortic Valve surgery, Humans, Treatment Outcome, Aortic Valve Stenosis diagnosis, Aortic Valve Stenosis surgery, Coronary Artery Disease complications, Coronary Artery Disease diagnosis, Coronary Artery Disease surgery, Percutaneous Coronary Intervention adverse effects, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background: A high frequency of coronary artery disease (CAD) is reported in patients with severe aortic valve stenosis (AS) who undergo transcatheter aortic valve implantation (TAVI). However, the optimal management of CAD in these patients remains unknown., Hypothesis: We hypothesis that AS patients with TAVI complicated by CAD have poor prognosis. His study evaluates the prognoses of patients with CAD and severe AS after TAVI., Methods: We divided 186 patients with severe AS undergoing TAVI into three groups: those with CAD involving the left main coronary (LM) or proximal left anterior descending artery (LAD) lesion (the CAD[LADp] group), those with CAD not involving the LM or a LAD proximal lesion (the CAD[non-LADp] group), and those without CAD (Non-CAD group). Clinical outcomes were compared among the three groups., Results: The CAD[LADp] group showed a higher incidence of major adverse cardiovascular and cerebrovascular events (MACCEs) and all-cause mortality than the other two groups (log-rank p = .001 and p = .008, respectively). Even after adjustment for STS score and percutaneous coronary intervention (PCI) before TAVI, CAD[LADp] remained associated with MACCE and all-cause mortality. However, PCI for an LM or LAD proximal lesion pre-TAVI did not reduce the risk of these outcomes., Conclusions: CAD with an LM or LAD proximal lesion is a strong independent predictor of mid-term MACCEs and all-cause mortality in patients with severe AS treated with TAVI. PCI before TAVI did not influence the outcomes., (© 2021 The Authors. Clinical Cardiology published by Wiley Periodicals LLC.)
- Published
- 2021
- Full Text
- View/download PDF
8. Impact of perioperative change in physical function on midterm outcomes after transcatheter aortic valve implantation.
- Author
-
Ashikaga K, Doi S, Yoneyama K, Watanabe M, Suzuki N, Kuwata S, Kaihara T, Koga M, Okuyama K, Kamijima R, Tanabe Y, Takeichi N, Watanabe S, Izumo M, Kida K, and Akashi YJ
- Subjects
- Aged, 80 and over, Aortic Valve Stenosis complications, Aortic Valve Stenosis epidemiology, Female, Follow-Up Studies, Frailty epidemiology, Frailty etiology, Humans, Incidence, Japan epidemiology, Male, Patient Readmission trends, Perioperative Period, Prognosis, Retrospective Studies, Risk Factors, Survival Rate trends, Time Factors, Treatment Outcome, Aortic Valve surgery, Aortic Valve Stenosis surgery, Exercise physiology, Frailty physiopathology, Risk Assessment methods, Transcatheter Aortic Valve Replacement
- Abstract
Preoperative frailty diminishes the potential for functional recovery after transcatheter aortic valve implantation (TAVI). However, perioperative changes in physical status and their impact on prognosis after TAVI have not previously been reported. Therefore, this study aimed to investigate whether perioperative changes in physical function affect prognosis in patients undergoing TAVI. We retrospectively reviewed 257 patients who underwent TAVI. The Short Physical Performance Battery (SPPB), an objective physical status assessment tool, was evaluated pre- and post-TAVI. Patients were divided into two groups: (i) patients whose SPPB score declined in the perioperative period (the decline group) and (ii) patients whose SPPB score did not decline in the perioperative period (the non-decline group). The primary endpoint was unplanned hospitalization owing to heart failure or cardiovascular death following TAVI. The mean follow-up period was 385 ± 151 days, mean age was 83.2 ± 5.8 years, and 67% of the patients were women. Sixteen patients required readmission owing to heart failure, and seven experienced cardiovascular-related death. Kaplan-Meier analysis revealed that the event-free rate was significantly lower in the decline group (log-rank, p = 0.006). A stepwise multivariate logistic regression analysis showed that a perioperative change in SPPB was significantly associated with primary endpoints (odds ratio, 1.51; 95% confidence interval, 1.12-2.04). Perioperative change in physical function was an independent risk factor for heart failure, hospitalization, or cardiovascular death following TAVI.
- Published
- 2021
- Full Text
- View/download PDF
9. Effect of Diastolic Flow Reversal Patterns on Clinical Outcomes Following Transcatheter Aortic Valve Implantation - An Intraprocedural Echocardiography Study.
- Author
-
Ota M, Izumo M, Mochizuki Y, Nishikawa H, Sato Y, Watanabe M, Kaihara T, Okuyama K, Kamijima R, Tanabe Y, Harada T, Shinke T, and Akashi YJ
- Subjects
- Aged, Aged, 80 and over, Aortic Valve diagnostic imaging, Aortic Valve surgery, Echocardiography, Echocardiography, Transesophageal, Female, Humans, Male, Retrospective Studies, Treatment Outcome, Aortic Valve Insufficiency surgery, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Heart Valve Prosthesis Implantation, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background: Although diastolic flow reversal (DFR) in the descending aorta, assessed via transesophageal echocardiography (TEE), is a simple and easy indicator for evaluating aortic regurgitation, the association between DFR pattern and clinical outcomes following transcatheter aortic valve implantation (TAVI) is unclear. The purpose of this study was to evaluate the effect of DFR patterns on clinical outcomes following TAVI., Methods and results: Two-hundred and eleven patients (mean age, 83.6±5.7 years; 69% female) who underwent TAVI were retrospectively assessed via intraprocedural TEE. DFR was evaluated using pulsed-wave Doppler in the descending aorta before and after TAVI. The primary endpoint was major adverse cardio-cerebrovascular events (MACCEs). Although only 7 patients (3.3%) had moderate or severe paravalvular leak, as assessed by color Doppler echocardiography, holo-DFR (HDFR) was observed in 33 patients (16.0%) after TAVI. MACCEs occurred in 40 patients during the median follow up of 282 days (interquartile range: 160-478 days). The estimated cumulative MACCE-free survival at 1 year was significantly lower in patients with HDFR than in those without HDFR. A Cox proportional hazards analysis revealed that HDFR after TAVI was independently associated with MACCEs., Conclusions: HDFR was associated with an increased risk of MACCEs after TAVI. DFR evaluated by intraprocedural echocardiography could serve as a simple and easy method for predicting clinical outcomes.
- Published
- 2021
- Full Text
- View/download PDF
10. A Novel 3-Dimensional Echocardiographic Transillumination Rendering With Transparency in the Evaluation of Paravalvular Leak After Transcatheter Aortic Valve Implantation.
- Author
-
Izumo M, Okuyama K, and Akashi YJ
- Subjects
- Aged, 80 and over, Aortic Valve diagnostic imaging, Aortic Valve surgery, Cardiac Catheterization, Humans, Male, Prosthesis Design, Transillumination, Treatment Outcome, Aortic Valve Insufficiency surgery, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis surgery, Echocardiography, Three-Dimensional, Heart Valve Prosthesis adverse effects, Heart Valve Prosthesis Implantation adverse effects, Transcatheter Aortic Valve Replacement adverse effects
- Published
- 2021
- Full Text
- View/download PDF
11. Cerebral infarction due to dispersal of aortic atheromas detected by transoesophageal echocardiography during transcatheter aortic valve implantation.
- Author
-
Koga M, Izumo M, Tanabe Y, and Akashi YJ
- Subjects
- Aged, 80 and over, Humans, Intraoperative Complications prevention & control, Male, Monitoring, Intraoperative methods, Preoperative Care methods, Risk Adjustment, Treatment Outcome, Aorta diagnostic imaging, Aortic Valve Stenosis complications, Aortic Valve Stenosis surgery, Atherosclerosis complications, Atherosclerosis diagnosis, Cerebral Infarction diagnostic imaging, Cerebral Infarction etiology, Echocardiography, Transesophageal methods, Intraoperative Complications diagnostic imaging, Plaque, Atherosclerotic diagnostic imaging, Transcatheter Aortic Valve Replacement adverse effects, Transcatheter Aortic Valve Replacement instrumentation, Transcatheter Aortic Valve Replacement methods
- Abstract
Transcatheter aortic valve implantation (TAVI) is a rapidly evolving treatment option with an inherent risk of causing cerebral infarctions. The mechanism of cerebral infarction during TAVI mainly involves embolisms from the aortic wall and valve. Transoesophageal echocardiography (TEE) is useful for detecting aortic atheromas. We present the case of a patient in whom the dispersal of aortic atheromas was monitored by TEE during TAVI. This report demonstrates the importance of preoperatively predicting embolisms from aortic atheromas in patients with severe aortic stenosis., Competing Interests: Competing interests: None declared., (© BMJ Publishing Group Limited 2020. No commercial re-use. See rights and permissions. Published by BMJ.)
- Published
- 2020
- Full Text
- View/download PDF
12. Effect of Immunosuppressive Therapy on Clinical Outcomes for Patients With Aortic Stenosis Following Transcatheter Aortic Valve Implantation.
- Author
-
Kaihara T, Izumo M, Kameshima H, Sato Y, Kuwata S, Koga M, Watanabe M, Okuyama K, Kamijima R, Ishibashi Y, Tanabe Y, Higuma T, Harada T, and Akashi YJ
- Subjects
- Aortic Valve surgery, Humans, Immunosuppression Therapy, Risk Factors, Treatment Outcome, Aortic Valve Stenosis surgery, Immunosuppressive Agents adverse effects, Transcatheter Aortic Valve Replacement
- Abstract
Background: Transcatheter aortic valve implantation (TAVI) is an established treatment for symptomatic patients with severe aortic stenosis (AS). Sometimes patients with severe AS taking immunosuppressants are encountered. The effect of immunosuppressive therapy on clinical outcomes in patients with AS following TAVI were investigated., Methods and results: In total, 282 consecutive patients with severe AS who underwent transfemoral TAVI from January 2016 to December 2018 at St. Marianna University School of Medicine were reviewed. They were divided into 2 groups: the immunosuppressants group (IM group) in which patients continually used immunosuppressive drugs (n=22) and the non-immunosuppressants group (non-IM group) (n=260). The composite endpoints of a major adverse cardiovascular and cerebrovascular event (MACCE) defined as non-lethal myocardial infarction, unstable angina pectoris, heart failure requiring hospitalization, stroke, and cardiovascular death were evaluated. There were no differences in the incidence of vascular access complications (32% vs. 20%, P=0.143) and the rate of procedure success (100% vs. 93%, P=0.377) between the IM and non-IM groups. During the median follow-up period of 567 (16-1,312) days after the TAVI procedure, there were no significant differences between the IM and non-IM groups in the incidence of infectious complications (14% vs. 9%, P=0.442) or MACCE (18% vs. 20%, respectively; P=0.845)., Conclusions: The use of IM after TAVI is not associated with increased vascular access complications or mid-term MACCE in patients with severe AS treated with TAVI.
- Published
- 2020
- Full Text
- View/download PDF
13. New-Generation Transcatheter Aortic Valves in Patients With Small Aortic Annuli - Comparison of Balloon- and Self-Expandable Valves in Asian Patients.
- Author
-
Okuyama K, Izumo M, Ochiai T, Kuwata S, Kaihara T, Koga M, Kamijima R, Ishibashi Y, Tanabe Y, Higuma T, Makkar R, Miyairi T, and Akashi YJ
- Subjects
- Aortic Valve surgery, Hemodynamics, Humans, Prosthesis Design, Treatment Outcome, Aortic Valve Stenosis surgery, Heart Valve Prosthesis, Transcatheter Aortic Valve Replacement
- Abstract
Background: Asian patients have smaller aortic annuli. Although 20-mm balloon-expandable (BE) transcatheter heart valves (THV) are manufactured for transcatheter aortic valve implantation (TAVI) in these cases, the supra-annular design of self-expandable (SE) THV is considered more suitable; however, real-world comparative data are scarce., Methods and results: Consecutive TAVI cases (n=330) in a single Japanese center were reviewed. Based on the cutoff for the new-generation 20-/23-mm BE-THV, a small aortic annulus was defined as <330 mm
2 . A considerable number of patients had small annuli: 49/302 (16%). Of these, 33 BE-THV and 13 SE-THV using new-generation valves were compared. Although the SE-THV group had smaller annulus area (median 297 (interquartile range, 280-313) vs. 309 (303-323) mm2 (P=0.022)), it had more favorable post-procedural parameters; for SE-THV and BE-THV, respectively, effective orifice area (EOA), 1.5 (1.3-1.6) vs. 1.1 cm2 (0.9-1.3) (P=0.002); mean pressure gradient, 7.6 (5.6-11.0) vs. 14.2 mmHg (11.2-18.8) (P=0.001); and peak velocity, 1.8 (1.6-2.4) vs. 2.7 m/s (2.3-3.1) (P=0.001). Although new left bundle branch block was higher with SE-THV (24% and 62%, P=0.02), patient-prosthesis mismatch (PPM) ≥ moderate (indexed EOA <0.85 cm2 /m2 ) was significantly less with SE-THV than with BE-THV (8% vs. 55%; P=0.04). Hemodynamic findings were consistent up to 1 year., Conclusions: Small annuli are often seen in Asian patients, for whom SE-THV implantation results in favorable hemodynamics with less PPM.- Published
- 2020
- Full Text
- View/download PDF
14. Comparison in Clinical Outcomes Between Leadless and Conventional Transvenous Pacemaker Following Transcatheter Aortic Valve Implantation.
- Author
-
Okuyama K, Izumo M, Sasaki K, Kuwata S, Kaihara T, Watanabe M, Koga M, Kamijima R, Takano M, Ishibashi Y, Tanabe Y, Higuma T, Harada T, and Akashi YJ
- Subjects
- Aged, 80 and over, Aortic Valve surgery, Female, Humans, Male, Risk Factors, Treatment Outcome, Aortic Valve Stenosis diagnosis, Aortic Valve Stenosis surgery, Atrial Fibrillation diagnosis, Atrial Fibrillation therapy, Atrioventricular Block, Heart Valve Prosthesis, Pacemaker, Artificial, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Objectives: Atrioventricular block is a common complication of transcatheter aortic valve implantation (TAVI). Although conventional transvenous dual-chamber (DDD) pacemaker (PM) is ideal for atrioventricular block, leadless PM, which is less invasive, may be suitable for frail TAVI patients. Little is known about clinical outcomes of this newer device following TAVI., Methods: A total of 330 consecutive patients undergoing TAVI were reviewed. Of these, PM cases without atrial fibrillation were studied. Indication for leadless PM was based on heart team discussion., Results: PM implantations were performed in 30 patients (9.1%), and 24 patients (7.3%) had no atrial fibrillation. These 24 patients had 14 DDD-PMs and 10 leadless PMs, and formed the two study groups. Baseline characteristics were similar except for ejection fraction: median ages were 83.0 years (IQR, 81.0-87.0 years) vs 86.5 years (IQR, 83.5-90.3) (P=.18); 11 (78.6%) vs 8 (80%) were women (P=.67); Society of Thoracic Surgeons scores were 5.1% (IQR, 3.8%-5.9%) vs 5.3% (IQR, 3.4%-8.5%) (P=.82); and ejection fractions were 68.0% (IQR, 66.0%-70.5%) vs 59.0% (IQR, 52.8%-69.3%) (P=.049), for the DDD-PM and leadless PM groups, respectively. There was 1 case of atrial lead dislodgment in the DDD-PM group; otherwise, no complications related to the implantation procedure were found. The leadless PM group showed numerically shorter hospital stay: 12.5 days (range, 9.0-17.8 day) in the DDD-PM group vs 10.5 days (range, 7.8-15.3 days) in the leadless PM group (P=.44). Six-month follow-up revealed no significant differences in incidence of heart failure rehospitalizations or deaths: 2 (14.3%) in the DDD-PM group vs 2 (25%) in the leadless PM group (P=.47); and 2 (14.3%) in the DDD-PM group vs 0 (0%) in the leadless PM group (P=.39), respectively., Conclusions: Patients with leadless PM following TAVI may have shorter hospital stays, and clinical outcomes can be comparable with DDD-PMs. Leadless PMs may therefore be a reasonable option for frail TAVI patients.
- Published
- 2020
- Full Text
- View/download PDF
15. "Avulsion Injury" of the Artery by a Suture-Mediated Closure System During Transcatheter Aortic Valve Implantation.
- Author
-
Kaihara T, Higuma T, Kuwata S, Koga M, Watanabe M, Okuyama K, Kamijima R, Izumo M, Ishibashi Y, Tanabe Y, and Akashi YJ
- Subjects
- Aortic Valve diagnostic imaging, Aortic Valve surgery, Femoral Artery surgery, Humans, Sutures adverse effects, Treatment Outcome, Aortic Valve Stenosis diagnosis, Aortic Valve Stenosis surgery, Heart Valve Prosthesis adverse effects, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
We describe a cut-down method that is useful in cases with calcification restricted to the region surrounding the puncture site in transcatheter aortic valve implantation patients with severe aortic stenosis.
- Published
- 2020
- Full Text
- View/download PDF
16. Clinical Impact of New-Onset Left Bundle-Branch Block After Transcatheter Aortic Valve Implantation in the Japanese Population - A Single High-Volume Center Experience.
- Author
-
Sasaki K, Izumo M, Kuwata S, Ishibashi Y, Kamijima R, Watanabe M, Kaihara T, Okuyama K, Koga M, Nishikawa H, Tanabe Y, Higuma T, and Akashi YJ
- Subjects
- Aged, Aged, 80 and over, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis mortality, Bundle-Branch Block diagnosis, Bundle-Branch Block mortality, Bundle-Branch Block therapy, Cardiac Pacing, Artificial, Female, Heart Failure epidemiology, Humans, Incidence, Japan epidemiology, Male, Patient Readmission, Retrospective Studies, Risk Assessment, Risk Factors, Time Factors, Treatment Outcome, Aortic Valve Stenosis surgery, Bundle-Branch Block epidemiology, Hospitals, High-Volume, Transcatheter Aortic Valve Replacement adverse effects
- Abstract
Background: Although left bundle-branch block (LBBB) is a known conduction disorder that occurs after transcatheter aortic valve implantation (TAVI), its clinical impact in the Japanese population remains unclear., Methods and results: Of the 298 consecutive patients who underwent TAVI from January 2016 to December 2018 in a high-volume center in Japan, 68 with prior or periprocedural permanent pacemaker implantation (PPI), pre-existing LBBB, death during hospitalization, aborted procedure, or incomplete data were excluded. Among the final cohort of 230 patients, new-onset LBBB occurred in 90 (39%) after TAVI and persisted at 1-month follow up in 29 patients (13%; persistent new-onset LBBB, PN-LBBB). On multivariable analysis, self-expandable valve (SEV) use was found to be the only predictor of PN-LBBB (odds ratio: 4.39, 95% confidence interval: 1.69-11.41, P=0.002). There were no differences between patients with and without PN-LBBB in terms of overall mortality (18.8% vs. 26.0%, log-rank P=0.90) or need for late PPI (4.0% vs. 3.5%, log-rank P=0.74), yet there was an increased re-admission rate for heart failure (HF) in the PN-LBBB group (15.6% vs. 8.0%, log-rank P=0.046) at a median follow up of 431 (interquartile range, 271-733) days., Conclusions: PN-LBBB following TAVI was not associated with mortality or late PPI, but with a higher incidence of HF-related re-hospitalization at the mid-term follow up.
- Published
- 2020
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.