1. Percutaneous coronary intervention before transcatheter aortic valve implantation: A propensity score matched analysis.
- Author
-
Khan SU, Dani SS, Ganatra S, Ahmed T, Agalan A, Khadke S, Agarwal S, Zaid S, Arshad HB, Zahid S, Shah AR, Goel SS, and Kleiman NS
- Subjects
- Humans, Male, Female, Treatment Outcome, Aged, 80 and over, Aged, Time Factors, Risk Factors, Risk Assessment, Retrospective Studies, Aortic Valve surgery, Aortic Valve diagnostic imaging, Aortic Valve physiopathology, Transcatheter Aortic Valve Replacement adverse effects, Transcatheter Aortic Valve Replacement mortality, Percutaneous Coronary Intervention adverse effects, Percutaneous Coronary Intervention mortality, Coronary Artery Disease mortality, Coronary Artery Disease therapy, Coronary Artery Disease diagnostic imaging, Propensity Score, Databases, Factual, Aortic Valve Stenosis surgery, Aortic Valve Stenosis mortality, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis physiopathology
- Abstract
Background: The role of percutaneous coronary intervention (PCI) in patients with stable coronary artery disease (CAD) who subsequently undergo transcatheter aortic valve replacement (TAVR) remains uncertain. Therefore, we conducted this study to assess the association of PCI before TAVR with mortality and cardiovascular outcomes., Methods: We used the TriNetX database (Jan 2012 - Aug 2022) and grouped patients into PCI (3 months or less) before TAVR and no PCI. We performed propensity score matched (PSM) analyses for outcomes at 30 days and 1 year., Results: Of 17,120 patients undergoing TAVR, 2322 (14 %) had PCI, and 14,798 (86 %) did not have PCI before TAVR. In the PSM cohort (2026 patients in each group), PCI was not associated with lower all-cause mortality at 30 days (HR: 1.25, 95 % CI: 0.82-1.90) or 1 year (HR: 1.02, 95 % CI: 0.83-1.24). Frequency of repeat PCI after TAVR was low in both no PCI vs. PCI (2.4 % vs. 1.2 %) at 1 year; PCI was associated with a lower rate of repeat PCI (HR: 0.49, 95 % CI: 0.30-0.80). Sensitivity analysis revealed an E-value of 3.5 for repeat PCI (E-value for lower CI for HR: 1.81). PCI was not linked to reductions in MI, heart failure exacerbation, all-cause hospitalization, major bleeding, or permanent pacemaker/implantable cardioverter defibrillator., Conclusion: This analysis showed that PCI prior to TAVR was not associated with improvement in all-cause mortality. However, PCI was associated with a reduced rate of repeat PCI at 1 year., Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2024 Elsevier Inc. All rights reserved.)
- Published
- 2024
- Full Text
- View/download PDF