1. Atrial-based pacing has no benefit over ventricular pacing in preventing atrial arrhythmias in adults with congenital heart disease.
- Author
-
Opic P, Yap SC, Van Kranenburg M, Van Dijk AP, Budts W, Vliegen HW, Van Erven L, Can A, Sahin G, De Groot NM, Witsenburg M, and Roos-Hesselink JW
- Subjects
- Adolescent, Adult, Age Factors, Arrhythmias, Cardiac diagnosis, Arrhythmias, Cardiac etiology, Arrhythmias, Cardiac physiopathology, Belgium, Cardiac Pacing, Artificial adverse effects, Chi-Square Distribution, Child, Female, Heart Defects, Congenital complications, Heart Defects, Congenital diagnosis, Heart Defects, Congenital physiopathology, Humans, Kaplan-Meier Estimate, Male, Multivariate Analysis, Netherlands, Proportional Hazards Models, Retrospective Studies, Risk Factors, Time Factors, Treatment Outcome, Young Adult, Arrhythmias, Cardiac prevention & control, Atrial Function, Cardiac Pacing, Artificial methods, Heart Defects, Congenital therapy, Ventricular Function
- Abstract
Aims: To determine whether atrial-based pacing prevents atrial arrhythmias in adults with congenital heart disease (CHD) compared with ventricular pacing., Methods and Results: All adult CHD patients from four participating centres with a permanent pacemaker were identified. Patients with permanent atrial arrhythmias at pacemaker implantation and patients who received a pacemaker for treatment of drug-refractory atrial arrhythmias were excluded. The final study population consisted of 211 patients (52% male, 36% complex CHD) who received a first pacemaker for sick sinus dysfunction (n = 82) or atrioventricular block (n = 129) at a median age of 24 years [interquartile range (IQR), 12-34]. A history of atrial arrhythmias at implantation was present in 49 patients (23%). Atrial-based pacing was the initial pacing mode in 139 patients (66%) while the others (34%) received ventricular pacing. During a median follow-up of 13 years (IQR, 7-21), 90 patients (43%) developed an atrial arrhythmia. Multivariate analysis demonstrated no significant effect of atrial-based pacing on subsequent atrial arrhythmias [hazard ratio (HR), 1.53; 95% confidence interval (CI), 0.91-2.56; P = 0.1]. Independent predictors of atrial arrhythmia were history of atrial arrhythmias (HR, 5.55; 95% CI, 3.47-8.89; P< 0.0001), older age (≥18 years) at pacemaker implantation (HR, 2.29; 95% CI, 1.29-4.04; P = 0.005), and complex CHD (HR, 1.57; 95% CI, 1.01-2.45; P = 0.04)., Conclusion: In contrast to the general population, atrial-based pacing was not associated with a lower incidence of atrial arrhythmia in adults with CHD.
- Published
- 2013
- Full Text
- View/download PDF