1. Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography.
- Author
-
Achenbach S, Goroll T, Seltmann M, Pflederer T, Anders K, Ropers D, Daniel WG, Uder M, Lell M, and Marwan M
- Subjects
- Aged, Body Weight, Coronary Stenosis physiopathology, Female, Germany, Heart Rate, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Radiographic Image Interpretation, Computer-Assisted, Sensitivity and Specificity, Severity of Illness Index, Cardiac-Gated Imaging Techniques, Coronary Angiography methods, Coronary Stenosis diagnostic imaging, Radiation Dosage, Tomography, Spiral Computed
- Abstract
Objectives: We sought to evaluate the diagnostic accuracy of a new prospectively electrocardiogram (ECG)-triggered high-pitch scan mode for coronary computed tomography angiography (CTA), which allows an effective dose of less than 1 mSv., Background: Coronary CTA provides increasingly reliable image quality, but the associated radiation exposure can be high., Methods: Seventy-five patients with suspected coronary artery disease and in sinus rhythm were screened for participation. After exclusion of 25 patients for body weight >100 kg or failure to lower heart rate to ≤ 60 beats/min, 50 patients were studied by prospectively ECG-triggered high-pitch spiral computed tomography (CT). Coronary CTA was performed using a dual-source CT system with 2 × 128 × 0.6-mm collimation, 0.28-s rotation time, a pitch of 3.4, 100-kVp tube voltage, and current of 320 mA. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within 1 cardiac cycle. Diagnostic accuracy for detection of coronary artery stenoses ≥ 50% diameter stenosis was determined by comparison to invasive coronary angiography. Per-patient diagnostic performance was the primary form of analysis., Results: In all 50 patients (34 males, 59 ± 12 years of age), imaging was successful. For the detection of 16 patients with at least 1 coronary artery stenosis, CT demonstrated a sensitivity of 100% (95% confidence interval [CI]: 79% to 100%) and specificity of 82% (95% CI: 65% to 93%). The positive predictive value was 72% (95% CI: 49% to 89%) and the negative predictive value was 100% (95% CI: 87% to 100%). Sensitivity was 100% (95% CI: 88% to 100%) and specificity was 94% (95% CI: 89% to 97%) on a per-vessel basis. Per-segment sensitivity was 92% (95% CI: 80% to 97%), and specificity was 98% (95% CI: 96% to 98%). Mean dose-length product for coronary CTA was 54 ± 6 mGy · cm, the effective dose was 0.76 ± 0.08 mSv (0.64 to 0.95 mSv)., Conclusions: In nonobese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides high diagnostic accuracy for the detection of coronary artery stenoses., (Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)
- Published
- 2011
- Full Text
- View/download PDF