1. Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer.
- Author
-
Evans ES, Prosnitz RG, Yu X, Zhou SM, Hollis DR, Wong TZ, Light KL, Hardenbergh PH, Blazing MA, and Marks LB
- Subjects
- Adult, Age Distribution, Aged, Aged, 80 and over, Comorbidity, Female, Humans, Middle Aged, North Carolina epidemiology, Prevalence, Risk Factors, Sex Distribution, Stroke Volume, Breast Neoplasms epidemiology, Breast Neoplasms radiotherapy, Medical Errors statistics & numerical data, Radiation Injuries epidemiology, Radiotherapy, Conformal statistics & numerical data, Risk Assessment methods, Ventricular Dysfunction, Left epidemiology
- Abstract
Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer., Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors on the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test., Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up "too deep" (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI > or =25 kg/m2 compared with patients of normal weight (47% vs. 28%, p = 0.068)., Conclusions: BMI > or =25 kg/m2 may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT-induced perfusion defects.
- Published
- 2006
- Full Text
- View/download PDF