1. Implementation of an in-house quantitative real-time polymerase chain reaction method for Hepatitis B virus quantification in West African countries.
- Author
-
Ghosh S, Sow A, Guillot C, Jeng A, Ndow G, Njie R, Toure S, Diop M, Mboup S, Kane CT, Lemoine M, Thursz M, Zoulim F, Mendy M, and Chemin I
- Subjects
- Antiviral Agents, Benzothiazoles, Costs and Cost Analysis, DNA Primers genetics, DNA, Viral analysis, DNA, Viral genetics, Diamines, Drug Monitoring methods, Follow-Up Studies, Gambia, Hepatitis B, Chronic drug therapy, Humans, Organic Chemicals metabolism, Quinolines, Reproducibility of Results, Senegal, Sensitivity and Specificity, Staining and Labeling methods, Tenofovir administration & dosage, Time Factors, Hepatitis B virus isolation & purification, Hepatitis B, Chronic virology, Real-Time Polymerase Chain Reaction methods, Viral Load methods
- Abstract
Hepatitis B virus (HBV) is a major cause of chronic liver disease worldwide. HBV infection is diagnosed by serological tests, while real-time polymerase chain reaction (qRT-PCR) assays are used to quantify viral load, which is a crucial parameter to determine viral replication and to monitor antiviral treatments. However, measuring viral load in resource-limited countries remains nonsystematic, due to the high cost of commercial kits. Here, we describe the development, validation and implementation of a low-cost, in-house qRT-PCR assay to monitor HBV viral load in chronic carriers enrolled in the PROLIFICA programme in the Gambia and Senegal. Over 1500 HBsAg-positive patients, including 210 chronically infected HBV patients, who were given antiviral treatment (tenofovir), were monitored by qRT-PCR using the SYBR Green- and HBV-specific primers. Twenty-four tenofovir-treated patients were followed up and their viral load was tested every 3 months over the 12-month experimental time course. Compared to commercial assays, our in-house assay was shown to be (i) highly reliable, with good intra- and interassay reproducibility over a wide range (45-4.5 × 10
8 copies mL-1 ), (ii) very similar in the viral loads detected (R2 = .90), (iii) highly sensitive, as it detected loads as low as 30 copies mL-1 (~5 IU mL-1 ), (iv) cheaper (2- to 3-fold), (v) easier to implement and (vi) more rapid. Based on our experience, we recommend this assay as a reliable alternative to commercial assays, for monitoring HBV viraemia in resource-limited, highly endemic countries to reduce the cost and technical obstacles associated with commercial kits., (© 2016 John Wiley & Sons Ltd.)- Published
- 2016
- Full Text
- View/download PDF