1. Post-marketing Surveillance of a Quadrivalent Influenza Vaccine (Vaxigrip Tetra) in South Korea.
- Author
-
Lim, Sookyung, Li, Xiaoling, Syrkina, Olga, and Fournier, Marion
- Subjects
- *
INFLUENZA vaccines , *WATCHFUL waiting , *INFLUENZA viruses , *INFLUENZA - Abstract
Introduction: In 2017, a quadrivalent inactivated split-virion influenza vaccine (QIV; Vaxigrip Tetra®, Sanofi) was licensed in South Korea for active immunization against influenza A and influenza B viruses in individuals aged 3 years or older, which was subsequently extended to individuals aged 6 months or older in 2018. Post-marketing surveillance trials are mandatory in South Korea to retain drug licensure. Here, we assessed the safety of QIV in routine clinical practice in South Korea. Methods: This was an open, multicenter, observational, active safety surveillance study conducted between 20 June 2017 and 19 June 2021 at 10 study sites in South Korea in individuals aged 3 years or older who received a single dose of QIV during a routine healthcare visit. The participants or their legally acceptable representatives were instructed to record any adverse reactions (solicited events) and unsolicited non-serious adverse events (AE) in diary cards, and notify study investigators in case of serious adverse events (SAE). Results: Overall, 663 participants were included in this study. There were no AEs leading to study termination, and no SAEs reported. Injection site pain (278 [41.9%]) was the most frequent solicited injection site reaction, with myalgia (250 [37.7%]) and malaise (236 [35.6%]) the most frequent solicited systemic reactions. Grade 3 solicited injection site and systemic reactions were reported by 8 (1.2%) and 13 (2.0%) participants, respectively; most participants with solicited reactions recovered without the need for further action. Overall, 39 (5.9%) participants experienced 49 unsolicited non-serious AEs with the most frequently reported being nasopharyngitis (19 [2.9%]). Grade 3 unsolicited non-serious adverse events were reported in 1 (0.2%) participant. None of the unsolicited non-serious AEs were considered to be related to QIV. Conclusion: This post-marketing surveillance study confirms that QIV is well tolerated and has an acceptable safety profile in routine practice in South Korea. No unexpected safety concerns were identified. Trial Registration: ClinicalTrials.gov identifier NCT05406180. [ABSTRACT FROM AUTHOR]
- Published
- 2022
- Full Text
- View/download PDF