72 results on '"Ślosarek, Krzysztof"'
Search Results
52. Antioxidant activity and protective effects against oxidative damage of human cells induced by X-radiation of phenolic glycosides isolated from pepper fruits Capsicum annuum L.
- Author
-
Materska, Małgorzata, primary, Konopacka, Maria, additional, Rogoliński, Jacek, additional, and Ślosarek, Krzysztof, additional
- Published
- 2015
- Full Text
- View/download PDF
53. Dynamic-arc respiratory-gated stereotactic radiotherapy — technique presentation.
- Author
-
Woźniak, Grzegorz, Dolla, Łukasz, Ślosarek, Krzysztof, Bekman, Barbara, Latusek, Tomasz, and Głowacki, Grzegorz
- Subjects
TREATMENT of respiratory diseases ,STEREOTACTIC radiotherapy ,VOLUMETRIC-modulated arc therapy ,TUMOR surgery ,RADIATION doses ,RADIOLOGIC technology - Abstract
Main advancements in radiation treatment in recent years have included the introduction of dynamic techniques and 4D radiotherapy. The treatment of movable tumors relies on two important techniques: gating and tracking. The limitation of the former is the relatively short duration of the respiratory phase during which the radiation can be delivered and the need to teach the patient to breathe in accordance with the correct pattern. At the same time, certain clinical situations require the use of dynamic techniques. Intensity modulated radiotherapy (IMRT), combined with gantry rotation, forms the basis for the VMAT technique. The procedure usually takes a shorter time to complete than other dynamic techniques, which considerably improves patient comfort. The recently introduced True Beam
TM accelerator employs all the latest innovations in terms of dose-rate modeling and respiratory gating. [ABSTRACT FROM AUTHOR]- Published
- 2017
- Full Text
- View/download PDF
54. Napromienianie szpiku całego ciała — prezentacja metody
- Author
-
Głowacki, Grzegorz, primary, Miszczyk, Leszek, additional, Ślosarek, Krzysztof, additional, Jochymek, Bożena, additional, Woźniak, Grzegorz, additional, Matulewicz, Łukasz, additional, Radwan, Michał, additional, Leszczyńska, Paulina, additional, Dolla, Łukasz, additional, Najda, Jacek, additional, Krużel, Tomasz, additional, Czerw, Tomasz, additional, Saduś-Wojciechowska, Maria, additional, and Giebel, Sebastian, additional
- Published
- 2014
- Full Text
- View/download PDF
55. Wpływ energii wiązek fotonowych na rozkład dawek dla planów IMRT i VMAT
- Author
-
Radwan, Michał, primary, Grządziel, Aleksandra, additional, Hawrylewicz, Leszek, additional, Ślosarek, Krzysztof, additional, and Osewski, Wojciech, additional
- Published
- 2014
- Full Text
- View/download PDF
56. [Nr 78] Porównanie dwóch planów napromieniania guzów płuca wykonanych w jednej fazie oddechowej i wszystkich fazach w oparciu o 4DTK
- Author
-
Kulik, Roland, primary, Ślosarek, Krzysztof, additional, Trela, Krystyna, additional, and Gabryś, Dorota, additional
- Published
- 2013
- Full Text
- View/download PDF
57. [Nr 97] Wybór metody napromieniania w zależności od lokalizacji obszaru leczenia
- Author
-
Radwan, Michał, primary, Grządziel, Aleksandra, additional, Hawrylewicz, Leszek, additional, Ślosarek, Krzysztof, additional, and Osewski, Wojciech, additional
- Published
- 2013
- Full Text
- View/download PDF
58. [Nr 28] Kontrola jakości w technikach dynamicznych radioterapii
- Author
-
Ślosarek, Krzysztof, primary
- Published
- 2013
- Full Text
- View/download PDF
59. [Nr 61] Przedtransplantacyjne napromienianie całego szpiku z zastosowaniem systemu tomoterapii
- Author
-
Matulewicz, Łukasz, primary, Miszczyk, Leszek, additional, Giebel, Sebastian, additional, and Ślosarek, Krzysztof, additional
- Published
- 2013
- Full Text
- View/download PDF
60. Dose specification in External Beam Radiotherapy for CyberKnife and VMAT techniques applied to a case of prostate cancer.
- Author
-
Ślosarek, Krzysztof, Kopczyńska, Joanna, and Osewski, Wojciech
- Subjects
- *
PROSTATE cancer , *RADIOTHERAPY , *IRRADIATION , *DOSAGE forms of drugs , *TECHNOLOGICAL innovations - Abstract
Recent technological development in radiotherapy allows to introduce new irradiation techniques implemented on the conventional accelerators and on the machines such as CyberKnife (CK). These significantly changes the philosophy of planning and execution of radiotherapy. One of the fundamental concepts in radiotherapy is to define the therapeutic dose. It can be defined in the point, at the selected isodose, as an average value, or combined with the volume. We present the case of prostate cancer patient irradiated using CK machine and classic accelerator (VMAT). The differences in dose distribution and its value are shown. The analysis indicates that the average dose in Planning Treatment Volume (PTV) is a useful parameter during comparison of the dose distributions realized on machines of different type. [ABSTRACT FROM AUTHOR]
- Published
- 2016
- Full Text
- View/download PDF
61. Real time brachytherapy for prostate cancer – A new challenge for medical physicists
- Author
-
Ślosarek, Krzysztof, primary, Bystrzycka, Joanna, additional, and Fijałkowski, Marek, additional
- Published
- 2005
- Full Text
- View/download PDF
62. Dosimetry for linac with multileaf collimator
- Author
-
Ślosarek, Krzysztof, primary
- Published
- 1997
- Full Text
- View/download PDF
63. Extreme Heterogeneity Of Myeloablative Total Body Irradiation (TBI) Techniques Across Europe: A Survey Of Acute Leukemia Working Party Of The EBMT
- Author
-
Giebel, Sebastian, Miszczyk, Leszek, Slosarek, Krzysztof, Moukhtari, Leila, Ciceri, Fabio, Esteve, Jordi, Gorin, Norbert Claude, Labopin, Myriam, Nagler, Arnon, Schmid, Christoph, and Mohty, Mohamad
- Published
- 2013
- Full Text
- View/download PDF
64. The importance of the implant quality in APBI -- Gliwice experience. Dosimetric evaluation.
- Author
-
Cholewka, Agnieszka, Szlag, Marta, Białas, Brygida, Kellas-Ślęczka, Sylwia, and Ślosarek, Krzysztof
- Subjects
ACCELERATED partial breast irradiation ,CANCER radiotherapy research ,BREAST cancer treatment ,RADIATION dosimetry ,INTERSTITIAL brachytherapy - Abstract
This study includes four years of our clinical trials to improve implant quality in multicatheter accelerated partial breast irradiation (APBI). The progress in dosimetric and volumetric parameters of the treatment plans was evaluated. One hundred and ninety-one women, for whom treatment plans were made based on three dimensional imaging, were selected for the study. To evaluate progress made in our APBI procedure, following parameters and indices were taken into account: percentage of the target volume receiving the reference dose (PTV
ref ), minimum dose in the target volume expressed as a percentage of reference dose (PTVmin ), dose homogeneity index (DHI), and conformity index (COIN). Additionally, the plan quality index was calculated for every group as the sum of mean values of four evaluated parameters. PTVref have increased from the mean value of 83.4% at the beginning to recent 94.8%. The maximum value equals to 95.4%. The same trend can be observed with PTVmin value, which has been improved from 51.7% to 70.1%, maximally. DHI and COIN mean values present similar progress. DHI value increased from 0.53 level to 0.68, and COIN from 0.58 in 2009 to 0.74. Plan quality index has increased from 2.46 in 2009 to 3.06, recently. The implant quality is crucial for the accurate dose distribution. This paper shows the progress that was made in APBI procedure to improve implant quality. Nowadays, our implant technique is based on three-dimensional CT imaging results in acceptable dose distributions. [ABSTRACT FROM AUTHOR]- Published
- 2013
- Full Text
- View/download PDF
65. Vascular brachytherapy after percutaneous transluminal angioplasty of superficial femoral arteries -- one year observation.
- Author
-
Walichiewicz, Piotr, Piecuch, Jerzy, Białas, Brygida, Orkisz, Witold, Fijałkowski, Marek, Kozłowski, Andrzej, Rudnicki, Piotr, Karcz, Wojciech, Kuczmik, Wacław, Miszczyk, Leszek, and Ślosarek, Krzysztof
- Published
- 2002
66. Brachyterapia śródnaczyniowa po angioplastyce tętnic udowych powierzchownych -- wyniki 12-miesięcznej obserwacji.
- Author
-
Walichiewicz, Piotr, Piecuch, Jerzy, Białas, Brygida, Orkisz, Witold, Fijałkowski, Marek, Kozłowski, Andrzej, Rudnicki, Piotr, Karcz, Wojciech, Kuczmik, Wacław, Miszczyk, Leszek, and Ślosarek, Krzysztof
- Published
- 2002
67. Optymalizacja badań scyntygraficznych perfuzji mięśnia sercowego wykonywanych za pomocą gammakamery opartej na detektorach półprzewodnikowych na bazie tellurku kadmowo-cynkowego (CZT)
- Author
-
Budzyńska, Anna, Dziuk, Mirosław, Kopeć, Renata, Braziewicz, Janusz, and Ślosarek, Krzysztof
- Abstract
Wprowadzenie Na przestrzeni ostatnich kilkunastu lat w kardiologii nuklearnej obserwuje się odchodzenie od gammakamer SPECT ogólnego zastosowania na rzecz wyspecjalizowanych urządzeń, tzw. kamer kardiocentrycznych, zapewniających przede wszystkim dużo większą efektywność obrazowania. Przełomem było zastąpienie kryształów scyntylacyjnych NaI(Tl) detektorami półprzewodnikowymi CZT (tellurek kadmowo-cynkowy). Pierwsza w Europie Środkowo-Wschodniej instalacja skanera kardiologicznego z detektorami CZT, kolimacją zogniskowaną na sercu i układem detektorów pozwalających na przeprowadzenie stacjonarnej akwizycji 3D, miała miejsce w Warszawie, w Wojskowym Instytucie Medycznym (WIM). Cele pracy 1. Analiza ograniczeń skanera CZT, wynikających z zastosowanych rozwiązań konstrukcyjnych i technologicznych, w obrazowaniu pacjentów otyłych. 2. Ocena przydatności stosowania różnych metod pozwalających na redukcję artefaktów wynikających z pochłaniania promieniowania w tkankach miękkich pacjenta: korekcja atenuacji wykorzystująca tomografię komputerową CT z zewnętrznego urządzenia diagnostycznego oraz dodatkowa akwizycja SPECT perfuzji mięśnia sercowego w pozycji na brzuchu. 3. Przeprowadzenie symulacji artefaktów ruchowych i zweryfikowanie możliwości identyfikacji artefaktów na etapie oceny wizualnej oraz możliwości redukcji tych artefaktów. 4. Weryfikacja parametrów czynnościowych lewej komory serca na podstawie badań bramkowanych sygnałem EKG. 5. Ocena jakości badań perfuzyjnych SPECT mięśnia sercowego wykonanych w technologii półprzewodnikowej. Materiał i metody W celu realizacji powyższych zadań wykorzystano bazę badań pacjentów Zakładu Medycyny Nuklearnej WIM (Cele pracy, punkty 1., 2. i 5.), a także przeprowadzono badania z użyciem fantomu antropomorficznego tułowia z wkładką sercową (pkt 3.) oraz fantomu dynamicznego serca, umożliwiającego ustalenie wartości referencyjnych dla frakcji wyrzutowej (pkt 4.). Badania perfuzyjne mięśnia sercowego były opracowywane z wykorzystaniem oprogramowania Myovation (GE) na stacji Xeleris 3.0 lub 3.1. Badania bramkowane SPECT były dodatkowo opracowywane za pomocą aplikacji QGS (Quantitative Gated SPECT, Cedars-Sinai Medical Center). W celu realizacji punktu 3. wykorzystano również oprogramowanie Lister (GE) oraz MDC for Alcyone (Motion Detection and Correction for Alcyone, GE) na stacji Xeleris 3.1. W celu realizacji punktów 1., 2., 3., 5. analizowano badania perfuzyjne serca na podstawie 17-segmentowych map biegunowych z procentowymi wartościami perfuzji oraz przekroje w 3 osiach serca. Dodatkowo, w punkcie 2., analizowano mapy biegunowe z podziałem na ściany serca. Jakość badań perfuzyjnych mięśnia sercowego oceniana była przez czterech niezależnych sędziów (lekarze specjaliści medycyny nuklearnej) w 5-punktowej skali (0–4), gdzie 0 oznaczało obrazy niediagnostyczne, a 4 – obrazy bardzo dobrej jakości. Opracowanie każdego badania z kamery CZT poprzedzone było przeprowadzeniem kontroli jakości skanowania w celu oceny poprawności ułożenia serca w polu widzenia detektorów. Badania na skanerze CZT były wykonywane wg standardowego protokołu klinicznego (badanie na plecach, bez korekcji pochłaniania). W celu realizacji punktu 2. analizowano również badania perfuzyjne wykonane w pozycji pacjenta na brzuchu oraz badania z zastosowaniem korekcji atenuacji na podstawie CT. Do realizacji celów zdefiniowanych w punktach 4. i 5. wykorzystano również badania perfuzyjne SPECT mięśnia sercowego wykonane na konwencjonalnej dwugłowicowej gammakamerze (zarówno bez korekcji, jak i z korekcją pochłaniania promieniowania). Wyniki 1. W niniejszej pracy wykazano, że odsetek badań diagnostycznych wśród pacjentów z otyłością olbrzymią (BMI ≥ 40 kg/m2) wynosi 67% i jest dużo większy, niż to wynika z niektórych doniesień literaturowych. 2. Wykazano przydatność obydwu metod w redukcji artefaktów wynikających z braku korekcji pochłaniania promieniowania w badaniach ze skanera CZT: korekcja atenuacji oparta na skanach CT okazała się przydatna w identyfikacji artefaktów w ścianach dolnej i bocznej serca, a także przegrodzie międzykomorowej; metoda wykorzystująca dodatkową akwizycję z ułożeniem pacjenta na brzuchu okazała się pomocna w ocenie nieprawidłowości perfuzji w ścianie dolnej serca ze względu na redukcję atenuacji przeponowej. 3. W pracy zasymulowano artefakty wynikające z przesunięć i rotacji obrazowanego obiektu w czasie akwizycji. Pokazano, że artefakty ruchowe przybierają charakterystyczny wygląd na mapach biegunowych (np. artefakt powstały w wyniku przesunięcia w osi długiej pacjenta przypomina kształtem motyla) i przekrojach serca, co może ułatwić rozpoznanie artefaktów na etapie wizualnej oceny i zmniejszyć ryzyko błędnej interpretacji wyniku badania. Wykazano, że artefakty ruchowe mogą być skutecznie redukowane za pomocą dedykowanej aplikacji do korekcji ruchu. 4. W pracy wykazano silną korelację między parametrami czynnościowymi lewej komory serca wyznaczonymi dla badań ze skanera CZT i konwencjonalnej gammakamery. Zaobserwowano niewielki trend w kierunku niższych wartości frakcji wyrzutowej uzyskiwanych w badaniach na skanerze kardiologicznym. Wykazano, że wartości mierzonych parametrów zależą zarówno od zastosowanej metody rekonstrukcji obrazów, jak i użytego oprogramowania do analizy badań bramkowanych SPECT perfuzji serca. W przypadku badań ze skanera CZT największą i wysoką zgodność między wyznaczonymi wartościami frakcji wyrzutowych a wartościami referencyjnymi (tj. dla fantomu dynamicznego) uzyskano przy użyciu oprogramowania QGS (Lin’s CCC = 0,973; 95% PU: 0,959–0,982). 5. W pracy wykazano, że badania scyntygraficzne perfuzji serca wykonywane na skanerze kardiologicznym z detektorami CZT są lepszej jakości niż badania wykonywane na dwugłowicowej gammakamerze SPECT. Mimo 3-krotnie krótszej akwizycji i ok. 50-procentowej redukcji dawki w badaniu radioizotopowym, uzyskiwane za pomocą skanera CZT obrazy scyntygraficzne są bardzo dobrej jakości. Wnioski 1. Zastosowane w skanerze CZT rozwiązania konstrukcyjno-technologiczne nie stanowią podstawy do wykluczenia pacjentów z otyłością olbrzymią z badań na tym urządzeniu. 2. Korekcja pochłaniania wykorzystująca zewnętrzną tomografię komputerową i/lub wykonanie dodatkowej akwizycji w pozycji pacjenta na brzuchu są skutecznymi metodami redukcji artefaktów spowodowanych atenuacją. 3. Artefakty ruchowe mają charakterystyczny wzór na mapie biegunowej serca, co umożliwia identyfikację ruchu pacjenta. Możliwe jest zastosowanie korekcji ruchu albo powtórzenie akwizycji. 4. Skaner CZT pozwala w sposób miarodajny określić frakcję wyrzutową lewej komory serca. 5. Skaner z detektorami półprzewodnikowymi CZT pozwala na uzyskanie znacząco lepszych obrazów perfuzji mięśnia sercowego w porównaniu do badań z konwencjonalnych gammakamer z kryształami NaI(Tl)., Introduction For the last several years in nuclear cardiology we have been observing a widespread movement from general-purpose to more specialised cardiac-centered SPECT gamma cameras. This is mainly due to the higher imaging efficacy of the latter. The replacement of scintillation crystals NaI(Tl) with semiconductor CZT (cadmium zinc telluride) detectors was a major breakthrough. The first cardiac scanner with CZT detectors, collimation focused on the heart and a fixed array of detectors enabling stationary 3D acquisition in East-Central Europe was installed in the Military Institute of Medicine (Warsaw, Poland). Aims 1. Evaluation of technological and construction limitations of a CZT camera in imaging of obese patients. 2. Evaluation of different methods for a reduction of attenuation artifacts: attenuation correction based on transmission scans from a standalone CT device and additional myocardial perfusion imaging performed with a patient in a prone position. 3. Simulation of motion artifacts, evaluation of their detectability early during the visual analysis and assessment of possibility of their reduction. 4. Examination of the left ventricle functional parameters obtained from ECG-gated acquisitions. 5. Assessment of quality of myocardial perfusion SPECT scans performed with the use of a semiconductor gamma camera. Material and methods Objectives no. 1, 2 and 5 were achieved with the use of the cardiac SPECT scans data base of the Department of Nuclear Medicine of the Military Institute of Medicine (Warsaw, Poland). Experiments with an anthropomorphic torso phantom with a heart insert were also performed (aim no. 3). A dynamic heart phantom was used to determine the reference ejection fraction values (aim no. 4). Xeleris 3.0/3.1 workstation with the Myovation (GE) software was used for image analysis. The ECG-gated scans were additionally assessed with the use of the QGS application (Quantitative Gated SPECT, Cedars-Sinai Medical Center). To achieve aim no. 3 the Lister (GE) application as well as the MDC for Alcyone (Motion Detection and Correction, GE) software package on Xeleris 3.1 workstation were also used. In order to achieve aims no. 1, 2, 3 and 5 cardiac scans were analysed on 17-segment polar maps with the percentage of perfusion and on slices parallel to the three heart axes. To reach aim no. 2 polar maps divided according to the heart walls were also evaluated. The quality of myocardial perfusion SPECT scans was independently assessed by four nuclear medicine specialists on a 5-point scale (0-4) where 0 was given to the lowest-quality images and 4 to the highest. In order to verify the correct heart alignment within the detector field a scan quality control (Scan QC) was performed prior to visual assessment of SPECT CZT images. Acquisition was performed according to a standard clinical protocol for a CZT camera (patient in supine position, no attenuation correction). To achieve aim no. 2 additional prone acquisition and attenuation correction based on transmission scans from a standalone CT device were also performed. To achieve aims no. 4 and 5 myocardial perfusion SPECT scans were also performed on a conventional dual-headed gamma camera (with and without attenuation correction). Results 1. The study showed that the percentage of diagnostic myocardial perfusion SPECT scans in patients with morbid obesity (BMI ≥ 40 kg/m2) is 67% which is higher than reported in literature. 2. Both assessed artifact reduction methods proved useful. Attenuation correction based on transmission scans from a standalone CT device showed artifacts in the inferior and lateral heart wall and in the septum. Prone acquisitions helped to detect the diaphragmatic attenuation artifacts (seen as abnormal perfusion in the inferior heart wall). 3. Simulation of both axial displacements and rotation showed that these motion artifacts yield characteristic patterns on heart slices and polar maps (e.g. long axis displacement artifact produces a butterfly shape). This may help to identify the motion artifacts early (during the visual analysis phase) and to avoid mistakes in image evaluation. Motion artifacts can be effectively reduced with the use of a dedicated application for motion correction. 4. The study showed a strong correlation between functional heart parameters measured with the use of a CZT camera and a conventional gamma camera. However, ejection fraction values tended to be lower on a CZT scanner. It was revealed that the parameters values depended both on a reconstruction algorithm and software for gated cardiac SPECT analysis. CZT ejection fraction values were closest to the reference standard (determined on a dynamic phantom) when QGS software was used (Lin’s CCC = 0.973; 95% CI: 0.959-0.982). 5. The study revealed that myocardial perfusion scans performed on a cardiac-centered CZT gamma camera present higher quality images that conventional dual-headed gamma camera scans. CZT scans show superior quality regardless a three times shorter acquisition time and a 50% dose reduction. Conclusions 1. Technology and construction of a CZT scanner allows for an effective assessment of patients with morbid obesity. 2. Attenuation artifacts can be effectively reduced with the use of transmission scans from a standalone CT device and/or additional prone imaging. 3. Motion artifacts show characteristic patterns on polar maps which enables their early detection during visual analysis. Motion correction may be then applied or acquisition may be repeated. 4. Left ventricle ejection fraction can be reliably determined with the use of a CZT camera. 5. Gamma cameras with semiconductor CZT detectors yield superior quality images when compared to conventional dual-headed gamma cameras with NaI(Tl) detectors., 119
- Published
- 2020
68. 224 - Computer programme izobiogy-2 for local control and late complication probability calculations
- Author
-
Slosarek, Krzysztof, Zajusz, Alaksander, and Bereza, Iwona
- Published
- 1995
- Full Text
- View/download PDF
69. Dozymetria i kontrola jakości skanującej wiązki protonowej na stanowisku gantry
- Author
-
Mojżeszek, Natalia, Olko, Paweł, Stolarczyk, Liliana, Szefliński, Zygmunt, and Ślosarek, Krzysztof
- Abstract
Zastosowanie ołówkowych wiązek skanujących (ang. Pencil Beam Scanning, PBS) umożliwiło praktyczną realizację radioterapii protonowej o modulowanej intensywności, co znacznie rozszerzyło możliwości leczenia wiązkami protonowymi. Wprowadzenie nowej techniki pociągnęło za sobą konieczność zastosowania nowych metod dozymetrii i kontroli jakości. W niniejszej pracy przedstawiono wyniki prac eksperymentalnych i obliczeniowych obejmujących w szczególności pomiary dawki głębokiej wiązki ołówkowej, kontrolę zasięgu wiązki oraz opracowanie fantomu dla kompleksowej kontroli jakości stanowiska terapii. Systemy planowania leczenia (TPS), bazujące na modelach analitycznych wiązki ołówkowej, wymagają wprowadzenia w fazie konfiguracji wartości integralnych dawek głębokich (ang. Integral Depth Dose, IDD), które reprezentują całkowitą energię deponowaną przez wiązkę ołówkową i produkty jej oddziaływań w wodzie. Dedykowane do pomiaru IDD płasko-równoległe komory jonizacyjne Bragg Peak Chamber (BPC, r = 4 cm) i Stingray (r = 6 cm) nie obejmują całego przekroju rozproszonej wiązki. Za pomocą symulacji Monte Carlo transportu wiązki ołówkowej dla energii w zakresie 70 – 226 MeV wyznaczono wydajność geometryczną komór jonizacyjnych (εg), która reprezentuje frakcję całkowitej energii przekazanej komorze o promieniu r w stosunku do energii przekazanej hipotetycznej komorze o nieskończonym promienieniu. Wykazano, że wartości εg zmieniają się wraz z energią wiązki protonowej i z głębokością. Najmniejsze wartości εg = 93,2% i εg = 96,2% wyznaczono dla energii 226 MeV na głębokości odpowiadającej połowie zasięgu wiązki, odpowiednio dla komór BPC i Stingray. Komory te mogą zostać wykorzystane do pomiaru IDD wiązki o energiach odpowiednio do 160 MeV i do 190 MeV, bez konieczności dodatkowej korekty. Do kontroli jakości zasięgu wiązek protonowych zastosowanie znalazły wielowarstwowe komory jonizacyjne (MLIC), które umożliwiają jednoczesny pomiar IDD na całej głębokości penetracji wiązki. Celem badań było wyznaczenie własności dozymetrycznych komercyjnego detektora MLIC Giraffe (IBA Dosimetry). Wykazano, że detektor ten jest czuły na zmiany zasięgu wiązki protonowej mniejsze niż 0,2 mm. Dodatkowo pokazano, że pomiar IDD jest możliwy na obszarze 25 mm wokół środka komór detektora Giraffe. Wartości zasięgu zmierzone za pomocą detektora Giraffe wykazują dobrą zgodność z pomiarami wykonywanymi w fantomie wodnym za pomocą BPC. Detektor Giraffe zastosowano do weryfikacji zasięgu obliczonego przez system TPS dla punktów przechodzących przez różną konfigurację tkanek fantomu antropomorficznego. Zgodność zmierzonego zasięgu z wartościami obliczonymi za pomocą systemu TPS wynosi od -0,4 mm do 1,8 mm i zawiera się w przyjętej w praktyce klinicznej niepewności zasięgu równej 3,5% +1 mm. Dzienna kontrola jakości wiązek ołówkowych w Centrum Cyklotronowym Bronowice wykonywana jest za pomocą cylindrycznej komory jonizacyjnej Semiflex (PTW, Freiburg), dwuwymiarowego detektora scyntylacyjnego Lynx (IBA Dosimetry, Schwarzenbruck) oraz fantomu ISO Cube (CIRS Inc., Norfolk). W celu rozszerzenia zakresu testów kontroli jakości i ich przyspieszenia zaprojektowano, wykonano i przetestowano fantom PelicanQA. Zawiera on zestaw klinów PMMA do pomiaru zasięgu wiązki protonowej, fantom do pomiarów dawki oraz znacznik do testów zbieżności wiązki z izocentrum obrazowania. Wykazano, że fantom PelicanQA wraz z detektorem Lynx odwzorowuje zmiany zasięgu wiązki z dokładnością do 0,4 mm. Fantom PelicanQA umożliwia wykonanie dotychczasowych testów bez konieczności zmiany konfiguracji pomiarowej, co skróciło czas potrzebny na przeprowadzenie dziennych testów kontroli jakości wiązki z 35 do 25 minut., The pencil beam scanning (PBS) technique is applied to Modulated Proton Therapy (IMPT), the most advanced form of proton cancer radiotherapy. Highly conformal dose delivery to the tumour volume is achieved while sparing neighbouring healthy tissues. PBS has significantly expanded the clinical applications of proton therapy. However, it requires that new dosimetry and quality assurance procedures be developed. In this work, the research concerning depth dose distributions measurements for commissioning of the treatment planning system, testing beam range monitoring instruments and developing a dedicated phantom for daily quality assurance, is presented. To commission a treatment planning system (TPS) which uses an analytical beam model, a set of integral depth dose distributions (IDD) in water for different proton energies is required as input. In IDD measurements the gold standard is to apply large-area plane-parallel ionization chambers (IC): the PTW Bragg Peak Chamber (BPC) or the IBA Stingray (of effective radii 4 cm and 6 cm respectively). However, these chambers are too small to entirely cover the scattered proton beam. Therefore, the FLUKA Monte Carlo (MC) transport code was applied to calculate the geometrical efficiency (εg) of these chambers which represents the fraction of total beam energy measured by the IC, as compared to the output of an IC of an infinitely large radius. MC calculations were performed for pencil beams of energies ranging between 70 MeV and 226 MeV. It was shown that the value of the MC-determined εg depends on the proton beam depth in water and on its initial energy. The lowest εg values of 93.2% and 96.2%, at 226 MeV proton energy, were obtained for the BPC and the Stingray, respectively. For pencil beams available in our Cyclotron Centre Bronowice (CCB), it was verified that the commercial Bragg Peak Chamber (PTW Freiburg) and the Stingray Chamber (IBA Dosimetry) may be used in IDD measurements up to 160 MeV and 190 MeV beam energy without any correction. For quality assurance of the proton range, multi–layer ionization chambers (MLIC) are used, allowing simultaneous measurements at all beam depths to be performed. The ability of the commercial MLIC detector Giraffe (IBA Dosimetry) to perform dosimetry tests was investigated. The Giraffe detector was found to be sensitive to range changes below 0.2 mm, thus being an accurate tool in WET measurements. It was verified that a 25 mm area around the centres of the Giraffe multi-chamber layers could be used for IDD measurements. The Giraffe detector was applied to verify TPS-calculated ranges in an anthropomorphic head phantom. A number of beam directions was chosen, traversing tissues of different densities. The obtained differences between measured and TPS-calculated ranges were between -0.4 mm and +1.8 mm and remained within clinically accepted range uncertainty 3.5% +1 mm. To perform the daily pencil beam quality assurance (QA) procedure at our CCB, the Semiflex (PTW, Freiburg) cylindrical IC, the Lynx (IBA Dosimetry, Schwarzenbruck) 2D scintillation detector, and the ISO Cube (CIRS Inc., Norfolk) phantom are used. In an effort to improve and speed-up this procedure and to extend the number of verified parameters of the PBS gantry treatment unit, the PelicanQA phantom was in-house designed, built and tested. The PelicanQA instrument consists of a dosimetry phantom, a set of plastic wedges and a metal marker to test beam collinearity. The Lynx detector equipped with plastic wedges is able to detect range shifts with an accuracy of 0.4 mm. Moreover, use of the developed phantom makes it possible to perform all QA tests in one configuration. This significantly reduces the time required to perform routine morning QA tests (from 35 minutes to 25 minutes)., 133
- Published
- 2018
70. Can high dose rates used in cancer radiotherapy change therapeutic effectiveness?
- Author
-
Konopacka M, Rogoliński J, Sochanik A, and Ślosarek K
- Abstract
Current cancer radiotherapy relies on increasingly high dose rates of ionising radiation (100-2400 cGy/min). It is possible that changing dose rates is not paralleled by treatment effectiveness. Irradiating cancer cells is assumed to induce molecular alterations that ultimately lead to apoptotic death. Studies comparing the efficacy of radiation-induced DNA damage and apoptotic death in relation to varying dose rates do not provide unequivocal data. Whereas some have demonstrated higher dose rates (single dose) to effectively kill cancer cells, others claim the opposite. Recent gene expression studies in cells subject to variable dose rates stress alterations in molecular signalling, especially in the expression of genes linked to cell survival, immune response, and tumour progression. Novel irradiation techniques of modern cancer treatment do not rely anymore on maintaining absolute constancy of dose rates during radiation emission: instead, timing and exposure areas are regulated temporally and spatially by modulating the dose rate and beam shape. Such conditions may be reflected in tumour cells' response to irradiation, and this is supported by the references provided.
- Published
- 2016
- Full Text
- View/download PDF
71. Integral dose: Comparison between four techniques for prostate radiotherapy.
- Author
-
Ślosarek K, Osewski W, Grządziel A, Radwan M, Dolla Ł, Szlag M, and Stąpór-Fudzińska M
- Abstract
Aim: Comparisons of integral dose delivered to the treatment planning volume and to the whole patient body during stereotactic, helical and intensity modulated radiotherapy of prostate., Background: Multifield techniques produce large volumes of low dose inside the patient body. Delivered dose could be the result of the cytotoxic injuries of the cells even away from the treatment field. We calculated the total dose absorbed in the patient body for four radiotherapy techniques to investigate whether some methods have a potential to reduce the exposure to the patient., Materials and Methods: We analyzed CyberKnife plans for 10 patients with localized prostate cancer. Five alternative plans for each patient were calculated with the VMAT, IMRT and TomoTherapy techniques. Alternative dose distributions were calculated to achieve the same coverage for PTV. Integral Dose formula was used to calculate the total dose delivered to the PTV and whole patient body., Results: Analysis showed that the same amount of dose was deposited to the treated volume despite different methods of treatment delivery. The mean values of total dose delivered to the whole patient body differed significantly for each treatment technique. The highest integral dose in the patient's body was at the TomoTherapy and CyberKnife treatment session. VMAT was characterized by the lowest integral dose deposited in the patient body., Conclusions: The highest total dose absorbed in normal tissue was observed with the use of a robotic radiosurgery system and TomoTherapy. These results demonstrate that the exposure of healthy tissue is a dosimetric factor which differentiates the dose delivery methods.
- Published
- 2014
- Full Text
- View/download PDF
72. Comparison of 2D- and 3D-guided implantation in accelerated partial breast irradiation (APBI).
- Author
-
Cholewka A, Szlag M, Ślosarek K, and Białas B
- Abstract
Purpose: In this study two different pre-planning methods (2D vs. 3D) were compared in respect to the implant quality as judged by volumetric and dose parameters of the treatment plans. The aim of this work was to evaluate the influence of the imaging modalities used for pre-planning purpose to the treatment plan quality., Material and Methods: Twenty-four patients treated with HDR multicatheter implants were randomly selected for experiment. All patients underwent breast conserving surgery. Flexible catheters were implanted into the breast through the template. Inter-catheter distance, number of planes and catheters were adjusted, in respect to the size and location of the target. Pre-planning was used to evaluate the implant geometry in respect to the target. Needles number and position were modified if necessary. There were two experimental subgroups consisted of 12 patients each. Different pre-planning procedure was employed in each group. In the first group 2D X-ray imaging system was used. In the second one the 3D pre-planning method based on CT was performed. Treatment plans were evaluated with parameters calculated based on dose-volume histograms (DVHs). Volumetric and dose parameters were used for comparison of the dose distribution between the two experimental subgroups., Results: The mean value of target coverage V
PTV 100 is higher for 3D pre-planning than for 2D (91.7% vs. 86.1%). The dose that covers 90% of the PTV (D90) is also higher for 3D pre-planning than for 2D (4.2 Gy vs. 3.6 Gy). Similar relation can be observed for the values of dose homogeneity index where DHI obtained for 3D pre-planning is 0.60 and 0.53 for 2D. All differences were statistically significant with p < 0.05., Conclusions: Analysis presented in this paper showed that 3D pre-planning method improves the geometrical quality of the implant.- Published
- 2009
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.