51. Fire performance of multi-storey wooden facades
- Author
-
Östman Birgit A.-L. and Tsantaridis Lazaros D.
- Subjects
Engineering (General). Civil engineering (General) ,TA1-2040 - Abstract
Two series of full scale fire tests of wooden facades according to the Swedish test SP Fire 105 are presented, one series for different shares of untreated wood (partial wood and structural fire protection with a fire shield above the window) and another series for fire retardant treated, FRT, wood. The results are compared with data from the Single Burning Item test and the cone calorimeter. For FRT wood, the need for verification of the weather durability of the treatment is stressed and a new European technical specification CEN/TS 15912 presented. The need to use fire stops behind multi-storey façade claddings to avoid fire spread in the cavities is underlined and the possibilities of fire safety design with sprinklers is briefly presented.
- Published
- 2013
- Full Text