101. MRI cine-tagging of cardiac-induced motion for noninvasive staging of liver fibrosis.
- Author
-
Lefebvre T, Petitclerc L, Hébert M, Bilodeau L, Sebastiani G, Olivié D, Gao ZH, Sylvestre MP, Cloutier G, Nguyen BN, Gilbert G, and Tang A
- Subjects
- Biopsy, Humans, Liver diagnostic imaging, Prospective Studies, ROC Curve, Elasticity Imaging Techniques, Liver Cirrhosis diagnostic imaging
- Abstract
Background: MR elastography is a noninvasive technique that provides high diagnostic accuracy for the staging of liver fibrosis; however, it requires external hardware and mainly assesses the right lobe., Purpose: To evaluate the diagnostic performance of MRI cine-tagging for staging fibrosis in the left liver lobe, using biopsy as the reference standard., Study Type: Institutional Review Board (IRB)-approved two-center prospective study., Population: Seventy-six patients with chronic liver disease who underwent an MRI cine-tagging examination and a liver biopsy within a 6-week interval., Field Strength/sequence: 2D-GRE multislice sequence at 3.0T with spatial modulation of the magnetization preparation sequence and peripheral pulse-wave triggering on two coronal slices chosen underneath the heart apex to capture maximal deformation with consecutive breath-holds adapted to patient cardiac frequency., Assessment: A region of interest was selected in the liver close to the heart apex. Maximal strain was evaluated with the harmonic phase (HARP) technique., Statistical Tests: Spearman's correlation, Kruskal-Wallis test, Mann-Whitney U-test, and receiver operating characteristic (ROC) analysis were performed., Results: Liver strain measured on tagged images decreased with higher histological fibrosis stage (ρ = -0.68, P < 0.0001). Strain values were significantly different between all fibrosis stages (P < 0.0001), and between groups of fibrosis stages ≤F3 vs. F4 (P < 0.05). Areas under the ROC curves were 0.95 (95% confidence interval: 0.89-1.00) to distinguish fibrosis stages F0 vs. F4, 0.81 (0.70-0.92) for stages F0 vs. ≥F1, 0.84 (0.76-0.93) for stages ≤F1 vs. ≥F2, 0.86 (0.78-0.94) for stages ≤F2 vs. ≥F3, and 0.87 (0.77-0.96) for stages ≤F3 vs. F4., Data Conclusion: MRI cine-tagging is a promising technique for measuring liver strain without additional elastography hardware. It could be used to assess the left liver lobe as a complement to current techniques assessing the right lobe., Level of Evidence: 1 Technical Efficacy: 3 J. Magn. Reson. Imaging 2020;51:1570-1580., (© 2019 International Society for Magnetic Resonance in Medicine.)
- Published
- 2020
- Full Text
- View/download PDF