151. One-year outcomes of patients undergoing complex percutaneous coronary intervention with three contemporary drug-eluting stents.
- Author
-
Azzalini L, Baber U, Johal GS, Farhan S, Barman N, Kapur V, Hasan C, Vijay P, Jhaveri V, Mehran R, Kini AS, and Sharma SK
- Subjects
- Everolimus adverse effects, Humans, Prosthesis Design, Treatment Outcome, Coronary Artery Disease diagnostic imaging, Coronary Artery Disease surgery, Drug-Eluting Stents, Myocardial Infarction, Percutaneous Coronary Intervention adverse effects
- Abstract
Objectives: We aimed to evaluate the 1-year outcomes of three everolimus-eluting stents (EES) for complex percutaneous coronary intervention (PCI)., Background: It is controversial whether contemporary bioresorbable-polymer drug-eluting stents (BP-DES) are associated with better outcomes compared with durable-polymer DES (DP-DES)., Methods: Patients undergoing PCI with cobalt-chromium (CoCr)-DP-EES (Xience), platinum-chromium (PtCr)-DP-EES (Promus), or PtCr-BP-EES (Synergy) at one high-volume institution between 2015 and 2017 were included. The primary endpoint was 1-year major adverse cardiac events (MACE), a composite of death, myocardial infarction, and target-vessel revascularization. Associations were also examined in patients undergoing complex PCI. Multivariable analysis was conducted to adjust for baseline differences across groups., Results: We included n = 5,446 patients (CoCr-DP-EES, n = 3,177; PtCr-DP-EES, n = 1,555; PtCr-BP-EES, n = 714). Patients treated with PtCr-BP-EES had higher comorbidity burden and procedural complexity. At 1 year, MACE rates were 8.9% for CoCr-DP-EES versus 8.9% for PtCr-DP-EES versus 8.6% for PtCr-BP-EES (p = .97). The incidence of definite/probable stent thrombosis (ST) was also similar (0.6 vs. 0.4 vs. 0.3%, p = .69). Complex PCI was performed in n = 2,894/5,446 (53.1%). At 1 year, MACE rates were 11.5 versus 10.7 versus 10.3%, respectively (p = .83). The incidence of definite/probable ST was also similar (0.9 vs. 0.3 vs. 0.3%, p = .22). On multivariable analysis, stent type was not an independent predictor of MACE either in the overall or in the complex PCI population., Conclusions: We observed comparable 1-year rates of MACE and definite/probable ST in patients undergoing PCI with CoCr-DP-EES, PtCr-DP-EES, and PtCr-BP-EES. Results were unchanged among patients undergoing complex PCI. Future multicenter randomized studies should confirm and extend our findings., (© 2020 Wiley Periodicals LLC.)
- Published
- 2021
- Full Text
- View/download PDF