201. Metallic Limus-Eluting Stents Abluminally Coated with Biodegradable Polymers: Angiographic and Clinical Comparison of a Novel Ultra-Thin Sirolimus Stent Versus Biolimus Stent in the DESTINY Randomized Trial.
- Author
-
Lemos PA, Abizaid AA, Meireles GC, Sarmento-Leite R, Prudente M, Cantarelli M, Dourado AD, Mariani J Jr, Perin MA, Costantini C, Costa RA, Costa JR, Chamie D, Campos CA, and Ribeiro E
- Subjects
- Aged, Brazil, Coronary Artery Disease diagnostic imaging, Coronary Artery Disease mortality, Coronary Restenosis etiology, Coronary Thrombosis etiology, Female, Humans, Male, Middle Aged, Myocardial Infarction etiology, Percutaneous Coronary Intervention adverse effects, Percutaneous Coronary Intervention mortality, Predictive Value of Tests, Prospective Studies, Prosthesis Design, Sirolimus administration & dosage, Time Factors, Treatment Outcome, Absorbable Implants, Cardiovascular Agents administration & dosage, Coated Materials, Biocompatible, Coronary Angiography, Coronary Artery Disease therapy, Coronary Vessels diagnostic imaging, Drug-Eluting Stents, Percutaneous Coronary Intervention instrumentation, Sirolimus analogs & derivatives
- Abstract
Aims: To evaluate the outcomes of patients treated with a new drug-eluting stent formulation with low doses of sirolimus, built in an ultra-thin-strut platform coated with biodegradable abluminal coating., Methods: This study is a randomized trial that tested the main hypothesis that the angiographic late lumen loss of the novel sirolimus-eluting stent is noninferior compared with commercially available biolimus-eluting stent. A final study population comprising 170 patients with one or two de novo lesions was randomized in the ratio 2:1 for sirolimus-eluting stent or biolimus-eluting stent, respectively. The primary endpoint was 9-month angiographic in-stent late lumen loss. Adverse clinical events were prospectively collected for 1 year., Results: After 9 months, the novel sirolimus-eluting stent was shown noninferior compared with the biolimus stent for the primary endpoint (angiographic in-stent late lumen loss: 0.20 ± 0.29 mm vs. 0.15 ± 0.20 mm, respectively; P value for noninferiority <0.001). The 1-year incidence of death, myocardial infarction, repeat revascularization, and stent thrombosis remained low and not significantly different between the groups., Conclusions: The present randomized trial demonstrates that the tested novel sirolimus-eluting stent was angiographically noninferior in comparison with a last-generation biolimus-eluting stent., (© 2015 John Wiley & Sons Ltd.)
- Published
- 2015
- Full Text
- View/download PDF