1. Updated Meta-Analysis of Randomized Trials Comparing Safety and Efficacy of Intraoperative Defibrillation Testing with No Defibrillation Testing On Implantable Cardioverter-Defibrillator Implantation
- Author
-
Mariemma Paccanaro, Carlo Bonanno, Angelo Bruno Ramondo, Antonio Rossillo, and Antonio Raviele
- Subjects
inorganic chemicals ,medicine.medical_specialty ,lcsh:Diseases of the circulatory (Cardiovascular) system ,Defibrillation ,business.industry ,medicine.medical_treatment ,General Medicine ,Perioperative ,medicine.disease ,Ventricular tachycardia ,Implantable cardioverter-defibrillator ,Confidence interval ,law.invention ,Randomized controlled trial ,law ,lcsh:RC666-701 ,Relative risk ,Internal medicine ,Anesthesia ,Ventricular fibrillation ,medicine ,Cardiology ,business - Abstract
Introduction: There is an ongoing debate regarding the need to conduct intraoperative defibrillation testing (DFT) at the time of implantable cardioverter-defibrillator (ICD) implantation. To provide sufficiently strong evidence for the feasibility of omitting intraoperative DFT in clinical practice, we conducted a meta-analysis of randomized controlled trials (RCT) comparing patients with DFT and no-DFT.Methods: We systematically searched Medline (via PubMed), ClinicalTrial.gov, the Cochrane Central Register of Controlled Trials, and Embase for studies evaluating DFT vs. no-DFT on ICD implantation with regard to total mortality and arrhythmic death, efficacy of first and any appropriate shock in interrupting ventricular tachycardia (VT)/ventricular fibrillation (VF), and procedural adverse events. Effect estimates [risk ratio (RR) with 95% confidence intervals (CI)] were pooled using the random-effects model.Results: Our meta-analysis included 4 RCTs comprising 3770 patients (1896 with DFT and 1874 without DFT). Total mortality (RR = 1.00, 95% CI 0.86–1.17; P = 0.98) and arrhythmic death (RR = 1.60, 95% CI 0.46-5.59: P = 0.46) were not statistically different. Both first (RR = 0.94, 95% CI 0.89–0.98; P = 0.004) and any appropriate ICD shock (RR = 0.97, 95% CI 0.95–1.00; P = 0.02) significantly increased the rate of VT/VF interruption in the group with no-DFT in comparison with DFT. Finally, the incidence of adverse events was lower in no-DFT patients (RR = 1.23; 95% CI 1.00–1.51; P = 0.05).Conclusions: The practice of DFT (as opposed to no-DFT) did not yield benefits in mortality or the overall rate of conversion of VT/VT. Moreover, a slightly higher incidence of perioperative adverse events was observed in the DFT group.
- Published
- 2017