1. Determinants of image quality of rotational angiography for on-line assessment of frame geometry after transcatheter aortic valve implantation
- Author
-
Nahid El Faquir, Guenter Lauritsch, Peter de Jaegere, Zouhair Rahhab, Nicolas M. Van Mieghem, Carl Schultz, Anne-Marie Maugenest, Ramón Rodríguez-Olivares, and Cardiology
- Subjects
Male ,Aortic valve ,Cardiac Catheterization ,Rotational angiography ,Image quality ,medicine.medical_treatment ,Geometry ,030204 cardiovascular system & hematology ,Body Mass Index ,0302 clinical medicine ,Odds Ratio ,Medicine ,Prospective Studies ,030212 general & internal medicine ,Cardiac imaging ,Cardiac catheterization ,Aged, 80 and over ,Heart Valve Prosthesis Implantation ,medicine.diagnostic_test ,Angiography ,Treatment Outcome ,medicine.anatomical_structure ,Radiology Nuclear Medicine and imaging ,Aortic Valve ,Heart Valve Prosthesis ,Aortic valve stenosis ,Cardiology ,Female ,Radiology ,Artifacts ,Cardiology and Cardiovascular Medicine ,Agatston score ,medicine.medical_specialty ,Prosthesis Design ,03 medical and health sciences ,Imaging, Three-Dimensional ,Predictive Value of Tests ,Internal medicine ,Image Interpretation, Computer-Assisted ,Humans ,Radiology, Nuclear Medicine and imaging ,Aged ,Original Paper ,Transcatheter aortic valve implantation ,business.industry ,Aortic stenosis ,Reproducibility of Results ,Aortic Valve Stenosis ,medicine.disease ,Logistic Models ,Multivariate Analysis ,business ,Software - Abstract
To study the determinants of image quality of rotational angiography using dedicated research prototype software for motion compensation without rapid ventricular pacing after the implantation of four commercially available catheter-based valves. Prospective observational study including 179 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with either the Medtronic CoreValve (MCS), Edward-SAPIEN Valve (ESV), Boston Sadra Lotus (BSL) or Saint-Jude Portico Valve (SJP) in whom rotational angiography (R-angio) with motion compensation 3D image reconstruction was performed. Image quality was evaluated from grade 1 (excellent image quality) to grade 5 (strongly degraded). Distinction was made between good (grades 1, 2) and poor image quality (grades 3-5). Clinical (gender, body mass index, Agatston score, heart rate and rhythm, artifacts), procedural (valve type) and technical variables (isocentricity) were related with the image quality assessment. Image quality was good in 128 (72 %) and poor in 51 (28 %) patients. By univariable analysis only valve type (BSL) and the presence of an artefact negatively affected image quality. By multivariate analysis (in which BMI was forced into the model) BSL valve (Odds 3.5, 95 % CI [1.3-9.6], p = 0.02), presence of an artifact (Odds 2.5, 95 % CI [1.2-5.4], p = 0.02) and BMI (Odds 1.1, 95 % CI [1.0-1.2], p = 0.04) were independent predictors of poor image quality. Rotational angiography with motion compensation 3D image reconstruction using a dedicated research prototype software offers good image quality for the evaluation of frame geometry after TAVI in the majority of patients. Valve type, presence of artifacts and higher BMI negatively affect image quality.
- Published
- 2016