59 results on '"Beiert T"'
Search Results
2. Incidence of sustained ventricular tachyarrhythmias in patients with non-ischemic cardiomyopathy in a multicenter multinational WCD cohort
- Author
-
Erath, J W, primary, Koepsel, K K, additional, Kovacs, B K, additional, Dreher, T D, additional, Blockhaus, C B, additional, Grotzmann, M G, additional, Klein, N K, additional, Hijazi, M H, additional, Saguner, A S, additional, Kowitz, J K, additional, Duru, F D, additional, Beiert, T B, additional, Aweimer, A A, additional, Akin, I A, additional, and El-Battrawy, I B, additional
- Published
- 2023
- Full Text
- View/download PDF
3. Wearable cardioverter defibrillator after ICD-system explantation: data from a multicenter registry
- Author
-
El-Battrawy, I, primary, Beiert, T, additional, Koepsel, K, additional, Kovacs, B, additional, Blockhaus, C, additional, Klein, N, additional, Kuntz, T, additional, Shin, D I, additional, Abumayyaleh, M, additional, Saguner, A M, additional, Erath, J W, additional, Duru, F, additional, Muegge, A, additional, Akin, I, additional, and Aweimer, A, additional
- Published
- 2023
- Full Text
- View/download PDF
4. The use of wearable cardioverter defibrillator among patients suffering from myocarditis: data from a multicenter registry
- Author
-
El-Battrawy, I, primary, Koepsel, K, additional, Kovacs, B, additional, Blockhaus, C, additional, Gotzmann, M, additional, Klein, N, additional, Shin, D I, additional, Abumayyaleh, M, additional, Saguner, A M, additional, Erath, J W, additional, Duru, F, additional, Muegge, A, additional, Aweimer, A, additional, Akin, I, additional, and Beiert, T, additional
- Published
- 2023
- Full Text
- View/download PDF
5. TLR4 pathway induces proarrhythmogenic slow conduction by impaired depolarisation
- Author
-
Funken, M, primary, Knappe, V, additional, Beiert, T, additional, Nickenig, G, additional, Sasse, P, additional, and Schrickel, J W, additional
- Published
- 2022
- Full Text
- View/download PDF
6. P1595Increased in vivo perpetuation of whole-heart ventricular arrhythmia in heterozygous Na+/Ca2+-exchanger knockout mice
- Author
-
Boegeholz, N, primary, Knappe, V, additional, Pauls, P, additional, Nickenig, G, additional, Eckardt, L, additional, Schrickel, J W, additional, and Beiert, T B, additional
- Published
- 2019
- Full Text
- View/download PDF
7. P.79Malignant cardiac phenotype after pressure overload in autosomal-dominant desminopathies: Lessons from heterozygous R349P desmin knock-in mice
- Author
-
Stöckigt, F., primary, Eichhorn, L., additional, Beiert, T., additional, Knappe, V., additional, Radecke, T., additional, Steinmetz, M., additional, Berwanger, C., additional, Nickenig, G., additional, Peeva, V., additional, Kunz, W., additional, Clemen, C., additional, Schröder, R., additional, and Schrickel, J., additional
- Published
- 2019
- Full Text
- View/download PDF
8. Maligner kardialer Phänotyp durch induzierte Widerstandsdruckerhöhung in autosomal-dominanten Desminopathien
- Author
-
Stöckigt, F, additional, Eichhorn, L, additional, Beiert, T, additional, Knappe, V, additional, Radecke, T, additional, Steinmetz, M, additional, Berwanger, C, additional, Nickenig, G, additional, Peeva, V, additional, Kunz, W, additional, Clemen, CS, additional, Schröder, R, additional, and Schrickel, JW, additional
- Published
- 2019
- Full Text
- View/download PDF
9. P5222Cardiac magnetic resonance using late gadolinium enhancement imaging and T1 mapping predicts poor outcome in patients with atrial fibrillation after catheter ablation therapy
- Author
-
Luetkens, J., primary, Wolpers, C., additional, Beiert, T., additional, Meendermann, H., additional, Daye, N., additional, Knappe, V., additional, Stoeckigt, F., additional, Karsdal, M., additional, Nielsen, S., additional, Genovese, F., additional, Dabir, D., additional, Linhart, M., additional, Nickenig, G., additional, Schrickel, J., additional, and Andrie, R., additional
- Published
- 2017
- Full Text
- View/download PDF
10. P5837Optogenetic cardioversion terminates atrial fibrillation in wild-type mice after gene transfer
- Author
-
Beiert, T., primary, Bruegmann, T., additional, Vogt, C., additional, Nickenig, G., additional, Schrickel, J.W., additional, and Sasse, P., additional
- Published
- 2017
- Full Text
- View/download PDF
11. P5387Relaxin reduces cardiac inflammation and fibrosis and prevents post-infarction arrhythmia in cryoinfarcted mice
- Author
-
Beiert, T., primary, Knappe, V., additional, Tiyerili, V., additional, Stoeckigt, F., additional, Effelsberg, V., additional, Linhart, M., additional, Roell, W., additional, Nickenig, G., additional, Schrickel, J.W., additional, and Andrie, R.P., additional
- Published
- 2017
- Full Text
- View/download PDF
12. Channelrhodopsin2 expression in cardiomyocytes: A new tool for light-induced depolarization with high spatio-temporal resolution in vitro and in vivo
- Author
-
Bruegmann, T, primary, Malan, D, additional, Hesse, M, additional, Beiert, T, additional, Fuegemann, CJ, additional, Fleischmann, BK, additional, and Sasse, P, additional
- Published
- 2011
- Full Text
- View/download PDF
13. Maligner kardialer Phänotyp durch induzierte Widerstandsdruckerhöhung in autosomal-dominanten Desminopathien
- Author
-
Stöckigt, F, Eichhorn, L, Beiert, T, Knappe, V, Radecke, T, Steinmetz, M, Berwanger, C, Nickenig, G, Peeva, V, Kunz, W, Clemen, CS, Schröder, R, and Schrickel, JW
- Published
- 2019
- Full Text
- View/download PDF
14. Predictors of ventricular tachyarrhythmia in patients with a wearable cardioverter defibrillator: an international multicenter registry.
- Author
-
Kreimer F, Koepsel K, Gotzmann M, Kovacs B, Dreher TC, Blockhaus C, Klein N, Kuntz T, Shin DI, Lapp H, Rosenkaimer S, Abumayyaleh M, Hamdani N, Saguner AM, Erath JW, Duru F, Beiert T, Schiedat F, Weth C, Custodis F, Akin I, Mügge A, Aweimer A, and El-Battrawy I
- Subjects
- Humans, Male, Female, Middle Aged, Aged, Europe, Defibrillators, Ventricular Fibrillation therapy, Risk Assessment, Defibrillators, Implantable, Treatment Outcome, Risk Factors, Tachycardia, Ventricular therapy, Registries, Wearable Electronic Devices, Death, Sudden, Cardiac prevention & control
- Abstract
Background and Aims: Wearable cardioverter defibrillator (WCD) can protect patients from sudden cardiac death due to ventricular tachyarrhythmias and serve as a bridge to decision of definite defibrillator implantation. The aim of this analysis from an international, multicenter WCD registry was to identify predictors of sustained ventricular tachycardia (VT) and/or ventricular fibrillation (VF) in this population., Methods: One thousand six hundred seventy-five patients with WCD were included in a multicenter registry from 9 European centers, with a median follow-up of 440 days (IQR 120-893). The primary study end point was the occurrence of sustained VT/VF., Results: Sustained VT was detected by WCD in 5.4% and VF in 0.9% of all patients. Of the 30.3% of patients receiving ICD implantation during follow-up, sustained VT was recorded in 9.3% and VF in 2.6%. Non-ischemic cardiomyopathy (HR 0.5, p < 0.001), and medication with angiotensin-converting enzyme inhibitors (HR 0.7, p = 0.027) and aldosterone antagonists (HR 0.7, p = 0.005) were associated with a significantly lower risk of VT/VF., Conclusions: Patients who received WCD due to a transient increased risk of sudden cardiac death have a comparatively lower risk of VT/VF in the presence of non-ischemic cardiomyopathy. Of note, optimal medical treatment for heart failure not only results in an improvement in left ventricular ejection fraction but also in a reduction in the risk for VT/VF., Competing Interests: Declarations. Competing interests: The authors declare no competing interests., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
15. Association of BMI with adherence and outcome in heart failure patients treated with wearable cardioverter defibrillator.
- Author
-
Abumayyaleh M, Koepsel K, Erath JW, Kuntz T, Klein N, Kovacs B, Duru F, Saguner AM, Blockhaus C, Shin DI, Kreimer F, Gotzmann M, Lapp H, Beiert T, Aweimer A, Mügge A, Weiß C, El-Battrawy I, and Akin I
- Abstract
Background: Obesity is a known risk factor for cardiovascular disease (CVD), yet an 'obesity paradox' has been observed in various CVD contexts. The impact of obesity on heart failure (HF) patients treated with a wearable cardioverter-defibrillator (WCD) remains underexplored., Methods: In a multicentre international registry, we retrospectively collected data from a consecutive series of 1003 patients. These patients were divided into three body mass index (BMI) groups: <25 kg/m
2 (n = 348), 25-30 kg/m2 (n = 383), and >30 kg/m2 (n = 272), with BMI > 30 kg/m2 defined as the reference category. Demographics, indications, adherence, WCD shocks, arrhythmic events, rehospitalization due to cardiovascular causes, and mortality were analysed., Results: At 3 month follow-up, patients with a BMI > 30 showed the greatest improvement in left ventricular ejection fraction (LVEF) at 51.4%, significantly higher than the 41.4% in those with a BMI < 25 (P = 0.017) and comparable with the 49.4% in the BMI 25-30 group (P = 0.635). WCD wearing time and adherence were similar across all BMI groups. The incidence of WCD shock was similar across BMI groups. Rates of ventricular tachycardia (VT), ventricular fibrillation and non-sustained VT (ns-VT) were comparable across BMI groups. The rate of implantable cardioverter-defibrillator (ICD) implantation was 40.3% across all patients, with a slightly lower rate in the BMI > 30 group (36.8%) compared with others, although not significantly. Rehospitalization due to cardiovascular causes was significantly lower in the BMI > 30 group (55.4%) compared with the BMI 25-30 group (70.9%; P = 0.048), but similar to the BMI < 25 group (54.9%; P = 0.957). At 2 year follow-up, mortality was lower in the BMI > 30 group (5.9%) compared with the BMI < 25 (7.5%; P = 0.029) and BMI 25-30 groups (7%; P = 0.681). In multivariable analysis, LVEF at long term was significantly associated with a reduction in mortality., Conclusions: Obese patients exhibited significantly greater improvement in LVEF, which was associated with reduced mortality. Adherence to WCD therapy was excellent across all BMI groups. ICD implantation occurred in 40.3% of patients, with similar WCD shock rates and arrhythmic events across BMI groups. An obesity paradox was observed, with obese patients demonstrating significantly lower rehospitalization rates due to cardiovascular causes and reduced mortality at follow-up., (© 2024 The Author(s). ESC Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.)- Published
- 2024
- Full Text
- View/download PDF
16. Microbial growth on temporary pacemaker leads post-TAVR: pathogen spectrum and clinical implications.
- Author
-
Mousa Basha M, Al-Kassou B, Gestrich C, Weber M, Beiert T, Bakhtiary F, Nickenig G, Zimmer S, and Shamekhi J
- Abstract
Background and Objective: Transcatheter aortic valve replacement (TAVR) is an established treatment option for patients with symptomatic severe aortic stenosis across all stages of surgical risk. Rapid pacing during the procedure and the risk for the occurrence of conduction disturbances after TAVR requires the pre-interventional insertion of a temporary pacemaker (TP). However, this approach poses risks, including the risk of infection. For this reason, the following study aimed to investigate microbial growth on temporary pacemaker leads and its association with outcome post-TAVR and to identify associated pathogens and related risk factors., Methods: A prospective study was conducted including 344 patients undergoing TAVR at the Heart Centre Bonn. Of these, 97 patients did not require TP leads as they already had permanent pacemakers; this group was considered as comparison group. The TP leads of the remaining 247 patients were removed, sonicated, and cultured to investigate bacterial growth over a period of 14 days. Finally, we compared patients without microbial growth (n = 184) and patients with microbial growth (n = 63). The primary endpoint of the study was 30-day all-cause mortality, secondary endpoints were periprocedural infections, the length of the postprocedural hospital stay, 30-day major vascular complications and the 30-day stroke rate., Results: The majority of cases (74.5%) showed no bacterial growth. In the remaining cases (25.5%), diverse microorganisms were identified, mostly non-pathogenic bacteria. The statistical analysis revealed no significant differences between groups according to microbial growth in terms of 30-day mortality (p = 0.446), postprocedural hospital stay (p = 0.401), periprocedural infections (p = 0.434), 30-day major vascular complications (p = 1.0), and 30-day stroke rate (p = 1.0). Notably, the timing of sheath insertion was significantly associated with microbial growth; sheath placement more than 2 days prior to the procedure was associated with a significantly higher risk of microbial growth (OR: 2.1; 95% CI 1.1-4.3) (p = 0.030)., Conclusions: The presence of temporary leads does not significantly impact clinical outcomes, irrespective of bacterial growth on the lead. However, the timing and duration of sheath placement plays a crucial role in contamination incidence. Thus, temporary leads/sheaths should be placed shortly before the procedure and removed promptly to reduce the risk of contamination/infection., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
17. Impact of gender in patients with device-related thrombosis after left atrial appendage closure - A sub-analysis from the multicenter EUROC-DRT-registry.
- Author
-
Saw J, Vij V, Galea R, Piayda K, Nelles D, Vogt L, Gloekler S, Fürholz M, Meier B, Räber L, O'Hara G, Arzamendi D, Agudelo V, Asmarats L, Freixa X, Flores-Umanzor E, De Backer O, Sondergaard L, Nombela-Franco L, Salinas P, Korsholm K, Nielsen-Kudsk JE, Zeus T, Operhalski F, Schmidt B, Montalescot G, Guedeney P, Iriart X, Miton N, Gilhofer T, Fauchier L, Veliqi E, Meincke F, Petri N, Nordbeck P, Gonzalez-Ferreiro R, Cruz-González I, Bhatt DL, Laricchia A, Mangieri A, Omran H, Schrickel JW, Beiert T, Rodes-Cabau J, Nickenig G, Sievert H, Sedaghat A, and Afzal S
- Subjects
- Humans, Female, Male, Aged, Sex Factors, Anticoagulants therapeutic use, Risk Factors, Postoperative Complications, Septal Occluder Device, Treatment Outcome, Echocardiography, Transesophageal methods, Europe epidemiology, Left Atrial Appendage Closure, Atrial Appendage surgery, Registries, Thrombosis etiology, Atrial Fibrillation surgery
- Abstract
Background: Device-related thrombosis (DRT) is a common finding after left atrial appendage closure (LAAC) and is associated with worse outcomes. As women are underrepresented in clinical studies, further understanding of sex differences in DRT patients is warranted., Methods and Results: This sub-analysis from the EUROC-DRT-registry compromises 176 patients with diagnosis of DRT after LAAC. Women, who accounted for 34.7% (61/176) of patients, were older (78.0 ± 6.7 vs. 74.9 ± 9.1 years, p = .06) with lower rates of comorbidities. While DRT was detected significantly later in women (173 ± 267 vs. 127 ± 192 days, p = .01), anticoagulation therapy was escalated similarly, mainly with initiation of novel oral anticoagulant (NOAC), vitamin K antagonist (VKA) or heparin. DRT resolution was achieved in 67.5% (27/40) of women and in 75.0% (54/72) of men (p = .40). In the remaining cases, an intensification/switch of anticoagulation was conducted in 50.% (9/18) of men and in 41.7% (5/12) of women. Final resolution was achieved in 72.5% (29/40) cases in women, and in 81.9% (59/72) cases in men (p = .24). Women were followed-up for a similar time as men (779 ± 520 vs. 908 ± 687 days, p = .51). Kaplan-Meier analysis revealed no difference in mortality rates in women (Hazard Ratio [HR]: 1.73, 95%-Confidence interval [95%-CI]: .68-4.37, p = .25) and no differences in stroke (HR: .83, 95%-CI: .30-2.32, p = .72) within 2 years after LAAC., Conclusion: Evaluation of risk factors and outcome revealed no differences between men and women, with DRT in women being diagnosed significantly later. Women should be monitored closely to assess for DRT formation/resolution. Treatment strategies appear to be equally effective., (© 2024 The Author(s). Echocardiography published by Wiley Periodicals LLC.)
- Published
- 2024
- Full Text
- View/download PDF
18. Prevention of cerebral thromboembolism by oral anticoagulation with dabigatran after pulmonary vein isolation for atrial fibrillation: the ODIn-AF trial.
- Author
-
Schrickel JW, Beiert T, Linhart M, Luetkens JA, Schmitz J, Schmid M, Hindricks G, Arentz T, Stellbrink C, Deneke T, Bogossian H, Sause A, Steven D, Gonska BD, Rudic B, Lewalter T, Zabel M, Geisler T, Schumacher B, Jung W, Kleemann T, Luik A, Veltmann C, Coenen M, and Nickenig G
- Subjects
- Humans, Male, Female, Prospective Studies, Middle Aged, Administration, Oral, Aged, Treatment Outcome, Intracranial Embolism prevention & control, Intracranial Embolism etiology, Intracranial Embolism epidemiology, Antithrombins administration & dosage, Antithrombins adverse effects, Incidence, Follow-Up Studies, Time Factors, Anticoagulants administration & dosage, Anticoagulants adverse effects, Atrial Fibrillation complications, Atrial Fibrillation diagnosis, Atrial Fibrillation surgery, Dabigatran administration & dosage, Dabigatran adverse effects, Pulmonary Veins surgery, Catheter Ablation methods, Catheter Ablation adverse effects
- Abstract
Background and Objectives: Long-term oral anticoagulation (OAC) following successful catheter ablation of atrial fibrillation (AF) remains controversial. Prospective data are missing. The ODIn-AF study aimed to evaluate the effect of OAC on the incidence of silent cerebral embolic events and clinically relevant cardioembolic events in patients at intermediate to high risk for embolic events, free from AF after pulmonary vein isolation (PVI)., Methods: This prospective, randomized, multicenter, open-label, blinded endpoint interventional trial enrolled patients who were scheduled for PVI to treat paroxysmal or persistent AF. Six months after PVI, AF-free patients were randomized to receive either continued OAC with dabigatran or no OAC. The primary endpoint was the incidence of new silent micro- and macro-embolic lesions detected on brain MRI at 12 months of follow-up compared to baseline. Safety analysis included bleedings, clinically evident cardioembolic, and serious adverse events (SAE)., Results: Between 2015 and 2021, 200 patients were randomized into 2 study arms (on OAC: n = 99, off OAC: n = 101). There was no significant difference in the occurrence of new cerebral microlesions between the on OAC and off OAC arm [2 (2%) versus 0 (0%); P = 0.1517] after 12 months. MRI showed no new macro-embolic lesion, no clinical apparent strokes were present in both groups. SAE were more frequent in the OAC arm [on OAC n = 34 (31.8%), off OAC n = 18 (19.4%); P = 0.0460]; bleedings did not differ., Conclusion: Discontinuation of OAC after successful PVI was not found to be associated with an elevated risk of cerebral embolic events compared with continued OAC after a follow-up of 12 months., (© 2023. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
19. No beneficial use of the wearable cardioverter defibrillator among patients suffering from inherited and congenital heart disease: data from a European multicenter registry.
- Author
-
Koepsel K, Dreher TC, Blockhaus C, Gotzmann M, Klein N, Kuntz T, Shin DI, Lapp H, Schiedat F, Abumayyaleh M, Beiert T, Weth C, Kovacs B, Rosenkaimer S, Kowitz J, Saguner AM, Erath JW, Duru F, Mügge A, Akin I, Aweimer A, Hamdani N, and El-Battrawy I
- Abstract
Background: Data on the use of the wearable cardioverter defibrillator in patients suffering from inherited and congenital heart disease are limited. Consequently, evidence for guideline recommendations in this patient population is lacking., Methods: In total 1,675 patients were included in a multicenter registry of eight European centers. In the present cohort, we included 18 patients suffering from congenital and inherited heart disease., Results: Nine patients (50%) were male with a mean age of 41.3 ± 16.4 years. Four patients suffered from hypertrophic cardiomyopathy (HCM), four patients suffered from non-compaction cardiomyopathy (NCCM), two patients were diagnosed with arrhythmogenic right ventricular cardiomyopathy (ARVC) and one patient suffered from muscular dystrophy of the limb-girdle type with cardiac involvement, secondary cardiomyopathy. Three patients presented with Brugada syndrome (BrS). One patient suffered from long-QT syndrome type 1 (LQTS1). Furthermore, two patients had congenital heart defects and one patient suffered from cardiac sarcoidosis (CS). There were no appropriate/inappropriate shocks with the WCD in this cohort. One patient had recurrent self-limiting sustained ventricular tachycardia during the wear time, but actively inhibited a shock and was hospitalized. The compliance rate in this cohort was 77.8% with a mean wear time of 45.3 ± 26.9 days with a mean follow-up time of 570 ± 734 days. 55.6% (10/18) of the patients received an ICD after WCD wear time., Conclusions: This retrospective study of patients with inherited and congenital heart disease shows that WCD use is not beneficial in the majority of patients with inherited and congenital heart disease., Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest. The author(s) declared that they were not an editorial board member of Frontiers, at the time of submission. AS received educational grants through his institution from Abbott, Bayer Healthcare, Biosense Webster, Biotronik, Boston Scientific, BMS/Pfizer, and Medtronic; and speaker/advisory board/consulting fees from Bayer Healthcare, Biotronik, Daiichi-Sankyo, Medtronic, Novartis, Pfizer, Stride Bio Inc. and Zoll., (© 2024 Koepsel, Dreher, Blockhaus, Gotzmann, Klein, Kuntz, Shin, Lapp, Schiedat, Abumayyaleh, Beiert, Weth, Kovacs, Rosenkaimer, Kowitz, Saguner, Erath, Duru, Mügge, Akin, Aweimer, Hamdani and El-Battrawy.)
- Published
- 2024
- Full Text
- View/download PDF
20. Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study.
- Author
-
Ekanem E, Neuzil P, Reichlin T, Kautzner J, van der Voort P, Jais P, Chierchia GB, Bulava A, Blaauw Y, Skala T, Fiala M, Duytschaever M, Szeplaki G, Schmidt B, Massoullie G, Neven K, Thomas O, Vijgen J, Gandjbakhch E, Scherr D, Johannessen A, Keane D, Boveda S, Maury P, García-Bolao I, Anic A, Hansen PS, Raczka F, Lepillier A, Guyomar Y, Gupta D, Van Opstal J, Defaye P, Sticherling C, Sommer P, Kucera P, Osca J, Tabrizi F, Roux A, Gramlich M, Bianchi S, Adragão P, Solimene F, Tondo C, Russo AD, Schreieck J, Luik A, Rana O, Frommeyer G, Anselme F, Kreis I, Rosso R, Metzner A, Geller L, Baldinger SH, Ferrero A, Willems S, Goette A, Mellor G, Mathew S, Szumowski L, Tilz R, Iacopino S, Jacobsen PK, George A, Osmancik P, Spitzer S, Balasubramaniam R, Parwani AS, Deneke T, Glowniak A, Rossillo A, Pürerfellner H, Duncker D, Reil P, Arentz T, Steven D, Olalla JJ, de Jong JSSG, Wakili R, Abbey S, Timo G, Asso A, Wong T, Pierre B, Ewertsen NC, Bergau L, Lozano-Granero C, Rivero M, Breitenstein A, Inkovaara J, Fareh S, Latcu DG, Linz D, Müller P, Ramos-Maqueda J, Beiert T, Themistoclakis S, Meininghaus DG, Stix G, Tzeis S, Baran J, Almroth H, Munoz DR, de Sousa J, Efremidis M, Balsam P, Petru J, Küffer T, Peichl P, Dekker L, Della Rocca DG, Moravec O, Funasako M, Knecht S, Jauvert G, Chun J, Eschalier R, Füting A, Zhao A, Koopman P, Laredo M, Manninger M, Hansen J, O'Hare D, Rollin A, Jurisic Z, Fink T, Chaumont C, Rillig A, Gunawerdene M, Martin C, Kirstein B, Nentwich K, Lehrmann H, Sultan A, Bohnen J, Turagam MK, and Reddy VY
- Subjects
- Humans, Female, Male, Middle Aged, Aged, Treatment Outcome, Postoperative Complications epidemiology, Postoperative Complications etiology, Atrial Fibrillation surgery, Atrial Fibrillation therapy, Catheter Ablation adverse effects, Catheter Ablation methods
- Abstract
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
21. Contrast-free left atrial appendage occlusion in patients using the LAMBRE™ device.
- Author
-
Vij V, Ruf TF, Thambo JB, Vogt L, Al-Sabri SMA, Nelles D, Schrickel JW, Beiert T, Nickenig G, von Bardeleben RS, Iriart X, and Sedaghat A
- Subjects
- Humans, Male, Female, Aged, Retrospective Studies, Aged, 80 and over, Registries, Treatment Outcome, Echocardiography, Transesophageal methods, Contrast Media administration & dosage, Follow-Up Studies, Atrial Appendage surgery, Atrial Appendage diagnostic imaging, Atrial Fibrillation surgery, Atrial Fibrillation diagnostic imaging, Septal Occluder Device
- Abstract
Background: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device., Methods: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed., Results: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5 minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm
2 . Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118)., Conclusion: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC., (Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.)- Published
- 2024
- Full Text
- View/download PDF
22. Loss of ceramide synthase 5 inhibits the development of experimentally induced aortic valve stenosis.
- Author
-
Reese L, Niepmann ST, Düsing P, Hänschke L, Beiert T, Zimmer S, Nickenig G, Bauer R, Jansen F, and Zietzer A
- Abstract
Aim: Inflammation and calcification are hallmarks in the development of aortic valve stenosis (AVS). Ceramides mediate inflammation and calcification in the vascular tissue. The highly abundant d18:1,16:0 ceramide (C16) has been linked to increased cardiovascular mortality and obesity. In this study, we investigate the role of ceramide synthase 5 (CerS5), a critical enzyme for C16 ceramide synthesis, in the development of AVS, particularly in conjunction with a high-fat/high-cholesterol diet (Western diet, WD)., Methods: We used wild-type (WT) and CerS5
-/- mice on WD or normal chow in a wire injury model. We measured the peak velocity to determine AVS development and performed histological analysis of the aortic valve area, immune cell infiltration (CD68 staining), and calcification (von Kossa). In vitro experiments involved measuring the calcification of human aortic valvular interstitial cells (VICs) and evaluating cytokine release from THP-1 cells, a human leukemia monocytic-like cell line, following CerS5 knockdown., Results: CerS5-/- mice showed a reduced peak velocity compared to WT only in the experiment with WD. Likewise, we observed reduced immune cell infiltration and calcification in the aortic valve of CerS5-/- mice, but only on WD. In vitro, calcification was reduced after knockdown of CerS5 in VICs, while THP-1 cells exhibited a decreased inflammatory response following CerS5 knockdown., Conclusion: We conclude that CerS5 is an important mediator for the development of AVS in mice on WD and regulates critical pathophysiological hallmarks of AVS formation. CerS5 is therefore an interesting target for pharmacological therapy and merits further investigation., (© 2024 The Authors. Acta Physiologica published by John Wiley & Sons Ltd on behalf of Scandinavian Physiological Society.)- Published
- 2024
- Full Text
- View/download PDF
23. Comparison of Arctic Front Advance Pro and POLARx cryoballoons for ablation therapy of atrial fibrillation: an intraprocedural analysis.
- Author
-
Knappe V, Lahrmann C, Funken M, Zietzer A, Gestrich C, Nickenig G, Schrickel JW, and Beiert T
- Abstract
Introduction: Cryoballoon (CB) ablation has become a popular method for pulmonary vein isolation (PVI) in atrial fibrillation (AF) treatment. This study aimed to compare the intraprocedural ablation characteristics of two cryoballoons, Arctic Front Advance Pro™ (AFA-Pro, Medtronic) and POLARx™ (Boston Scientific)., Methods and Results: In this retrospective single-center study, 230 symptomatic paroxysmal or persistent AF patients underwent CB ablation with either AFA-Pro or POLARx. Propensity-score matching resulted in two cohorts of 114 patients each. Baseline and procedural characteristics were comparable between both CBs. POLARx achieved lower minimal temperatures (e.g., left superior pulmonary vein, LSPV: AFA-Pro - 49.0 °C vs. POLARx - 59.5 °C) and lower temperatures at time-to-isolation (TTI). Additionally, POLARx reached lower temperatures faster, as evidenced by lower temperatures after 40 and 60 s, and a larger mean temperature change between 20 and 40 s. POLARx also had a greater area under the curve below 0 °C and a longer thawing phase. Both CBs achieved comparable high rates of final PV-isolation. TTI, minimal esophagus temperature, and first-pass isolation rates were similar between groups. Periprocedural complications, including phrenic nerve injuries, were comparable. Troponin levels in the left atrium were elevated with both systems. Values and change in troponin were numerically higher in the POLARx group (delta troponin: AFA-Pro 36.3 (26.4, 125.4) ng/L vs. POLARx 104.9 (49.5, 122.2) ng/L), p = 0.077)., Conclusion: AFA-Pro and POLARx are both highly effective and safe CB systems for PVI. POLARx exhibited significant faster and lower freezing characteristics, and numerically higher troponin levels might indicate greater myocardial injury. However, these differences did not translate into improved performance, procedural efficiency, or safety., (© 2024. The Author(s).)
- Published
- 2024
- Full Text
- View/download PDF
24. The CT derived angle between the transseptal puncture site and the left atrial appendage as a predictor for complex interventional occlusion procedures.
- Author
-
Nelles D, Amli H, Sugiura A, Vij V, Beiert T, Nickenig G, Kütting D, Schrickel JW, and Sedaghat A
- Subjects
- Humans, Treatment Outcome, Echocardiography, Transesophageal methods, Retrospective Studies, Cardiac Catheterization methods, Tomography, Tomography, X-Ray Computed, Atrial Appendage diagnostic imaging, Atrial Appendage surgery, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation surgery
- Abstract
Objective: To evaluate the role of the CT-derived angle between the intra-atrial septum (IAS) and the left atrial appendage (LAA) on procedural complexity and clinical outcomes in left atrial appendage occlusion (LAAO) procedures., Background: Given the broad variations in anatomy, LAAO remains one of the most challenging interventional procedures in structural heart disease. In recent years, preprocedural cardiac tomography (CT) has evolved as a valuable tool; however, prediction of procedural complexity remains cumbersome., Methods: We retrospectively analyzed 47 patients that underwent LAAO at our center in whom pre-procedural cardiac CT-scans were available. Among other baseline parameters, we measured the angle between the LAA ostium and the preferred transseptal puncture site at the IAS. We compared patients with an angle above and below the median regarding procedural characteristics and procedural outcome., Results: The median angle between the LAA and the IAS was 127.3° (IQR: 120.9-141.3). LAAO took longer in patients with a measured angle below the median (55.0 ± 22.7 min vs. 41.3 ± 17.5 min; p = .04), resulting in longer radiation times (13.0 ± 5.3 min vs. 9.8 ± 5.7 min; p = .04) and more contrast use (61.1 ± 47.5 mL vs. 33.6 ± 24.7 mL; p = .05). Moreover, the necessity for a sheath exchange was significantly higher (30.4% vs. 4.2%, p = .02) and device repositioning or device resizing trended to be more frequent (26.1% vs. 8.3%; p = .1 and 21.7% vs. 8.3%; p = .2). There were no differences in procedural outcome, device-position and peri-device leak (PDL)., Conclusions: The angle between the transseptal puncture site and the LAA ostium may serve as a predictor for more demanding LAAO interventions. In our study a steeper angle led to a prolonged procedure resulting in higher doses of contrast and radiation, but was not associated with a worse procedural outcome., (© 2023 The Authors. Echocardiography published by Wiley Periodicals LLC.)
- Published
- 2023
- Full Text
- View/download PDF
25. Cardiac autonomic dysfunction in adult congenital heart disease.
- Author
-
Pizarro C, Bosse FL, Begrich C, Reznakova B, Beiert T, Schrickel JW, Nickenig G, Skowasch D, and Momcilovic D
- Subjects
- Humans, Adult, Female, Male, Heart, Autonomic Nervous System, Electrocardiography, Ambulatory, Death, Sudden, Cardiac, Heart Rate physiology, Heart Defects, Congenital complications, Heart Defects, Congenital diagnosis, Autonomic Nervous System Diseases
- Abstract
Purpose: Due to recent advances in diagnosis and treatment, the number of adults with congenital heart disease (ACHD) has substantially increased. This achievement is mitigated by rhythm disorders. Here, we sought to determine alterations in heart rate variability (HRV) and their prognostic value in ACHD., Methods: Ninety seven ACHD patients (39.2 ± 14.1 years, 51.5% female) and 19 controls (39.7 ± 15.0 years, 47.4% female) underwent 24-h Holter monitoring., Results: As compared to controls, ACHD patients offered a significantly higher burden of premature ventricular contractions (p = 0.02) and decreased HRV indices (natural logarithmic transformation of very low frequency (lnVLF): 7.46 ± 0.76 ms
2 vs. 7.91 ± 0.92ms2 , p = 0.03; natural logarithmic transformation of low frequency (lnLF): 6.39 ± 0.95ms2 vs. 7.01 ± 1.07ms2 , p = 0.01; natural logarithmic transformation of the ratio of low to high frequency spectra (lnLF/HF): 0.81 ± 0.74 vs. 1.17 ± 0.51, p = 0.04). No differences in HRV measures were observed across ACHD lesion groups. NT-proBNP levels were significantly related to both time and frequency domain indices (natural logarithmic transformation of the standard deviation of NN intervals (lnSDNN): Spearman´s rho = -0.32, p = 0.001; natural logarithmic transformation of the standard deviation of the average NN intervals for each 5-min segment of a 24-h Holter monitoring (lnSDANN): Spearman´s rho: -0.33, p = 0.001; natural logarithmic transformation of the total power (lnTP): Spearman´s rho: -0.25, p = 0.01; lnVLF: Spearman´s rho: -0.33, p = 0.001; lnLF: Spearman´s rho: -0.35, p < 0.001; lnLF/HF: Spearman´s rho: -0.34, p = 0.001). After a mean follow-up of 3.9 ± 0.7 years, 8 patients died and 3 patients survived sudden cardiac death (SCD). Several HRV parameters were significantly higher in event-free ACHD patients than in those who died or survived SCD (natural logarithmic transformation of the average of the standard deviations of NN intervals for each 5-min segment of a 24-h Holter monitoring (lnASDNN): p = 0.04; lnPNN30: p = 0.04; lnVFL: p = 0.03; lnLF: p < 0.01). On univariate Cox regression analysis, the time domain indices lnSDNN, lnASDNN and lnPNN30, as well as the frequency domain parameters lnTP, lnVLF and lnLF were associated with death and survived cardiac arrest., Conclusion: ACHD is accompanied by HRV impairment that carries prognostic implications on ACHD mortality and survived SCD., (© 2023. BioMed Central Ltd., part of Springer Nature.)- Published
- 2023
- Full Text
- View/download PDF
26. Use of the Wearable Cardioverter-Defibrillator Among Patients With Myocarditis and Reduced Ejection Fraction or Ventricular Tachyarrhythmia: Data From a Multicenter Registry.
- Author
-
El-Battrawy I, Koepsel K, Tenbrink D, Kovacs B, Dreher TC, Blockhaus C, Gotzmann M, Klein N, Kuntz T, Shin DI, Lapp H, Rosenkaimer S, Abumayyaleh M, Hamdani N, Saguner AM, Kowitz J, Erath JW, Duru F, Mügge A, Akin I, Aweimer A, and Beiert T
- Subjects
- Humans, Male, Adult, Middle Aged, Aged, Female, Stroke Volume, Ventricular Fibrillation diagnosis, Ventricular Fibrillation therapy, Ventricular Function, Left, Defibrillators, Myocarditis complications, Myocarditis therapy, Tachycardia, Ventricular diagnosis, Tachycardia, Ventricular therapy, Wearable Electronic Devices
- Abstract
Background Data on the use of the wearable cardioverter-defibrillator (WCD) among patients with myocarditis remain sparse. Consequently, evidence for guideline recommendations in this patient population is lacking. Methods and Results In total, 1596 consecutive patients were included in a multicenter registry from 8 European centers, with 124 patients (8%) having received the WCD due to myocarditis and reduced left ventricular ejection fraction or prior ventricular tachyarrhythmia. The mean age was 51.6±16.3 years, with 74% being male. Patients were discharged after index hospitalization on heart failure medication: Angiotensin-converting enzyme inhibitors (62.5%), angiotensin-receptor-neprilysin inhibitor (22.9%), aldosterone-antagonists (51%), or beta blockers (91.4%). The initial median left ventricular ejection fraction was 30% (22%-45%) and increased to 48% (39%-55%) over long-term follow-up ( P <0.001). The median BNP (brain natriuretic peptide) level at baseline was 1702 pg/mL (565-3748) and decreased to 188 pg/mL (26-348) over long-term follow-up ( P =0.022). The mean wear time was 79.7±52.1 days and 21.0±4.9 hours per day. Arrhythmic event rates documented by the WCD were 9.7% for nonsustained ventricular tachycardia, 6.5% for sustained ventricular tachycardia, and 0% for ventricular fibrillation. Subsequently, 2.4% of patients experienced an appropriate WCD shock. The rate of inappropriate WCD shocks was 0.8%. All 3 patients with appropriate WCD shock had experienced ventricular tachycardia/ventricular fibrillation before WCD prescription, with only 1 patient showing a left ventricular ejection fraction <35%. Conclusions Patients with myocarditis and risk for occurrence of ventricular tachyarrhythmia may benefit from WCD use. Prior ventricular arrhythmia might appear as a better risk predictor than a reduced left ventricular ejection fraction <35% in this population.
- Published
- 2023
- Full Text
- View/download PDF
27. Age differences of patients treated with wearable cardioverter defibrillator: Data from a multicentre registry.
- Author
-
El-Battrawy I, Tenbrink D, Kovacs B, Dreher TC, Blockhaus C, Klein N, Shin DI, Hijazi M, Rosenkaimer S, Beiert T, Abumayyaleh M, Saguner AM, Kowitz J, Erath JW, Duru F, Mügge A, Aweimer A, and Akin I
- Subjects
- Humans, Aged, Middle Aged, Stroke Volume, Ventricular Function, Left, Death, Sudden, Cardiac epidemiology, Death, Sudden, Cardiac prevention & control, Death, Sudden, Cardiac etiology, Registries, Defibrillators adverse effects, Retrospective Studies, Myocardial Ischemia therapy, Myocardial Ischemia complications, Atrial Fibrillation complications, Wearable Electronic Devices
- Abstract
Background: Wearable cardioverter defibrillators (WCD) are used as a 'bridging' technology in patients, who are temporarily at high risk for sudden cardiac death (SCD). Several factors should be taken into consideration, for example patient selection, compliance and optimal drug treatment, when WCD is prescribed. We aimed to present real-world data from seven centres from Germany and Switzerland according to age differences regarding the outcome, prognosis, WCD data and compliance., Materials and Methods: Between 04/2012 and 03/2021, 1105 patients were included in this registry. Outcome data according to age differences (old ≥45 years compared to young <45 years) were analysed. At young age, WCDs were more often prescribed due to congenital heart disease and myocarditis. On the other hand, ischaemic cardiomyopathy (ICM) was more present in older patients. Wear days of WCD were similar between both groups (p = .115). In addition, during the WCD use, documented arrhythmic life-threatening events were comparable [sustained ventricular tachycardia: 5.8% vs. 7.7%, ventricular fibrillation (VF) .5% vs. .6%] and consequently the rate of appropriate shocks was similar between both groups. Left ventricular ejection fraction improvement was documented over follow-up with a better improvement in younger patients as compared to older patients (77% vs. 63%, p = .002). In addition, at baseline, the rate of atrial fibrillation was significantly higher in the older age group (23% vs. 8%; p = .001). The rate of permanent cardiac implantable electronic device implantation (CiED) was lower in the younger group (25% vs. 36%, p = .05). The compliance rate defined as wearing WCD at least 20 h per day was significantly lower in young patients compared to old patients (68.9% vs. 80.9%, p < .001). During the follow-up, no significant difference regarding all-cause mortality or arrhythmic death was documented in both groups. A low compliance rate of wearing WCD is predicted by young patients and patients suffering from non-ischaemic cardiomyopathies., Conclusion: Although the compliance rate in different age groups is high, the average wear hours tended to be lower in young patients compared to older patients. The clinical events were similar in younger patients compared to older patients., (© 2023 The Authors. European Journal of Clinical Investigation published by John Wiley & Sons Ltd on behalf of Stichting European Society for Clinical Investigation Journal Foundation.)
- Published
- 2023
- Full Text
- View/download PDF
28. Characteristics and outcome of wearable cardioverter-defibrillator therapy stratified by gender: Insights from a multicenter international registry.
- Author
-
Abumayyaleh M, Koepsel K, Aweimer A, Ewers A, Erath JW, Kuntz T, Klein N, Kovacs B, Duru F, Saguner AM, Blockhaus C, Shin DI, Gotzmann M, Lapp H, Beiert T, Mügge A, El-Battrawy I, and Akin I
- Subjects
- Humans, Electric Countershock adverse effects, Registries, Death, Sudden, Cardiac prevention & control, Defibrillators, Defibrillators, Implantable, Wearable Electronic Devices
- Published
- 2023
- Full Text
- View/download PDF
29. A worldwide survey on incidence, management and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: The POTTER-AF study.
- Author
-
Tilz RR, Schmidt V, Pürerfellner H, Maury P, Chun KJ, Martinek M, Sohns C, Schmidt B, Mandel F, Gandjbakhch E, Laredo M, Gunawardene MA, Willems S, Beiert T, Borlich M, Iden L, Füting A, Spittler R, Gaspar T, Richter S, Schade A, Kuniss M, Neumann T, Francke A, Wunderlich C, Shin DI, Grosse Meininghaus D, Foresti M, Bonsels M, Reek D, Wiegand U, Bauer A, Metzner A, Eckardt L, Popescu SȘ, Krahnefeld O, Sticherling C, Kühne M, Nguyen DQ, Roten L, Saguner AM, Linz D, van der Voort P, Mulder BA, Vijgen J, Almorad A, Guenancia C, Fauchier L, Boveda S, De Greef Y, Da Costa A, Jais P, Derval N, Milhem A, Jesel L, Garcia R, Poty H, Khoueiry Z, Seitz J, Laborderie J, Mechulan A, Brigadeau F, Zhao A, Saludas Y, Piot O, Ahluwalia N, Martin C, Chen J, Antolic B, Leventopoulos G, Özcan EE, Yorgun H, Cay S, Yalin K, Botros MS, Mahmoud AT, Jędrzejczyk-Patej E, Inaba O, Okumura K, Ejima K, Khakpour H, Boyle N, Catanzaro JN, Reddy V, Mohanty S, Natale A, Blessberger H, Yang B, Stevens I, Sommer P, Veltmann C, Steven D, Vogler J, Kuck KH, Merino JL, Keelani A, and Heeger CH
- Abstract
Aims: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management and outcome are sparse., Methods and Results: This international multicenter registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553,729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed at 214 centers in 35 countries. In 78 centers 138 patients (0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (p<0.0001)) were diagnosed with an oesophageal fistula. Periprocedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8%, and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) (odds ratio 7.463 (2.414, 23.072) p<0.001)., Conclusions: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high., (© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology.)
- Published
- 2023
- Full Text
- View/download PDF
30. Author Correction: Selective optogenetic control of G q signaling using human Neuropsin.
- Author
-
Wagdi A, Malan D, Sathyanarayanan U, Beauchamp JS, Vogt M, Zipf D, Beiert T, Mansuroglu B, Dusend V, Meininghaus M, Schneider L, Kalthof B, Wiegert JS, König GM, Kostenis E, Patejdl R, Sasse P, and Bruegmann T
- Published
- 2023
- Full Text
- View/download PDF
31. Increased in vivo perpetuation of whole-heart ventricular arrhythmia in heterozygous Na + /Ca 2+ exchanger knockout mice.
- Author
-
Bögeholz N, Knappe V, Pauls P, Schulte JS, Goldhaber JI, Müller FU, Nickenig G, Eckardt L, Schrickel JW, and Beiert T
- Abstract
Aims: Na
+ /Ca2+ exchanger (NCX) upregulation in cardiac diseases like heart failure promotes as an independent proarrhythmic factor early and delayed afterdepolarizations (EADs/DADs) on the single cell level. Consequently, NCX inhibition protects against EADs and DADs in isolated cardiomyocytes. We here investigate, whether these promising cellular in vitro findings likewise apply to an in vivo setup., Methods/results: Programmed ventricular stimulation (PVS) and isoproterenol were applied to a murine heterozygous NCX-knockout model (KO) to investigate ventricular arrhythmia initiation and perpetuation compared to wild-type (WT). KO displayed a reduced susceptibility towards isoproterenol-induced premature ventricular complexes. During PVS, initiation of single or double ectopic beats was similar between KO and WT. But strikingly, perpetuation of ventricular tachycardia (VT) was significantly increased in KO (animals with VT - KO: 82 %; WT: 47 %; p = 0.0122 / median number of VTs - KO: 4.5 (1.0, 6.25); WT: 0.0 (0.0, 4.0); p = 0.0039). The median VT duration was prolonged in KO (in s; KO: 0.38 (0.19, 0.96); WT: 0.0 (0.0, 0.60); p = 0.0239). The ventricular refractory period (VRP) was shortened in KO (in ms; KO: 15.1 ± 0.7; WT: 18.7 ± 0.7; p = 0.0013)., Conclusions: Not the initiation, but the perpetuation of provoked whole-heart in vivo ventricular arrhythmia was increased in KO. As a potential mechanism, we found a significantly reduced VRP, which may promote perpetuation of reentrant ventricular arrhythmia. On a translational perspective, the antiarrhythmic concept of therapeutic NCX inhibition seems to be ambivalent by protecting from initiating afterdepolarizations but favoring arrhythmia perpetuation in vivo at least in a murine model., Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (© 2022 The Authors. Published by Elsevier B.V.)- Published
- 2022
- Full Text
- View/download PDF
32. Selective optogenetic control of G q signaling using human Neuropsin.
- Author
-
Wagdi A, Malan D, Sathyanarayanan U, Beauchamp JS, Vogt M, Zipf D, Beiert T, Mansuroglu B, Dusend V, Meininghaus M, Schneider L, Kalthof B, Wiegert JS, König GM, Kostenis E, Patejdl R, Sasse P, and Bruegmann T
- Subjects
- Animals, Humans, Light, Mammals, TRPC6 Cation Channel, Optogenetics, Signal Transduction physiology
- Abstract
G
q proteins are universally important for signal transduction in mammalian cells. The underlying kinetics and transformation from extracellular stimuli into intracellular signaling, however could not be investigated in detail so far. Here we present the human Neuropsin (hOPN5) for specific and repetitive manipulation of Gq signaling in vitro and in vivo with high spatio-temporal resolution. Properties and G protein specificity of hOPN5 are characterized by UV light induced IP3 generation, Ca2+ transients and inhibition of GIRK channel activity in HEK cells. In adult hearts from a transgenic animal model, light increases the spontaneous beating rate. In addition, we demonstrate light induced contractions in the small intestine, which are not detectable after pharmacological Gq protein block. All-optical high-throughput screening for TRPC6 inhibitors is more specific and sensitive than conventional pharmacological screening. Thus, we demonstrate specific Gq signaling of hOPN5 and unveil its potential for optogenetic applications., (© 2022. The Author(s).)- Published
- 2022
- Full Text
- View/download PDF
33. Incidence, persistence, and clinical relevance of iatrogenic atrial septal defects after percutaneous left atrial appendage occlusion.
- Author
-
Nelles D, Vij V, Al-Kassou B, Weber M, Vogelhuber J, Beiert T, Nickenig G, Schrickel JW, and Sedaghat A
- Subjects
- Cardiac Catheterization methods, Echocardiography, Transesophageal, Humans, Iatrogenic Disease epidemiology, Incidence, Retrospective Studies, Treatment Outcome, Atrial Appendage diagnostic imaging, Atrial Appendage surgery, Atrial Fibrillation complications, Heart Septal Defects, Atrial epidemiology, Heart Septal Defects, Atrial surgery, Stroke
- Abstract
Objective: To investigate the rate and clinical impact of a persisting iatrogenic atrial septal defect (iASD) after percutaneous left atrial appendage occlusion (LAAO)., Background: Percutaneous LAAO is an alternative to oral anticoagulation (OAC) for the prevention of ischemic stroke and systemic embolism in patients with atrial fibrillation (AF). Data regarding incidence and persistence of iASD after LAAO procedures and its clinical relevance is scarce., Methods: We retrospectively analyzed 144 patients that underwent LAAO at our center between 2009 and 2020 who had at least one follow-up including transesophageal echocardiography (TEE). Baseline clinical, procedural data and echocardiographic characteristics in patients with and without evidence of an iASD were compared. We furthermore determined the rate of iASD persistence over time and evaluated outcomes of patients with and without spontaneous iASD closure., Results: After a median of 92 days (IQR 75-108 days) after LAAO, 50 patients (50/144, 34.7%) showed evidence of an iASD. Patients with iASD had higher CHADS-VASc-scores (4.9±1.5 vs 4.2±1.2, p = 0.03), larger left atrial volumes (80.5±30.5 ml vs 67.1±19.7 ml, p = 0.01) and were more likely to have relevant mitral regurgitation (≥° II) (46.0% vs 12.3%, p = 0.001). LAAO procedures took longer (50.1±24.3 vs 41.1±17.8 min, p = 0.06) in patients with a persisting iASD. Furthermore, larger device sizes were implanted (24.3±3.4 mm vs 22.1±2.8 mm, p = 0.03). The presence of an iASD had no impact on RV dysfunction, thromboembolism or mortality. Spontaneous closure of an iASD was documented in 52.0% (26/50). Hereby, similar risk factors were identified for the persistence of an iASD in follow-up., (© 2021 The Authors. Echocardiography published by Wiley Periodicals LLC.)
- Published
- 2022
- Full Text
- View/download PDF
34. Cannabinoid receptor 1 signalling modulates stress susceptibility and microglial responses to chronic social defeat stress.
- Author
-
Beins EC, Beiert T, Jenniches I, Hansen JN, Leidmaa E, Schrickel JW, and Zimmer A
- Subjects
- Animals, Mice, Mice, Inbred C57BL, Pituitary-Adrenal System, Receptor, Cannabinoid, CB1 genetics, Receptors, Cannabinoid, Stress, Psychological, Microglia, Social Defeat
- Abstract
Psychosocial stress is one of the main environmental factors contributing to the development of psychiatric disorders. In humans and rodents, chronic stress is associated with elevated inflammatory responses, indicated by increased numbers of circulating myeloid cells and activation of microglia, the brain-resident immune cells. The endocannabinoid system (ECS) regulates neuronal and endocrine stress responses via the cannabinoid receptor 1 (CB1). CB1-deficient mice (Cnr1
-/- ) are highly sensitive to stress, but if this involves altered inflammatory responses is not known. To test this, we exposed Cnr1+/+ and Cnr1-/- mice to chronic social defeat stress (CSDS). Cnr1-/- mice were extremely sensitive to a standard protocol of CSDS, indicated by an increased mortality rate. Therefore, a mild CSDS protocol was established, which still induced a behavioural phenotype in susceptible Cnr1-/- mice. These mice also showed altered glucocorticoid levels after mild CSDS, suggesting dysregulation of the hypothalamic-pituitary-adrenal (HPA) axis. Mild CSDS induced weak myelopoiesis in the periphery, but no recruitment of myeloid cells to the brain. In contrast, mild CSDS altered microglial activation marker expression and morphology in Cnr1-/- mice. These microglial changes correlated with the severity of the behavioural phenotype. Furthermore, microglia of Cnr1-/- mice showed increased expression of Fkbp5, an important regulator of glucocorticoid signalling. Overall, the results confirm that CB1 signalling protects the organism from the physical and emotional harm of social stress and implicate endocannabinoid-mediated modulation of microglia in the development of stress-related pathologies.- Published
- 2021
- Full Text
- View/download PDF
35. Low-voltage shock impedance measurements: A false sense of security.
- Author
-
Parwani AS, Lacour P, Franke P, Reichert U, Christoph K, Beiert T, Supryn R, Rangasamy K, Kull T, Hohendanner F, Heinzel F, Kucher A, Boldt LH, Pieske B, and Blaschke F
- Subjects
- Aged, Aged, 80 and over, Electric Impedance, Electrocardiography, Equipment Failure Analysis, Humans, Male, Middle Aged, Defibrillators, Implantable, Electric Countershock adverse effects, Electric Countershock instrumentation
- Abstract
Background: Implantable cardioverter defibrillators use low-voltage shock impedance measurements to monitor the lead integrity. However, previous case reports suggest that low-voltage shock impedance measurements may fail to detect insulation breaches that can cause life-threatening electrical short circuits., Methods and Results: We report six cases of insulation breaches in transvenous defibrillation leads that were not obvious during standard interrogations and testing of the lead beforehand. In two cases, an electrical short circuit during commanded shock delivery for internal electrical cardioversion resulted in a total damage of the ICD generator. In one of these cases, commanded shock delivery induced ventricular fibrillation, which required external defibrillation. In two cases, a shock due to ventricular tachycardia was aborted as the shock impedance was less than 20 Ω. However, in both cases the tiny residual shock energy terminated the ventricular tachycardia. In contrast, in one case the residual energy of the aborted shock did not end ventricular fibrillation induced at defibrillator threshold testing. In one case, the ICD indicated an error code for a short circuit condition detected during an adequate shock delivery., Conclusions: This case series illustrates that low-voltage shock impedance measurements can fail to detect insulation breaches. These data suggest that in patients without a contraindication, traditional defibrillator threshold testing or high voltage synchronized shock at the time of device replacement should be considered., (© 2020 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals LLC.)
- Published
- 2021
- Full Text
- View/download PDF
36. Heart failure after pressure overload in autosomal-dominant desminopathies: Lessons from heterozygous DES-p.R349P knock-in mice.
- Author
-
Stöckigt F, Eichhorn L, Beiert T, Knappe V, Radecke T, Steinmetz M, Nickenig G, Peeva V, Kudin AP, Kunz WS, Berwanger C, Kamm L, Schultheis D, Schlötzer-Schrehardt U, Clemen CS, Schröder R, and Schrickel JW
- Subjects
- Animals, Atrioventricular Block genetics, Cardiomyopathies genetics, DNA Copy Number Variations, DNA, Mitochondrial genetics, Disease Models, Animal, Female, Gene Knock-In Techniques, Heterozygote, Humans, Male, Mice, Stroke Volume, Amino Acid Substitution, Atrioventricular Block physiopathology, Cardiomyopathies physiopathology, Desmin genetics
- Abstract
Background: Mutations in the human desmin gene (DES) cause autosomal-dominant and -recessive cardiomyopathies, leading to heart failure, arrhythmias, and AV blocks. We analyzed the effects of vascular pressure overload in a patient-mimicking p.R349P desmin knock-in mouse model that harbors the orthologue of the frequent human DES missense mutation p.R350P., Methods and Results: Transverse aortic constriction (TAC) was performed on heterozygous (HET) DES-p.R349P mice and wild-type (WT) littermates. Echocardiography demonstrated reduced left ventricular ejection fraction in HET-TAC (WT-sham: 69.5 ± 2.9%, HET-sham: 64.5 ± 4.7%, WT-TAC: 63.5 ± 4.9%, HET-TAC: 55.7 ± 5.4%; p<0.01). Cardiac output was significantly reduced in HET-TAC (WT sham: 13088 ± 2385 μl/min, HET sham: 10391 ± 1349μl/min, WT-TAC: 8097 ± 1903μl/min, HET-TAC: 5793 ± 2517μl/min; p<0.01). Incidence and duration of AV blocks as well as the probability to induce ventricular tachycardias was highest in HET-TAC. We observed reduced mtDNA copy numbers in HET-TAC (WT-sham: 12546 ± 406, HET-sham: 13526 ± 781, WT-TAC: 11155 ± 3315, HET-TAC: 8649 ± 1582; p = 0.025), but no mtDNA deletions. The activity of respiratory chain complexes I and IV showed the greatest reductions in HET-TAC., Conclusion: Pressure overload in HET mice aggravated the clinical phenotype of cardiomyopathy and resulted in mitochondrial dysfunction. Preventive avoidance of pressure overload/arterial hypertension in desminopathy patients might represent a crucial therapeutic measure., Competing Interests: The authors have declared that no competing interests exist.
- Published
- 2020
- Full Text
- View/download PDF
37. Response to letter on "Relaxin inhibits macrophage inflammation by repressing NLRP3" by Zhou et al.
- Author
-
Beiert T, Knappe V, Andrié RP, and Schrickel JW
- Subjects
- Anti-Inflammatory Agents, Arrhythmias, Cardiac, Humans, Inflammasomes, Inflammation, Macrophages, NLR Family, Pyrin Domain-Containing 3 Protein, Myocardial Infarction, Relaxin
- Published
- 2020
- Full Text
- View/download PDF
38. [Catheter ablation of cardiac arrhythmias : Forms of energy and biophysical principles].
- Author
-
Beiert T and Schrickel JW
- Subjects
- Atrial Fibrillation, Cryosurgery, Humans, Pulmonary Veins, Catheter Ablation
- Abstract
Catheter ablation of cardiac arrhythmias has evolved over the years and has become a cornerstone in the modern treatment of various supraventricular and ventricular arrhythmias. The goal of ablation is to permanently damage myocardium that is critically involved in the individual arrhythmia mechanism. Different catheters and forms of energy are available. Radiofrequency (RF) ablation is most common. Application of an alternating current at the catheter tip induces heating of tissue and, thus, leads to ablation of a targeted arrhythmogenic substrate. High temperatures (>70 °C at the catheter tip and >95 °C within the tissue) bear the risk of coagulum formation and steam pops and should be avoided, which limits power application. The evolution of irrigated RF ablation catheters enables the transfer of more power to the tissue and thereby increases the dimensions of the lesions. Cryoablation represents a valuable alternative. Cooling of tissue to -80 °C causes the intra- and extracellular formation of ice crystals, finally resulting in a dense circumscribed scar. The cryomapping procedure grants improved surveillance of the safety of ablation. Cryoenergy is very popular for pulmonary vein isolation (PVI) using the cryoballoon. In addition to the laser balloon that is established for PVI, ultrasound, microwaves, and stereotactic irradiation complete the arsenal.
- Published
- 2019
- Full Text
- View/download PDF
39. Multicenter Experience of Subcutaneous Implantable Cardioverter-Defibrillator Therapy in Patients With Dextrocardia.
- Author
-
Lüker J, Padala SK, Cano Ó, Beiert T, Osswald B, Koneru JN, Schrickel JW, Kron J, Franqui-Rivera H, Gonzalez-Cordero A, Al-Ghamdi BS, Roberts PR, Ceresnak SR, von Alvensleben J, Sultan A, and Steven D
- Subjects
- Adult, Female, Heart Defects, Congenital complications, Humans, Male, Middle Aged, Primary Prevention, Secondary Prevention, Subcutaneous Tissue, Death, Sudden, Cardiac prevention & control, Defibrillators, Implantable, Dextrocardia complications, Heart Septal Defects, Atrial complications, Heart Septal Defects, Ventricular complications, Prosthesis Implantation methods, Tetralogy of Fallot complications, Transposition of Great Vessels complications
- Published
- 2019
- Full Text
- View/download PDF
40. Increased mortality and ICD therapies in ischemic versus non-ischemic dilated cardiomyopathy patients with cardiac resynchronization having survived until first device replacement.
- Author
-
Beiert T, Straesser S, Malotki R, Stöckigt F, Schrickel JW, and Andrié RP
- Abstract
Introduction: Cardiac resynchronization therapy combined with an implantable cardioverter defibrillator (CRT-D) is widely applied in heart failure patients. Sufficient data on arrhythmia and defibrillator therapies during long-term follow-up of more than 4 years are lacking and data on mortality are conflicting. We aimed to characterize the occurrence of ventricular arrhythmia, respective defibrillator therapies and mortality for several years following CRT-D implantation or upgrade., Material and Methods: Eighty-eight patients with ischemic (ICM) or non-ischemic dilated cardiomyopathy (DCM) and at least one CRT-D replacement were included in this study and analyzed for incidence of non-sustained ventricular tachycardia (NSVT), defibrillator shocks, anti-tachycardia pacing (ATP) and mortality., Results: ICM was the underlying disease in 59%, DCM in 41% of patients. During a mean follow-up of 76.4 ±24.8 months the incidence of appropriate defibrillator therapies (shock or ATP) was 46.6% and was elevated in ICM compared to DCM patients (57.7% vs. 30.6%, respectively; p = 0.017). Kaplan-Meier analysis revealed significantly higher ICD therapy-free survival rates in DCM patients ( p = 0.031). Left ventricular ejection fraction, NSVT per year and ICM (vs. DCM) were independent predictors of device intervention. The ICM patients showed increased mortality compared to DCM patients, with cumulative all-cause mortality at 9 years of follow-up of 45.4% and 10.6%, respectively. Chronic renal failure, peripheral artery disease and chronic obstructive pulmonary disease were independent predictors of mortality., Conclusions: The clinical course of patients with ICM and DCM treated with CRT-D differs significantly during long-term follow-up, with increased mortality and incidence of ICD therapies in ICM patients., Competing Interests: The authors declare no conflict of interest.
- Published
- 2019
- Full Text
- View/download PDF
41. Optogenetic Termination of Cardiac Arrhythmia: Mechanistic Enlightenment and Therapeutic Application?
- Author
-
Sasse P, Funken M, Beiert T, and Bruegmann T
- Abstract
Optogenetic methods enable selective de- and hyperpolarization of cardiomyocytes expressing light-sensitive proteins within the myocardium. By using light, this technology provides very high spatial and temporal precision, which is in clear contrast to electrical stimulation. In addition, cardiomyocyte-specific expression would allow pain-free stimulation. In light of these intrinsic technical advantages, optogenetic methods provide an intriguing opportunity to understand and improve current strategies to terminate cardiac arrhythmia as well as for possible pain-free arrhythmia termination in patients in the future. In this review, we give a concise introduction to optogenetic stimulation of cardiomyocytes and the whole heart and summarize the recent progress on optogenetic defibrillation and cardioversion to terminate cardiac arrhythmia. Toward this aim, we specifically focus on the different mechanisms of optogenetic arrhythmia termination and how these might influence the prerequisites for success. Furthermore, we critically discuss the clinical perspectives and potential patient populations, which might benefit from optogenetic defibrillation devices.
- Published
- 2019
- Full Text
- View/download PDF
42. Optogenetic stimulation of G s -signaling in the heart with high spatio-temporal precision.
- Author
-
Makowka P, Bruegmann T, Dusend V, Malan D, Beiert T, Hesse M, Fleischmann BK, and Sasse P
- Subjects
- Animals, Calcium metabolism, Cations, Divalent, Cell Differentiation, Cyclic AMP metabolism, GTP-Binding Protein alpha Subunits, Gs metabolism, Gene Expression, Green Fluorescent Proteins genetics, Green Fluorescent Proteins metabolism, Heart Atria cytology, Heart Atria radiation effects, Heart Ventricles cytology, Heart Ventricles radiation effects, Light, Mice, Mouse Embryonic Stem Cells cytology, Mouse Embryonic Stem Cells metabolism, Mouse Embryonic Stem Cells radiation effects, Myocytes, Cardiac cytology, Myocytes, Cardiac radiation effects, GTP-Binding Protein alpha Subunits, Gs genetics, Heart Atria metabolism, Heart Ventricles metabolism, Light Signal Transduction, Myocytes, Cardiac metabolism, Optogenetics methods
- Abstract
The standard technique for investigating adrenergic effects on heart function is perfusion with pharmaceutical agonists, which does not provide high temporal or spatial precision. Herein we demonstrate that the light sensitive G
s -protein coupled receptor JellyOp enables optogenetic stimulation of Gs -signaling in cardiomyocytes and the whole heart. Illumination of transgenic embryonic stem cell-derived cardiomyocytes or of the right atrium of mice expressing JellyOp elevates cAMP levels and instantaneously accelerates spontaneous beating rates similar to pharmacological β-adrenergic stimulation. Light application to the dorsal left atrium instead leads to supraventricular extrabeats, indicating adverse effects of localized Gs -signaling. In isolated ventricular cardiomyocytes from JellyOp mice, we find increased Ca2+ currents, fractional cell shortening and relaxation rates after illumination enabling the analysis of differential Gs -signaling with high temporal precision. Thus, JellyOp expression allows localized and time-restricted Gs stimulation and will provide mechanistic insights into different effects of site-specific, long-lasting and pulsatile Gs activation.- Published
- 2019
- Full Text
- View/download PDF
43. Treatment with mononuclear cell populations improves post-infarction cardiac function but does not reduce arrhythmia susceptibility.
- Author
-
Andrié RP, Beiert T, Knappe V, Linhart M, Stöckigt F, Klein AM, Ghanem A, Lübkemeier I, Röll W, Nickenig G, Fleischmann BK, and Schrickel JW
- Subjects
- Animals, Arrhythmias, Cardiac metabolism, CD11b Antigen metabolism, Connexin 43 metabolism, Endothelial Progenitor Cells metabolism, Epicardial Mapping methods, Infarction metabolism, Leukocytes, Mononuclear metabolism, Membrane Proteins metabolism, Mice, Myocardial Infarction metabolism, Myocytes, Cardiac metabolism, Myocytes, Cardiac physiology, Tachycardia, Ventricular metabolism, Tachycardia, Ventricular therapy, Ventricular Function, Left physiology, Arrhythmias, Cardiac therapy, Infarction therapy, Leukocytes, Mononuclear physiology, Myocardial Infarction therapy
- Abstract
Background: Clinical and experimental data give evidence that transplantation of stem and progenitor cells in myocardial infarction could be beneficial, although the underlying mechanism has remained elusive. Ventricular tachyarrhythmia is the most frequent and potentially lethal complication of myocardial infarction, but the impact of mono nuclear cells on the incidence of ventricular arrhythmia is still not clear., Objective: We aimed to characterize the influence of splenic mononuclear cell populations on ventricular arrhythmia after myocardial infarction., Methods: We assessed electrical vulnerability in vivo in mice with left ventricular cryoinfarction 14 days after injury and intramyocardial injection of specific subpopulations of mononuclear cells (MNCs) (CD11b-positive cells, Sca-1-positive cells, early endothelial progenitor cells (eEPCs)). As positive control group we used embryonic cardiomyocytes (eCMs). Epicardial mapping was performed for analysing conduction velocities in the border zone. Left ventricular function was quantified by echocardiography and left heart catheterization., Results: In vivo pacing protocols induced ventricular tachycardia (VT) in 30% of non-infarcted mice. In contrast, monomorphic or polymorphic VT could be evoked in 94% of infarcted and vehicle-injected mice (p<0.01). Only transplantation of eCMs prevented post-infarction VT and improved conduction velocities in the border zone in accordance to increased expression of connexin 43. Cryoinfarction resulted in a broad aggravation of left ventricular function. All transplanted cell types augmented left ventricular function to a similar extent., Conclusions: Transplantation of different MNC populations after myocardial infarction improves left ventricular function similar to effects of eCMs. Prevention of inducible ventricular arrhythmia is only seen after transplantation of eCMs., Competing Interests: The authors have declared that no competing interests exist.
- Published
- 2019
- Full Text
- View/download PDF
44. Overexpression of the Na + /Ca 2+ exchanger influences ouabain-mediated spontaneous Ca 2+ activity but not positive inotropy.
- Author
-
Beiert T and Schrickel JW
- Subjects
- Animals, Cardiotonic Agents pharmacology, Heart Failure drug therapy, Heart Failure metabolism, Humans, Calcium metabolism, Ouabain pharmacology, Sodium-Calcium Exchanger metabolism
- Published
- 2019
- Full Text
- View/download PDF
45. Cardiac magnetic resonance using late gadolinium enhancement and atrial T1 mapping predicts poor outcome in patients with atrial fibrillation after catheter ablation therapy.
- Author
-
Luetkens JA, Wolpers AC, Beiert T, Kuetting D, Dabir D, Homsi R, Meendermann H, Dayé NA, Knappe V, Karsdal M, Nielsen SH, Genovese F, Stöckigt F, Linhart M, Thomas D, Nickenig G, Schild HH, Schrickel JW, and Andrié RP
- Subjects
- Adult, Aged, Aged, 80 and over, Atrial Fibrillation blood, Atrial Fibrillation therapy, Catheter Ablation adverse effects, Collagen Type IV blood, Connectin blood, Contrast Media administration & dosage, Female, Fibrosis blood, Fibrosis therapy, Gadolinium administration & dosage, Heart Atria diagnostic imaging, Heart Atria physiopathology, Humans, Magnetic Resonance Imaging, Male, Matrix Metalloproteinases blood, Middle Aged, Peroxidase blood, Proportional Hazards Models, Relaxin blood, Atrial Fibrillation diagnostic imaging, Atrial Fibrillation physiopathology, Fibrosis diagnostic imaging, Fibrosis physiopathology
- Abstract
To determine the pre-procedural value of different fibrotic biomarkers and comprehensive cardiac magnetic resonance (CMR) for the prediction of poor response to ablation therapy in patients with atrial fibrillation (AF). Left atrial (LA) late gadolinium enhancement (LGE) and native LA T1 relaxation times were assessed using CMR. Plasma levels of relaxin, myeloperoxidase and serum levels of matrix metalloproteinase (MMP)-mediated cardiac specific titin fragmentation and MMP-mediated type IV collagen degradation were obtained. Poor outcome was defined by the recurrence of AF during 1-year follow-up. 61 patients were included in final analysis. Twenty (32.8%) patients had recurrence of AF. Patients with a recurrence of AF had a higher percentage of LA LGE (26.7 ± 12.5% vs. 17.0 ± 7.7%; P < 0.001), higher LA T1 relaxation times (856.7 ± 112.2 ms vs. 746.8 ± 91.0 ms; P < 0.001) and higher plasma levels of relaxin (0.69 ± 1.34 pg/ml vs. 0.37 ± 0.88 pg/ml; P = 0.035). In the multivariate Cox regression analysis, poor ablation outcome was best predicted by advanced LGE stage (hazard ratio (HR):5.487; P = 0.001) and T1 relaxation times (HR:1.007; P = 0.001). Pre-procedural CMR is a valuable tool for prediction of poor response to catheter ablation therapy in patients with AF. It offers various imaging techniques for outcome prediction and might be valuable for a better patient selection prior to ablation therapy.
- Published
- 2018
- Full Text
- View/download PDF
46. Impact of Ionizing Radiation on Electrophysiological Behavior of Human-induced Ipsc-derived Cardiomyocytes on Multielectrode Arrays.
- Author
-
Becker BV, Seeger T, Beiert T, Antwerpen M, Palnek A, Port M, and Ullmann R
- Subjects
- Arrhythmias, Cardiac etiology, Cell Differentiation radiation effects, Cell Proliferation radiation effects, Cells, Cultured, Dose-Response Relationship, Radiation, Gene Expression Profiling, Humans, Induced Pluripotent Stem Cells cytology, Induced Pluripotent Stem Cells radiation effects, Myocytes, Cardiac cytology, Myocytes, Cardiac radiation effects, Arrhythmias, Cardiac pathology, Electrophysiological Phenomena radiation effects, Gene Expression Regulation radiation effects, Induced Pluripotent Stem Cells physiology, Myocytes, Cardiac physiology, Radiation, Ionizing
- Abstract
Cardiac arrhythmia presumably induced through cardiac fibrosis is a recurrent long-term consequence of exposure to ionizing radiation. However, there is also evidence that cardiac arrhythmia can occur in patients shortly after irradiation. In this study, the authors employed multielectrode arrays to investigate the short-term effects of x-ray radiation on the electrophysiological behavior of cardiomyocytes derived from human-induced pluripotent stem cells. These cardiomyocytes with spontaneous pacemaker activity were cultured on single-well multielectrode arrays. After exposure to 0, 0.5, 1, 2, 5, 10 Gy x-ray radiation, electrical activity was measured at time points ranging from 10 min to 96 h. RNA sequencing was employed to verify the expression of genes specifically involved in cardiomyocyte differentiation and function. A decrease in beating rate was observed after irradiation with 5 and 10 Gy starting 48 h after exposure. Cells exposed to higher doses of radiation were more prone to show changes in electrophysiological spatial distribution. No radiation-induced effects with respect to the corrected QT interval were detectable. Gene expression analysis showed up regulation of typical cardiac features like ACTC1 or HCN4. In this study, early dose-dependent changes in electrophysiological behavior were determined after x-ray irradiation. Results point towards a dose-dependent effect on pacemaker function of cardiomyocytes and indicate a possible connection between irradiation and short-term changes in electrophysiological cardiac function. Cardiomyocytes derived from human-induced pluripotent stem cells on multielectrode arrays represent a promising in vitro cardiac-modeling system for preclinical studies.
- Published
- 2018
- Full Text
- View/download PDF
47. High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation.
- Author
-
Linhart M, Werner JT, Stöckigt F, Kohlmann AT, Lodde PC, Linneborn LPT, Beiert T, Hammerstingl C, Borràs R, Nickenig G, Andrié RP, and Schrickel JW
- Subjects
- Aged, Analysis of Variance, Catheter Ablation methods, Cohort Studies, Cryosurgery methods, Databases, Factual, Echocardiography methods, Echocardiography, Transesophageal methods, Female, Follow-Up Studies, Germany, Heart Septal Defects, Atrial diagnostic imaging, Heart Septal Defects, Atrial epidemiology, Hospitals, University, Humans, Iatrogenic Disease epidemiology, Incidence, Male, Middle Aged, Monitoring, Physiologic, Multivariate Analysis, Proportional Hazards Models, Retrospective Studies, Risk Assessment, Survival Analysis, Time Factors, Catheter Ablation adverse effects, Cryosurgery adverse effects, Heart Septal Defects, Atrial etiology, Pulmonary Veins surgery
- Abstract
Purpose: Congenital atrial septal defect (ASD) is associated with increased morbidity, whereas little is known about the rate of spontaneous closure, associated clinical and echocardiographic parameters, or complications of iatrogenic atrial septal defect (iASD) beyond 1 year of follow-up. Persistent iASD after transseptal puncture for PVI has been described in up to 38% of small cohorts of patients in short-term follow-up after transseptal puncture. We sought to investigate the course of iASD after single transseptal puncture for first pulmonary vein isolation (PVI) with cryoballoon, along with possible risk factors for persistent iASD., Methods: After a first PVI with cryoballoon, 102 patients (64 ± 10 years, 64% male) underwent long-term clinical follow-up and comprehensive transthoracic and transesophageal echocardiographic study., Results: Prevalence of iASD after PVI was 37% after 2.9 (1.6-4.9) years. No clinical complications or deterioration of echocardiographic parameters were associated with iASD. Lower left atrial appendage flow velocity was associated with higher risk of persistence of iASD (3.5% for every 1 cm/s decrease, p = 0.002)., Conclusions: Despite a high rate of iASD after cryoballoon PVI in long-term follow-up, this was not associated with increased clinical complications. Lower LAA velocity was associated with higher risk of persistent iASD. Repeated routine echocardiographic follow-up may not be necessary in these patients.
- Published
- 2018
- Full Text
- View/download PDF
48. Optogenetic termination of atrial fibrillation in mice.
- Author
-
Bruegmann T, Beiert T, Vogt CC, Schrickel JW, and Sasse P
- Subjects
- Action Potentials, Animals, Atrial Fibrillation genetics, Atrial Fibrillation metabolism, Atrial Fibrillation physiopathology, Channelrhodopsins genetics, Channelrhodopsins metabolism, Connexins genetics, Connexins metabolism, Disease Models, Animal, Female, Genetic Predisposition to Disease, Heart Atria metabolism, KATP Channels metabolism, Male, Mice, Inbred C57BL, Mice, Transgenic, Mutation, Phenotype, Refractory Period, Electrophysiological, Tachycardia, Supraventricular genetics, Tachycardia, Supraventricular metabolism, Tachycardia, Supraventricular physiopathology, Gap Junction alpha-5 Protein, Atrial Fibrillation therapy, Atrial Function, Heart Atria physiopathology, Heart Rate, Optogenetics, Tachycardia, Supraventricular therapy
- Abstract
Aims: The primary goal in the treatment of symptomatic atrial fibrillation/flutter (AF) is to restore sinus rhythm by cardioversion. Electrical shocks are highly effective, but have to be applied under analgo-sedation and can further harm the heart. In order to develop a novel pain-free and less harmful approach, we explored herein the optogenetic cardioversion by light-induced depolarization., Methods and Results: Hearts from mice expressing Channelrhodopsin-2 (ChR2) and the AF-promoting loss-of-function Connexin 40 Ala96Ser mutation were explanted and perfused with low K+ Tyrode's solution and an atrial KATP-channel activator. This new protocol shortened atrial refractoriness as well as slowed atrial conduction and thereby enabled the induction of sustained AF. AF episodes could be terminated by epicardial illumination of the atria with focussed blue light (470 nm, 0.4 mW/mm2) with an efficacy of ∼97% (n = 17 hearts). In > 80% of cases, light directly terminated the AF episode with onset of illumination. Because similar illumination intensity was able to locally inhibit atrial activity, we propose that a light-induced block of electrical activity is responsible for reliable AF termination. The success rate was strongly depending on the illuminated area, applied light intensity and duration of illumination. Importantly, we were also able to demonstrate optogenetic termination of AF in vivo, using epicardial illumination through the open chest (n = 3 hearts). To point towards a translational potential, we systemically injected an adeno-associated virus to express ChR2 in wild type hearts. After 6-8 months, we found robust ChR2 expression in the atria, enabling light-mediated AF termination in six of seven mice tested., Conclusion: We provide the first evidence for optogenetic termination of atrial tachyarrhythmia in intact hearts from transgenic as well as wild type mice ex and in vivo. Thus, this report could lay the foundation for the development of implantable devices for pain-free termination of AF.
- Published
- 2018
- Full Text
- View/download PDF
49. Outcome in patients with left common pulmonary vein after cryoablation with second-generation cryoballoon.
- Author
-
Beiert T, Lodde PC, Linneborn LPT, Werner J, Prinz L, Stöckigt F, Linhart M, Lickfett L, Nickenig G, Schrickel JW, and Andrié RP
- Subjects
- Aged, Atrial Fibrillation diagnostic imaging, Coronary Angiography, Echocardiography, Female, Fluoroscopy, Germany, Humans, Male, Propensity Score, Recurrence, Retrospective Studies, Treatment Outcome, Atrial Fibrillation surgery, Cryosurgery instrumentation, Pulmonary Veins surgery
- Abstract
Background: Pulmonary vein isolation (PVI) has become a widely accepted therapy in patients suffering from symptomatic atrial fibrillation (AF)., Hypothesis: AF-free survival differs in patients with left common pulmonary vein (LCPV) after PVI with second-generation cryoballoon., Methods: We included patients scheduled for first PVI for paroxysmal or persistent AF. Symptomatic and/or documented arrhythmia episodes (>30 seconds) were defined as AF recurrence, excluding a 3-month blanking period., Results: We observed a LCPV in 37 of 270 consecutive patients (13.7%). Analyses were performed in a 1:1 propensity score matched cohort of 68 patients. During a median follow-up of 77.0 weeks, 37 patients (54.4%) had recurrent AF. The prevalence of LCPV was numerically higher in patients with AF recurrence (62.2% vs 35.5%, P = 0.051) and Kaplan-Meier analysis showed lower AF-free survival in patients with existence of a LCPV (P = 0.028). At 1-year follow-up, 70.6% of patients without versus 55.1% of patients with LCPV were free of AF. Multivariate Cox regression analysis revealed presence of a LCPV (hazard ratio [HR]: 2.996), chronic heart failure (HR: 3.423), and mitral regurgitation > I° (HR: 2.571) as predictors of AF recurrence., Conclusion: Patients with LCPV had significantly reduced AF-free survival after ablation with the second-generation cryoballoon, despite similar acutely successful PVIs., (© 2017 Wiley Periodicals, Inc.)
- Published
- 2018
- Full Text
- View/download PDF
50. Chronic lower-dose relaxin administration protects from arrhythmia in experimental myocardial infarction due to anti-inflammatory and anti-fibrotic properties.
- Author
-
Beiert T, Knappe V, Tiyerili V, Stöckigt F, Effelsberg V, Linhart M, Steinmetz M, Klein S, Schierwagen R, Trebicka J, Roell W, Nickenig G, Schrickel JW, and Andrié RP
- Subjects
- Animals, Arrhythmias, Cardiac metabolism, Arrhythmias, Cardiac pathology, Drug Administration Schedule, Female, Fibrosis, Male, Mice, Myocardial Infarction metabolism, Myocardial Infarction pathology, Anti-Inflammatory Agents administration & dosage, Arrhythmias, Cardiac prevention & control, Cardiotonic Agents administration & dosage, Myocardial Infarction prevention & control, Relaxin administration & dosage
- Abstract
Background: The peptide hormone relaxin-2 (RLX) exerts beneficial effects during myocardial ischemia, but functional data on lower-dose RLX in myocardial infarction (MI) is lacking. Therefore, we investigated the impact of 75μg/kg/d RLX treatment on electrical vulnerability and left ventricular function in a mouse model of MI., Methods and Results: Standardized cryoinfarction of the left anterior ventricular wall was performed in mice. A two week treatment period with vehicle or RLX via subcutaneously implanted osmotic minipumps was started immediately after MI. The relaxin receptor RXFP1 was expressed on ventricular/atrial cardiomyocytes, myofibroblasts, macrophages and endothelial but not vascular smooth muscle cells of small coronary vessels. RLX treatment resulted in a significant reduction of ventricular tachycardia inducibility (vehicle: 91%, RLX: 18%, p<0.0001) and increased epicardial conduction velocity in the left ventricle and borderzone. Furthermore, left ventricular function following MI was improved in RLX treated mice (left ventricular ejection fraction; vehicle: 41.1±1.9%, RLX: 50.5±3.5%, p=0.04). Interestingly, scar formation was attenuated by RLX with decreased transcript expression of connective tissue growth factor. Transcript levels of the pro-inflammatory cytokines interleukin-6 and interleukin-1β were upregulated in hearts of vehicle treated animals compared to mice without MI. Application of RLX attenuated this inflammatory response. In addition, macrophage infiltration was reduced in the borderzone of RLX treated mice., Conclusion: Treatment with lower-dose RLX in mice prevents post-infarction ventricular tachycardia due to attenuation of scar formation and cardiac inflammation. Therefore, RLX could be evaluated as new therapeutic option in the treatment of MI., (Copyright © 2017 Elsevier B.V. All rights reserved.)
- Published
- 2018
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.