50 results on '"Benmakhlouf, H."'
Search Results
2. PO-1925 The extra- and intra-fraction stability of the new Vantage stereotactic system used in Gamma Knife
- Author
-
Benmakhlouf, H., primary, Fager, M., additional, Samadi, A., additional, Gubanski, M., additional, and Ghazal, M., additional
- Published
- 2023
- Full Text
- View/download PDF
3. PO-1819 Dose-to-medium and dose-to-water in photon radiotherapy dose calculations
- Author
-
Ghazal, M., primary and Benmakhlouf, H., additional
- Published
- 2023
- Full Text
- View/download PDF
4. MO-0476 On the configuration of small SRT beams: a protocol for accurate parameterization of a beam model
- Author
-
Ghazal, M., primary, Melhus, T., additional, and Benmakhlouf, H., additional
- Published
- 2023
- Full Text
- View/download PDF
5. 82 Juvenile dermatomyositis with early-onset anti-MDA 5 antibodies: a case report
- Author
-
Ayad, N, primary, Gherbi, M, additional, Gacem, O, additional, Falek, H, additional, Labboun, L, additional, Amirat, L, additional, Chouli, M, additional, Abba, K, additional, Benmakhlouf, H, additional, Achir, M, additional, and Ladj, M. S, additional
- Published
- 2022
- Full Text
- View/download PDF
6. Metastatic renal cell carcinoma to the brain : optimizing patient selection for gamma knife radiosurgery
- Author
-
Stenman, Maria, Benmakhlouf, H., Wersäll, P., Johnstone, P., Hatiboglu, M. A., Mayer-da-Silva, J., Harmenberg, U., Lindskog, Magnus, Sinclair, G., Stenman, Maria, Benmakhlouf, H., Wersäll, P., Johnstone, P., Hatiboglu, M. A., Mayer-da-Silva, J., Harmenberg, U., Lindskog, Magnus, and Sinclair, G.
- Abstract
Introduction The effects of single-fraction gamma knife radiosurgery (sf-GKRS) on patients with renal cell carcinoma (RCC) brain metastases (BM) in the era of targeted agents (TA) and immune checkpoint inhibitors (ICI) are insufficiently studied. Methods and materials Clear cell metastatic RCC patients treated with sf-GKRS due to BM in 2005–2014 at three European centres were retrospectively analysed (n = 43). Median follow-up was 56 months. Ninety-five percent had prior nephrectomy, 53% synchronous metastasis and 86% extracranial disease at first sf-GKRS. Karnofsky performance status (KPS) ranged from 60 to 100%. Outcome measures were overall survival (OS), local control (LC) and adverse radiation effects (ARE). Results One hundred and ninety-four targets were irradiated. The median number of targets at first sf-GKRS was two. The median prescription dose was 22.0 Gy. Thirty-seven percent had repeated sf-GKRS. Eighty-eight percent received TA. LC rates at 12 and 18 months were 97% and 90%. Median OS from the first sf-GKRS was 15.7 months. Low serum albumin (HR for death 5.3), corticosteroid use pre-sf-GKRS (HR for death 5.8) and KPS < 80 (HR for death 9.1) were independently associated with worse OS. No further prognostic information was gleaned from MSKCC risk group, synchronous metastasis, age, number of BM or extracranial metastases. Other prognostic scores for BM radiosurgery, including DS-GPA, renal-GPA, LLV-SIR and CITV-SIR, again, did not add further prognostic value. ARE were seldom symptomatic and were associated with tumour volume, 10-Gy volume and pre-treatment perifocal oedema. ARE were less common among patients treated with TA within 1 month of sf-GKRS. Conclusions We identified albumin, corticosteroid use and KPS as independent prognostic factors for sf-GKRS of clear cell RCC BM. Studies focusing on the prognostic significance of albumin in sf-GKRS are rare. Further studies with a larger number of patients are warranted to confirm the above analyti, De två första författarna delar förstaförfattarskapetDe tre sista författarna delar sistaförfattarskapet
- Published
- 2021
- Full Text
- View/download PDF
7. Chaleurs De Melanges A 303,15 K Des Systčmes Ternaires : Piperidine(1) + benzčne(2) + cyclohexane(3) et piperidine(1) + benzčne(2) + n-octane(3)
- Author
-
Sifaoui, H., Ait-kaci, A., and Benmakhlouf, H.
- Published
- 2000
- Full Text
- View/download PDF
8. Metastatic renal cell carcinoma to the brain: optimizing patient selection for gamma knife radiosurgery
- Author
-
Stenman, M., primary, Benmakhlouf, H., additional, Wersäll, P., additional, Johnstone, P., additional, Hatiboglu, M. A., additional, Mayer-da-Silva, J., additional, Harmenberg, U., additional, Lindskog, M., additional, and Sinclair, G., additional
- Published
- 2020
- Full Text
- View/download PDF
9. Adaptive radiosurgery based on two simultaneous dose prescriptions in the management of large renal cell carcinoma brain metastases in critical areas: Towards customization
- Author
-
Sinclair, Georges, Stenman, M., Benmakhlouf, H., Johnstone, P., Wersäll, P., Lindskog, M., Hatiboglu, M. A., Harmenberg, U., Sinclair, Georges, Stenman, M., Benmakhlouf, H., Johnstone, P., Wersäll, P., Lindskog, M., Hatiboglu, M. A., and Harmenberg, U.
- Published
- 2020
- Full Text
- View/download PDF
10. Adaptive radiosurgery based on two simultaneous dose prescriptions in the management of large renal cell carcinoma brain metastases in critical areas: Towards customization
- Author
-
Sinclair, Georges, primary, Stenman, M., additional, Benmakhlouf, H., additional, Johnstone, P., additional, Wersäll, P., additional, Lindskog, M., additional, Hatiboglu, M. A., additional, and Harmenberg, U., additional
- Published
- 2020
- Full Text
- View/download PDF
11. EP-1728: Small field dosimetry formalism implemented using various detectors on several linear accelerators
- Author
-
Ghazal, M., primary, Carlsson-Tedgren, A., additional, and Benmakhlouf, H., additional
- Published
- 2018
- Full Text
- View/download PDF
12. The role of radiosurgery in the acute management of fourth ventricle compression due to brain metastases
- Author
-
Sinclair, G, primary, Benmakhlouf, H, additional, Martin, H, additional, Brigui, M, additional, Maeurer, M, additional, and Dodoo, E, additional
- Published
- 2018
- Full Text
- View/download PDF
13. SU-F-T-367: Using PRIMO, a PENELOPE-Based Software, to Improve the Small Field Dosimetry of Linear Accelerators
- Author
-
Benmakhlouf, H, primary, Brualla, L, additional, Andreo, P, additional, and Sempau, J, additional
- Published
- 2016
- Full Text
- View/download PDF
14. TH‐AB‐201‐09
- Author
-
Mirzakhanian, L, primary, Benmakhlouf, H, additional, and Seuntjens, J, additional
- Published
- 2016
- Full Text
- View/download PDF
15. SU‐E‐T‐432: Field Size Influence On the Electron and Photon Spectra Within Small MV Field Detectors
- Author
-
Benmakhlouf, H, primary and Andreo, P, additional
- Published
- 2015
- Full Text
- View/download PDF
16. P-123 – Vascularites et connectivites de l'enfant
- Author
-
Ayad, N., primary, Fernini, F., additional, Gherbi, M., additional, Boudiaf, H., additional, Guers, S., additional, Khelfat, F., additional, Benmakhlouf, H., additional, Fernane, L., additional, Hamadouche, N., additional, Aouabed, Y., additional, and Achir, M., additional
- Published
- 2015
- Full Text
- View/download PDF
17. Monte Carlo calculated and experimentally determined output correction factors for small field detectors in Leksell Gamma Knife Perfexion beams
- Author
-
Benmakhlouf, H, primary, Johansson, J, additional, Paddick, I, additional, and Andreo, P, additional
- Published
- 2015
- Full Text
- View/download PDF
18. SU-E-J-240: The Impact On Clinical Dose-Distributions When Using MR-Images Registered with Stereotactic CT-Images in Gamma Knife Radiosurgery
- Author
-
Benmakhlouf, H, primary, Wangerid, T, additional, Kraepelien, T, additional, and Forander, P, additional
- Published
- 2014
- Full Text
- View/download PDF
19. OC-0511: Monte Carlo calculated output correction factors for nine small field detectors in Varian Clinac iX 6 MV photon beams
- Author
-
Benmakhlouf, H., primary, Sempau, J., additional, and Andreo, P., additional
- Published
- 2014
- Full Text
- View/download PDF
20. SU‐E‐T‐29: Monte Carlo Calculated Output Corrections Factors K(Q,f‐Clin) for Varian_Clinac‐IX 6MV Small Fields
- Author
-
Benmakhlouf, H, primary, Sempau, J, additional, and Andreo, P, additional
- Published
- 2013
- Full Text
- View/download PDF
21. SU-E-T-30: Monte Carlo Calculated Detector Corrections K(Q, F-Clin) for Determination of Output Factors for the Leksell Gamma Knife
- Author
-
Benmakhlouf, H, primary, Johansson, J, additional, and Andreo, P, additional
- Published
- 2012
- Full Text
- View/download PDF
22. P121 - Les atteintes neuropsychiatriques dans le lupus érythémateux systémique
- Author
-
Chikhi, S., primary, Djamouh, K., additional, Benmakhlouf, H., additional, Fernini, F., additional, Boudiaf, H., additional, Hamadouche, N., additional, Aouabed, Y., additional, Guers, S., additional, Ayad, N., additional, and Achir, M., additional
- Published
- 2010
- Full Text
- View/download PDF
23. Rhabdomyosarcome alvéolaire périanale métastatique aux seins
- Author
-
Rhissassi, K., Hali, F., Benmakhlouf, H., Aksim, M., Zamiati, S., Chbani, K., L.Ouzidane, Benchekkroun, S., and Benchikhi, H.
- Published
- 2013
- Full Text
- View/download PDF
24. Manifestations dermatologiques de la maladie de Kawasaki : étude prospective portant sur 93 cas
- Author
-
Boudiaf, H., Fernane, L., Hamadouche, H., Aouabed, Y., Fernini, F., Ayad, N., Gherbi, M., Guers, S., Khelfat, Benmakhlouf, H., and Achir, M.
- Published
- 2012
- Full Text
- View/download PDF
25. Adaptation of dose-prescription for vestibular schwannoma radiosurgery taking body contouring method and heterogeneous material into account.
- Author
-
Fager M, Gubanski M, Carlsson Tedgren Å, and Benmakhlouf H
- Subjects
- Humans, Magnetic Resonance Imaging, Female, Middle Aged, Male, Aged, Organs at Risk radiation effects, Adult, Radiosurgery methods, Neuroma, Acoustic radiotherapy, Neuroma, Acoustic surgery, Neuroma, Acoustic pathology, Neuroma, Acoustic diagnostic imaging, Radiotherapy Dosage, Radiotherapy Planning, Computer-Assisted methods, Algorithms
- Abstract
Background: Majority of vestibular schwannoma (VS) patients have undergone gamma-knife radiosurgery (GKRS) with favorable results. Clinical evidence is derived from doses calculated with a type-a algorithm, which in this case assumes all material to be water. A type-b algorithm (Convolution algorithm [CA]) taking tissue heterogeneity into account is available. Historically, body contour is defined using a 16-point approximation, whereas modern softwares generate the body from Magnetic Resonance Imaging (MRI). The accuracy in dose-calculation algorithms (DCA) and contouring method (CM) will have a significant influence in the relation between clinical outcome and dosimetric data. The objective was to investigate the impact of DCA and CMs on dose distribution while preserving treatment conditions., Methods: Treatment plans for 16 VS patients were recalculated in terms of DCA and CM. The difference in the dose covering 99% of the VS (DVS99%) depending on CM and DCA was estimated. The difference in DVS99% was used to adopt the prescription of new CA-based plans. CA-plans were recalculated to TMR10 to evaluate clinical treatability, as clinical evidence is derived from TMR10-doses., Results: Both CM and DCA had a significant impact on the dose to VS and surrounding structures. CM altered the doses homogenously by 2.1-3.3%, whereas DCA heterogeneously by 5.0-10.7%. An increase of 9.1[8.1, 10.0]% was found for DVS99% and the CA-plans recalculated into TMR10 resulted in clinically treatable plans., Interpretation: We conclude that transferring to more modern algorithms that take tissue heterogeneity into account heterogeneously alter dose distributions. This work establishes a safe pathway to adopt prescription dose for VS while preserving clinical treatability.
- Published
- 2025
- Full Text
- View/download PDF
26. Characterization of the radiation field surrounding the Leksell Gamma Knife® and shielding applications.
- Author
-
Matias LDS, Benmakhlouf H, Doncel M, Johansson J, Kjäll P, Nordström H, Preston M, and Tegnér PE
- Abstract
The aim of this study is to improve the characterization and modeling of the radiation field surrounding the Leksell Gamma Knife®-Perfexion
TM . The improved characterization of the radiation field enables more accurate shielding calculations to be performed for the areas adjacent to the treatment room. With the aid of a high-purity germanium detector and a satellite dose rate meter, γ-ray spectra and ambient dose equivalent H*(10) data were acquired at various locations in the field of a Leksell Gamma Knife unit in a treatment room at Karolinska University Hospital, Sweden. These measurements were used to validate the results of the PEGASOS Monte Carlo simulation system with a PENELOPE kernel. The levels of the radiation that passes through the shielding of the machine (leakage radiation) are shown to be much lower than what is suggested by various bodies, e.g. the National Council on Radiation Protection and Measurements, to be used when calculating radiation shielding barriers. The results clearly indicate that Monte Carlo simulations may be used in structural shielding design calculations for γ rays from the Leksell Gamma Knife., Competing Interests: Declaration of Competing Interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: The authors: Jonas Johansson, Per Kjäll, and Håkan Nordström are employees at Elekta Instrument AB (Stockholm, Sweden)., (Copyright © 2023 The Author(s). Published by Elsevier Ltd.. All rights reserved.)- Published
- 2023
- Full Text
- View/download PDF
27. On the stability of Leksell Vantage stereotactic head frame fixation in Gamma Knife radiosurgery: a study based on cone-beam computed tomography imaging and the High Definition Motion Management system.
- Author
-
Ghazal M, Fager M, Samadi A, Gubanski M, and Benmakhlouf H
- Subjects
- Humans, Radiotherapy Dosage, Imaging, Three-Dimensional, Cone-Beam Computed Tomography methods, Radiosurgery methods, Radiotherapy, Image-Guided methods
- Abstract
Objective: The authors' objective was to investigate the stability of the newly introduced Vantage stereotactic frame fixation in single-fraction Gamma Knife radiosurgery., Methods: A total of 255 patients were included in this work and treated with the Vantage frame and Leksell Gamma Knife (LGK) Icon equipped with cone-beam computed tomography (CBCT) imaging. After the frame was mounted on the patient's head, a CT scan was acquired. After the patient was positioned on the couch of LGK, CBCT was acquired to verify the target position before treatment delivery. A second CBCT examination was acquired after treatment delivery to assess intrafractional motion. During treatment delivery, the High Definition Motion Management (HDMM) system was enabled to track a marker on the nose tip of the patient as a surrogate of intracranial motion. The stability of the Vantage frame was deconstructed into two parts: 1) motion between CT and the first CBCT prior to treatment delivery (CT-CBCT1), and 2) motion between CBCT procedures during treatment delivery (CBCT1-CBCT2). Transformation between CT and CBCT1 was given by Leksell GammaPlan, whereas transformation between CBCT1 and CBCT2 required mathematical processing of the transformation and coregistration matrices in the source files., Results: The average CT-CBCT1 displacement vector was 0.31 mm, with a range as great as 1.09 mm, and 89% and 97% of cases were within 0.5 mm and 0.7 mm, respectively. The CBCT1-CBCT2 displacement vectors averaged at 0.09 mm, with 97% of cases being within 0.2 mm. Spatial shift in the posterior direction was evident, with 94% of cases demonstrating this trend and averaging 0.05 mm. This was attributed to increased pressure on the posterior fixation pins. The HDMM displacement vectors presented larger values with an average of 0.4 mm and a range as great as 1.6 mm, and 98% of cases were within 1.0 mm. The correlation between CBCT1-CBCT2 and HDMM displacements was weak, which was attributed to the high stability of the Vantage frame and consequently small target displacements coupled with the sensitivity of HDMM to face mimics., Conclusions: This work demonstrated that the Vantage frame possess the same degree of submillimeter stability as the well-established Leksell Coordinate Frame G (G-frame). Displacements between CT and CBCT1 were 3 times higher than between CBCT1 and CBCT2. A suggested HDMM threshold of 1.2 mm ensures a target accuracy within 0.2 mm in Vantage frame treatments.
- Published
- 2023
- Full Text
- View/download PDF
28. Experimental investigation of TRS-483 reference dosimetry correction factors for Leksell Gamma Knife® Icon™ beams.
- Author
-
Häger W, Kaveckyte V, and Benmakhlouf H
- Subjects
- International Agencies, Models, Theoretical, Phantoms, Imaging, Photons, Radiometry, Water, Radiosurgery
- Abstract
Purpose: Radiosurgery using the Leksell Gamma Knife® (LGK) Icon™ is an established technique used for treating intracranial lesions. The largest beam field size the LGK Icon can produce is a 16 mm diameter sphere. Despite this, reference dosimetry on the LGK Icon is typically performed using ionization chambers calibrated in 10 × 10 cm
2 fields. Furthermore, plastic phantoms are widely used instead of liquid water phantoms. In an effort to resolve these issues, the International Atomic Energy Agency (IAEA) in collaboration with American Association of Physicists in medicine (AAPM) recently published Technical Report Series No. 483 (TRS-483) as a Code of Practice for small-field dosimetry. TRS-483 includes small-field correction factors, k Q msr , Q 0 f msr , f ref , intended to account for the differences between setups when using small-field modalities such as the LGK Icon, and conventional setups. Since the publication of TRS-483, at least three new sets of values of k Q msr , Q 0 f msr , f ref for the LGK Icon have been published. The purpose of this study was to experimentally investigate the published values of k Q msr , Q 0 f msr , f ref for commonly used phantom and ionization chamber (IC) models for the LGK Icon., Methods: Dose-rates from two LGK units were determined using acrylonitrile butadiene styrene (ABS) and Certified Medical Grade Solid Water® (SW) phantoms, and PTW 31010 and PTW 31016 ICs. Correction factors were applied, and the resulting dose-rates compared. Relative validity of the correction factors was investigated by taking the ratios of dose-rate correction factor products. Additionally, dose-rates from the individual sectors were determined in order to calculate the beam attenuation caused by the ABS phantom adapter., Results and Conclusions: It was seen that the dose-rate is underestimated by at least 1% when using the ABS phantom, which was attributed to fluence perturbation caused by the IC and phantom adapter. Published correction factors k Q msr , Q 0 f msr , f ref account for these effects to varying degree and should be used. The SW phantom is unlikely to underestimate the dose-rate by more than 1%, and applying k Q msr , Q 0 f msr , f ref could not be shown to be necessary. Out of the two phantom models, the ABS phantom is not recommended for use in LGK reference dosimetry. The use of newly published values of k Q msr , Q 0 f msr , f ref should be considered., (© 2020 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.)- Published
- 2021
- Full Text
- View/download PDF
29. Investigation of a synthetic diamond detector response in kilovoltage photon beams.
- Author
-
Kaveckyte V, Persson L, Malusek A, Benmakhlouf H, Alm Carlsson G, and Carlsson Tedgren Å
- Subjects
- Calibration, Iodine Radioisotopes therapeutic use, Monte Carlo Method, Diamond, Phantoms, Imaging, Photons therapeutic use, Radiometry instrumentation
- Abstract
Purpose: An important characteristic of radiation dosimetry detectors is their energy response which consists of absorbed-dose and intrinsic energy responses. The former can be characterized using Monte Carlo (MC) simulations, whereas the latter (i.e., detector signal per absorbed dose to detector) is extracted from experimental data. Such a characterization is especially relevant when detectors are used in nonrelative measurements at a beam quality that differs from the calibration beam quality. Having in mind the possible application of synthetic diamond detectors (microDiamond PTW 60019, Freiburg, Germany) for nonrelative dosimetry of low-energy brachytherapy (BT) beams, we determined their intrinsic and absorbed-dose energy responses in 25-250 kV beams relative to a
60 Co beam, which is usually the reference beam quality for detector calibration in radiotherapy., Material and Methods: Three microDiamond detectors and, for comparison, two silicon diodes (PTW 60017) were calibrated in terms of air-kerma free in air in six x-ray beam qualities (from 25 to 250 kV) and in terms of absorbed dose to water in a60 Co beam at the national metrology laboratory in Sweden. The PENELOPE/penEasy MC radiation transport code was used to calculate the absorbed-dose energy response of the detectors (modeled based on blueprints) relative to air and water depending on calibration conditions. The MC results were used to extract the relative intrinsic energy response of the detectors from the overall energy response. Measurements using an independent setup with a single ophthalmic BEBIG I25.S16125 I BT seed (effective photon energy of 28 keV) were used as a qualitative check of the extracted intrinsic energy response correction factors. Additionally, the impact of the thickness of the active volume as well as the presence of extra-cameral components on the absorbed-dose energy response of a microDiamond detector was studied using MC simulations., Results: The relative intrinsic energy response of the microDiamond detectors was higher by a factor of 2 in 25 and 50 kV beams compared to the60 Co beam. The variation in the relative intrinsic energy response of silicon diodes was within 10% over the investigated photon energy range. The use of relative intrinsic energy response correction factors improved the agreement among the absorbed dose to water values determined using microDiamond detectors and silicon diodes, as well as with the TG-43 formalism-based calculations for the125 I seed. MC study of microDiamond detector design features provided a possible explanation for inter-detector response variation at low-energy photon beams by differences in the effective thickness of the active volume., Conclusions: MicroDiamond detectors had a non-negligible variation in the relative intrinsic energy response (factor of 2) which was comparable to that in the absorbed-dose energy response relative to water at low-energy photon beams. Silicon diodes, in contrast, had an absorbed-dose energy dependence on photon energy that varied by a factor of 6, whereas the intrinsic energy dependence on beam quality was within 10%. It is important to decouple these two responses for a full characterization of detector energy response especially when the user and reference beam qualities differ significantly, and MC alone is not enough., (© 2019 American Association of Physicists in Medicine.)- Published
- 2020
- Full Text
- View/download PDF
30. Integrating navigated transcranial magnetic stimulation motor mapping in hypofractionated and single-dose gamma knife radiosurgery: A two-patient case series and a review of literature.
- Author
-
Islam M, Cooray G, Benmakhlouf H, Hatiboglu M, and Sinclair G
- Abstract
Background: The aim of the study was to demonstrate the feasibility of integrating navigated transcranial magnetic stimulation (nTMS) in preoperative gamma knife radiosurgery (GKRS) planning of motor eloquent brain tumors., Case Description: The first case was a 53-year-old female patient with metastatic breast cancer who developed focal epileptic seizures and weakness of the left hand. The magnetic resonance imaging (MRI) scan demonstrated a 30 mm metastasis neighboring the right precentral gyrus and central sulcus. The lesion was treated with adaptive hypofractionated GKRS following preoperative nTMS-based motor mapping. Subsequent follow-up imaging (up to 12 months) revealed next to complete tumor ablation without toxicity. The second case involved a previously healthy 73-year-old male who similarly developed new left-handed weakness. A subsequent MRI demonstrated a 26 mm metastatic lesion, located in the right postcentral gyrus and 5 mm from the hand motor area. The extracranial screening revealed a likely primary lung adenocarcinoma. The patient underwent preoperative nTMS motor mapping prior to treatment. Perilesional edema was noted 6 months postradiosurgery; nevertheless, long- term tumor control was demonstrated. Both patients experienced motor function normalization shortly after treatment, continuing to final follow-up., Conclusion: Integrating preoperative nTMS motor mapping in treatment planning allowed us to reduce dose distributions to perilesional motor fibers while achieving salvage of motor function, lasting seizure freedom, and tumor control. These initial data along with our review of the available literature suggest that nTMS can be of significant assistance in brain radiosurgery. Prospective studies including larger number of patients are still warranted., Competing Interests: There are no conflicts of interest., (Copyright: © 2019 Surgical Neurology International.)
- Published
- 2020
- Full Text
- View/download PDF
31. 6-MV small field output factors: intra-/intermachine comparison and implementation of TRS-483 using various detectors and several linear accelerators.
- Author
-
Ghazal M, Westermark M, Kaveckyte V, Carlsson-Tedgren Å, and Benmakhlouf H
- Subjects
- Electrical Equipment and Supplies, Monte Carlo Method, Photons therapeutic use, Particle Accelerators, Radiometry instrumentation
- Abstract
Purpose: To investigate the applicability of output correction factors reported in TRS-483 on 6-MV small-field detector-reading ratios using four solid-state detectors. Also, to investigate variations in 6-MV small-field output factors (OF) among nominally matched linear accelerators (linacs)., Methods: The TRS-483 Code of Practice (CoP) introduced and provided output correction factors to be applied to measured detector-reading ratios to obtain OFs for several small-field detectors. Detector readings for 0.5 cm × 0.5 cm to 8 cm × 8 cm fields were measured and normalized to that of 10 cm × 10 cm field giving the detector-reading ratios. Three silicon diodes, IBA PFD, IBA EFD (IBA, Schwarzenbruck, Germany), PTW T60017, and one microdiamond, PTW T60019 (PTW, Freiburg, Germany), were used. Output correction factors from the CoP were applied to measured detector-reading ratios. Measurements were performed on six Clinac and six TrueBeam linacs (Varian Medical Systems, Palo Alto, USA). An investigation of the relationship between the size of small fields and corresponding detector-reading ratio among the linacs was performed by measuring lateral dose profiles for 0.5 cm × 0.5 cm fields to determine the full width half maximum (FWHM). The relationship between the linacs' focal spot size and the small-field detector-reading ratio was investigated by measuring 10 cm × 10 cm lateral dose profiles and determining the penumbra width reflecting the focal spot size. Measurement geometry was as follows: gantry angle = 0°, collimator angle = 0°, source-to surface distance (SSD) = 90 cm, and depth in water = 10 cm., Results: For a given linac and 0.5 cm × 0.5 cm field, the deviations in detector-reading ratios among the detectors were 9%-15% for the Clinacs and 4%-5% for the TrueBeams. Use of output correction factors reduced these deviations to 6%-12% and 3%-4%, respectively. For field sizes equal to or larger than 0.8 cm × 0.8 cm, the deviations were corrected to 1% using output correction factors for both Clinacs and TrueBeams. For a given detector and 0.5 cm × 0.5 cm field, the deviations in detector-reading ratios among the linacs were 11%-17% for the Clinacs and 5-6% for the TrueBeams. For 1 cm × 1 cm the deviations were 1%-2% for Clinacs and 1% for TrueBeams. For field sizes larger than 1 cm × 1 cm the deviations were within 1% for both Clinacs and TrueBeams. No relationship between FWHMs and detector-reading ratios for 0.5 cm × 0.5 cm was observed. For Clinacs, larger 10 cm × 10 cm penumbra width yielded lower 0.5 cm × 0.5 cm detector-reading ratio indicating an effect of the focal spot size. For TrueBeams, the spread of penumbra widths was lower compared to Clinacs and no similar relationship was observed., Conclusions: Output correction factors from the TRS-483 CoP are not sufficient for accurate determination of OF for 0.5 cm × 0.5 cm fields but are applicable for 0.8 cm × 0.8 cm to 8 cm × 8 cm fields. Nominally matched Clinacs and TrueBeams show large differences in detector-reading ratios for fields smaller than 1 cm × 1 cm., (© 2019 American Association of Physicists in Medicine.)
- Published
- 2019
- Full Text
- View/download PDF
32. Adaptive hybrid surgery analysis (AHSA) for adjuvant gamma knife radiosurgery treatment of vestibular schwannoma residuals.
- Author
-
Bartek J Jr, Wangerid T, Pettersson-Segerlind J, Benmakhlouf H, and Förander P
- Subjects
- Adult, Aged, Aged, 80 and over, Female, Humans, Male, Middle Aged, Neoplasm, Residual, Neuroma, Acoustic surgery, Neurosurgical Procedures, Organs at Risk, Radiotherapy Dosage, Retrospective Studies, Neuroma, Acoustic radiotherapy, Radiosurgery methods, Radiotherapy Planning, Computer-Assisted methods, Software
- Abstract
Objectives: Adaptive Hybrid Surgery Analysis (AHSA, Brainlab, Munich, Germany) is a software application generating in real-time conceptual dose plans for tumor residuals but has so far not been assessed for usability in a Gamma Knife (Elekta, Stockholm, Sweden) radiosurgery practice. We aimed to compare AHSA stereotactic radiosurgery dose plans with Leksell Gamma Plan (LGP, Elekta, Stockholm, Sweden) plans for adjuvant radiosurgical treatment of Vestibular Schwannoma (VS) residuals., Patients and Methods: In this retrospective comparative study, we compared the automatically calculated AHSA dose plans with clinical LGP treatment plans in 13 patients radiosurgically treated for VS residuals. We first created an LGP template based on our specific constraints to organs at risk (OAR), and a tumor prescription volume coverage of minimum 98%. As most proximal anatomy at risk is not manually contoured in our practice, OARs (i.e. brainstem, optic apparatus and cochlea) in the planning images were automatically segmented in Elements Anatomical Mapping and imported into the AHSA software for re-planning and comparison with the LGP dose plans., Results: There was no significant difference in tumor coverage and conformity index between the LGP and AHSA dose planning data, with the mean and maximal dose to the brainstem slightly higher in the latter., Conclusion: The AHSA dose plans for adjuvant radiosurgical treatment of VS residuals were comparable to those of LGP used in our Gamma Knife practice, confirming the usability of AHSA in the management of Vestibular Schwannoma in a Gamma Knife practice., (Copyright © 2019 Elsevier B.V. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF
33. Pituitary carcinomas: Rare and challenging.
- Author
-
Sinclair G, Olsson M, Benmakhlouf H, Al-Saffar Y, Johnstone P, Hatiboglu MA, and Shamikh A
- Abstract
Background: Pituitary carcinomas (PCs) are defined as adenohypophyseal tumors with metastatic activity within and outside the boundaries of the central nervous system (CNS). The condition is rare and therefore seldom reported; most lesions are hormone producing and have a tendency for complex evolution. As such, the management of PCs remains difficult. We present an illustrative case of PC with a brief review of the recent medical literature., Case Description: A 58-year-old patient was diagnosed with prolactinoma in 2005. The ensuing biochemical and radiological evolution proved contentious; local tumor control was never fully achieved despite multimodal management including pharmacological treatment, repeated resections, and radiotherapy. In late 2017, the patient developed metastatic lesions within the confinements of the CNS requiring further surgical interventions, high-dose radiation, and systemic treatment., Conclusion: As it was the case in our patient, PCs require tailored, multimodal treatments according to the degree of infiltration, site of invasion, and hormone status. Further studies are necessary to understand the mechanisms promoting "extra-sellar" activity, particularly at distant sites; the identification of biomarkers exposing the risk of PC remains a crucial aspect of diagnostics, prevention and future customized therapies., Competing Interests: There are no conflicts of interest.
- Published
- 2019
- Full Text
- View/download PDF
34. Adaptive hypofractionated gamma knife radiosurgery in the acute management of brainstem metastases.
- Author
-
Sinclair G, Benmakhlouf H, Martin H, Maeurer M, and Dodoo E
- Abstract
Background: Intrinsic brainstem metastases are life-threatening neoplasms requiring rapid, effective intervention. Microsurgery is considered not feasible in most cases and systemic treatment seldom provides a successful outcome. In this context, radiation therapy remains the best option but adverse radiation effects (ARE) remain a major concern. A dose-adaptive gamma knife procedure coined as Rapid Rescue Radiosurgery (3R) offers the possibility to treat these lesions whilst reducing the risk of ARE evolvement. We report the results of 3R applied to a group of patients with brainstem metastases., Methods: Eight patients with nine brainstem metastases, having undergone three separate, dose-adapted gamma knife radiosurgery (GKRS) procedures over 7 days, were retrospectively analyzed in terms of tumor volume reduction, local control rates, and ARE-development under the period of treatment and at least 6 months after treatment completion., Results: Mean peripheral doses at GKRS 1, GKRS 2, and GKRS 3 were 7.4, 7.7, and 8.2 Gy (range 6-9 Gy) set at the 35-50% isodose lines. Mean tumor volume reduction between GKRS 1 and GKRS 3 was -15% and -56% at first follow-up. Four patients developed radiologic signs of ARE but remained clinically asymptomatic. One patient developed a local recurrence at 34 months. Mean survival from GKRS 1 was 13 months. Two patients were still alive at the time of paper submission (10 and 23 months from GKRS 1)., Conclusions: In this study, 3R proved effective in terms of tumor volume reduction, rescue/preservation of neurological function, and limited ARE evolvement., Competing Interests: There are no conflicts of interest.
- Published
- 2019
- Full Text
- View/download PDF
35. The concept of rapid rescue radiosurgery in the acute management of critically located brain metastases: A retrospective short-term outcome analysis.
- Author
-
Sinclair G, Benmakhlouf H, Brigui M, Maeurer M, and Dodoo E
- Abstract
Background: Adaptive hypofractionated gamma knife radiosurgery has been used to treat brain metastases in the eloquent regions while limiting the risk of adverse radiation effect (ARE). Ablative responses might be achieved within days to weeks with the goal to preserve the neurological function. The application of this treatment modality in selected acute/subacute settings has been termed Rapid Rescue Radiosurgery (RRR) in our department. We report the expeditious effects of RRR during treatment and 4 weeks after treatment completion., Methods: In all, 34 patients with 40 brain metastases, each treated over a period of 7 days in three separate gamma knife radiosurgery sessions (GKRS 1-3) between November 2013 and August 2017, were retrospectively analyzed in terms of tumor volume reduction, salvage of organs at risk (OAR), and radiation induced toxicity under the period of treatment (GKRS 1-3 = one week) and at first follow-up magnetic resonance imaging (MRI) (4 weeks after GKRS 3)., Results: Mean tumor volume at GKRS 1 was 12.8 cm3. Mean peripheral doses at GKRS 1, GKRS 2, and GKRS 3 were 7.7 Gy, 8.1 Gy, and 8.4 Gy (range: 6.0-9.5 Gy) at the 35% to 50% isodose lines. In the surviving group at first follow-up ( n = 28), mean tumor volume reduction was - 10% at GKRS 3 (1 week) and - 48% four weeks after GKRS 3. There was no further clinical deterioration between GKRS 3 and first follow-up in 21 patients. Six patients died prior to first follow-up due to extracranial disease. No ARE was noticed/reported., Conclusions: In this study, RRR proved effective in terms of rapid tumor volume reduction, debulking, and preservation/rescue of neurological function., Competing Interests: There are no conflicts of interest.
- Published
- 2018
- Full Text
- View/download PDF
36. Comment on 'Origins of the changing detector response in small megavoltage photon radiation fields'.
- Author
-
Andreo P and Benmakhlouf H
- Subjects
- Monte Carlo Method, Photons
- Abstract
A clarification is made with regard to the erroneous statement that assigns an incorrect conclusion to a paper by Andreo and Benmakhlouf (2017 Phys. Med. Biol. 62 1518-32) and in relation to other comments on that work. It is also argued that the Monte Carlo calculations made by the authors are based on physically incorrect input data for the fictitious materials used in their simulations, as density-effect corrections and stopping powers must correspond to the specific properties assigned to the fictitious material. Hence, their conclusions remain to be demonstrated using reliable input datasets.
- Published
- 2018
- Full Text
- View/download PDF
37. Development of a PMMA phantom as a practical alternative for quality control of gamma knife® dosimetry.
- Author
-
Chung JP, Seong YM, Kim TY, Choi Y, Kim TH, Choi HJ, Min CH, Benmakhlouf H, Chun KJ, and Chung HT
- Subjects
- Algorithms, Equipment Design, Humans, Radiosurgery instrumentation, Water, Film Dosimetry, Phantoms, Imaging, Polymethyl Methacrylate, Quality Control, Radiosurgery standards
- Abstract
Background: To measure the absorbed dose rate to water and penumbra of a Gamma Knife® (GK) using a polymethyl metacrylate (PMMA) phantom., Methods: A multi-purpose PMMA phantom was developed to measure the absorbed dose rate to water and the dose distribution of a GK. The phantom consists of a hemispherical outer phantom, one exchangeable cylindrical chamber-hosting inner phantom, and two film-hosting inner phantoms. The radius of the phantom was determined considering the electron density of the PMMA such that it corresponds to 8 g/cm
2 water depth, which is the reference depth of the absorbed dose measurement of GK. The absorbed dose rate to water was measured with a PTW TN31010 chamber, and the dose distributions were measured with radiochromic films at the calibration center of a patient positioning system of a GK Perfexion. A spherical water-filled phantom with the same water equivalent depth was constructed as a reference phantom. The dose rate to water and dose distributions at the center of a circular field delimited by a 16-mm collimator were measured with the PMMA phantom at six GK Perfexion sites., Results: The radius of the PMMA phantom was determined to be 6.93 cm, corresponding to equivalent water depth of 8 g/cm2 . The absorbed dose rate to water was measured with the PMMA phantom, the spherical water-filled phantom and a commercial solid water phantom. The measured dose rate with the PMMA phantom was 1.2% and 1.8% higher than those measured with the spherical water-filled phantom and the solid water phantom, respectively. These differences can be explained by the scattered photon contribution of PMMA off incoming60 Co gamma-rays to the dose rate. The average full width half maximum and penumbra values measured with the PMMA phantom showed reasonable agreement with two calculated values, one at the center of the PMMA phantom (LGP6.93) and other at the center of a water sphere with a radius of 8 cm (LGP8.0) given by Leksell Gamma Plan using the TMR10 algorithm., Conclusions: A PMMA phantom constructed in this study to measure the absorbed dose rates to water and dose distributions of a GK represents an acceptable and practical alternative for GK dosimetry considering its cost-effectiveness and ease of handling.- Published
- 2018
- Full Text
- View/download PDF
38. Beneficial and harmful effects of cyclodextrin-vitamin E complex on cryopreserved ram sperm.
- Author
-
Benhenia K, Rahab H, Smadi MA, Benmakhlouf H, Lamara A, Idres T, and Iguer-Ouada M
- Subjects
- Acrosome Reaction, Animals, Cell Membrane, Cell Survival drug effects, Cryoprotective Agents chemistry, Cryoprotective Agents pharmacology, Cyclodextrins chemistry, Lipid Peroxidation, Cryopreservation veterinary, Cyclodextrins pharmacology, Semen Preservation veterinary, Sheep, Sperm Motility drug effects, beta-Cyclodextrins chemistry
- Abstract
Vitamin E is a potent molecule, especially when loaded in cyclodextrin, in modulating oxidative stress during the freeze-thawing process. The present study aimed to investigate the effect of different concentrations of cyclodextrin-vitamin E complex (CD-Vit E) on cryopreserved ram sperm. Ejaculates collected from five adult rams were pooled and divided into four aliquots. All aliquots were treated in Tris-extender (Tris-glucose-citric acid) containing 2 mg cholesterol-loaded methyl-β- cyclodextrin/120 × 10
6 spermatozoa and either 0 (Control), 2, 4 or 6 mg CD-Vit E/120 × 106 spermatozoa, corresponding to 0, 0.5, 1 or 1.5 of pure vitamin E, respectively. After incubation at 22 °C for 15 min and the addition of Tris-extender containing glycerol and egg yolk (v/v), all aliquots were frozen in liquid nitrogen. After thawing, motility (computer aided sperm analysis), viability (eosin staining), membrane integrity (HOST), acrosome integrity (Coomassie G-250 staining) and lipid peroxidation (Thiobarbituric acid assay) were evaluated. Compared to control, 2 mg CD-Vit E had a significant positive effect on total motility, progressive motility, movement linearity (LIN%), viability and lipid peroxidation. At 4 mg, however, CD-Vit E had a significant negative effect on total motility, progressive motility, membrane functionality and acrosome integrity. At a greater concentration (6 mg), the negative effects were greater as compared with inclusion of 4 mg in the cryoprotectant and the percentage of rapidly and moderately motile gametes and viability were also altered. In conclusion, the effect of CD-Vit E on cryopreserved ram sperm was concentration-dependent with the 2 mg amount having a beneficial effect while greater concentrations (4 and 6 mg) had a harmful effect on sperm motility and gamete integrity but without affecting oxidative stress status., (Copyright © 2018 Elsevier B.V. All rights reserved.)- Published
- 2018
- Full Text
- View/download PDF
39. Determination of kQmsr,Q0fmsr,fref factors for ion chambers used in the calibration of Leksell Gamma Knife Perfexion model using EGSnrc and PENELOPE Monte Carlo codes.
- Author
-
Mirzakhanian L, Benmakhlouf H, Tessier F, and Seuntjens J
- Subjects
- Calibration, Electrons, Phantoms, Imaging, Uncertainty, Models, Theoretical, Monte Carlo Method, Radiometry instrumentation
- Abstract
Purpose: To calculate the kQmsr,Q0fmsr,fref factors for nine common ionization chamber types following the small fields dosimetry formalism for the calibration of the Leksell Gamma Knife
® (LGK) PerfexionTM using Monte Carlo simulation. This study also provides the first independent comparison of EGSnrc and PENELOPE for the calculation of kQmsr,Q0fmsr,fref correction factors and proposes a practical method to predict these factors based on chamber type, chamber orientation and phantom electron density., Methods: The ionization chambers are modeled using the EGSnrc and PENELOPE Monte Carlo codes based on the blueprints provided by the manufacturers. The chambers are placed in a half-sphere water phantom and five spherical phantoms made of liquid water, solid water, ABS, polystyrene, and PMMA, respectively. Dose averaged over the air cavity of the chambers and a small water volume are calculated using EGSnrc and PENELOPE Monte Carlo codes for both conventional and machine specific reference (msr) setups. Using the calculated dose ratio, the kQmsr,Q0fmsr,fref factor is determined for all phantom materials and two possible orientations of chamber. The calculated kQmsr,Q0fmsr,fref factors are compared to a previous Monte Carlo study. A relationship between the kQmsr,Q0fmsr,fref factor and the electron density of the phantom material is derived to predict the kQmsr,Q0fmsr,fref factor for any phantom material type. Applying the calculated kQmsr,Q0fmsr,fref factors to the measured dose rate of a recent round robin study improves consistency of reference dosimetry of the Leksell Gamma Knife® (LGK) PerfexionTM ., Results: Agreement within uncertainty is observed between kQmsr,Q0fmsr,fref values determined in this study and the previous PEGASOS/PENELOPE study in a liquid water phantom. The difference between kQmsr,Q0fmsr,fref values in parallel and perpendicular detector orientations is most significant for the PTW 31010 (1.8%) chamber. The percentage root-mean-square (%RMS) deviation between EGSnrc and PENELOPE calculated kQmsr,Q0fmsr,fref values for Exradin-A1SL, A14 and A14SL chambers studies in this work was found to be 0.4%. The kQmsr,Q0fmsr,fref values increase linearly with electron density of the phantom material for all chamber types mainly due to the linear dependency of photon energy fluence ratios on electron density. The average percentage difference between the calculated and predicted kQmsr,Q0fmsr,fref values using two methods is found to be 0.15% and 0.16%. Previously measured dose rates corrected with the kQmsr,Q0fmsr,fref values determined in this work leads to absorbed dose values consistent to within 0.8%., Conclusions: The calculated kQmsr,Q0fmsr,fref values in this work will enable users to apply the appropriate correction for their own specific phantom material only knowing the electron density of the phantom material., (© 2018 American Association of Physicists in Medicine.)- Published
- 2018
- Full Text
- View/download PDF
40. Gamma knife radiosurgery in the management of endolymphatic sac tumors.
- Author
-
Sinclair G, Al-Saffar Y, Brigui M, Martin H, Bystam J, Benmakhlouf H, Shamikh A, and Dodoo E
- Abstract
Background: Although widely regarded as rare epithelial tumors with a low grade of malignancy, endolymphatic sac tumors (ELST) often lead to disabling petrous bone destruction and significantly impairing symptoms at the time of primary diagnosis and/or recurrence. ELST is not uncommon in von Hippel Lindau (VHL) patients. Although open surgery is regarded as the best treatment option, recurrence remains a challenge, particularly when gross tumor resection (GTR) is deemed unachievable due to topographic conditions. Tumor recurrence successfully treated with fractionated radiotherapy and radiosurgery have been reported in selected cases. We present the case of a patient with recurrent ELST treated with salvage gamma knife radiosurgery (GKRS) adding a review of current literature., Case Description: A 65-year-old patient underwent GKRS of an unresectable, recurrent ELST. Tumor volumetric analysis showed almost 15% increase in tumor volume in the 4 months between the pre-GKRS magnetic resonance imaging (MRI) and the stereotactic MRI (s-MRI) at treatment. Follow-up MRI at 12 and 20 months showed significant decrease in local tumor volume, decreased contrast enhancement and no perifocal edema. The patient's general and neurological status remains stable to the present day., Conclusion: In the present case, GKRS was effective in the management of a recurrent ELST over the course of 20 months. Because of ELSTs recurrence potential, long-term follow up is required. The present case as well as previous reports might suggest a possible salvage/adjunctive role of radiosurgery in the management of ELST. Further studies are deemed necessary., Competing Interests: There are no conflicts of interest.
- Published
- 2018
- Full Text
- View/download PDF
41. Suitability of microDiamond detectors for the determination of absorbed dose to water around high-dose-rate 192 Ir brachytherapy sources.
- Author
-
Kaveckyte V, Malusek A, Benmakhlouf H, Alm Carlsson G, and Carlsson Tedgren Å
- Subjects
- Calibration, Cobalt therapeutic use, Computer Simulation, Monte Carlo Method, Phantoms, Imaging, Radiation Dosage, Water, Brachytherapy instrumentation, Iridium Radioisotopes therapeutic use, Radiation Dosimeters, Radiometry instrumentation
- Abstract
Purpose: Experimental dosimetry of high-dose-rate (HDR)
192 Ir brachytherapy (BT) sources is complicated due to high dose and dose-rate gradients, and softening of photon energy spectrum with depth. A single crystal synthetic diamond detector microDiamond (PTW 60019, Freiburg, Germany) has a small active volume, high sensitivity, direct readout, and nearly water-equivalent active volume. The purpose of this study was to evaluate the suitability of microDiamond detectors for the determination of absorbed dose to water around HDR192 Ir BT sources. Three microDiamond detectors were used, allowing for the comparison of their properties., Methods: In-phantom measurements were performed using microSelectron and VariSource iX HDR192 Ir BT treatment units. Their treatment planning systems (TPSs), Oncentra (v. 4.3) and BrachyVision (v. 13.6), respectively, were used to create irradiation plans for a cubic PMMA phantom with the microDiamond positioned at one of three source-to-detector distances (SDDs) (1.5, 2.5, and 5.5 cm) at a time. The source was stepped in increments of 0.5 cm over a total length of 6 cm to yield absorbed dose of 2 Gy at the nominal reference-point of the detector. Detectors were calibrated in60 Co beam in terms of absorbed dose to water, and Monte Carlo (MC) calculated beam quality correction factors were applied to account for absorbed-dose energy dependence. Phantom correction factors were applied to account for differences in dimensions between the measurement phantom and a water phantom used for absorbed dose calculations made with a TPS. The same measurements were made with all three of the detectors. Additionally, dose-rate dependence and stability of the detectors were evaluated in60 Co beam., Results: The percentage differences between experimentally determined and TPS-calculated absorbed doses to water were from -1.3% to +2.9%. The values agreed to within experimental uncertainties, which were from 1.9% to 4.3% (k = 2) depending on the detector, SDD and treatment delivery unit. No dose-rate or intrinsic energy dependence corrections were applied. All microDiamonds were comparable in terms of preirradiation dose, stability of the readings and energy response, and showed a good agreement., Conclusions: The results indicate that the microDiamond is potentially suitable for the determination of absorbed dose to water around HDR192 Ir BT sources and may be used for independent verification of TPS's calculations, as well as for QA measurements of HDR192 Ir BT treatment delivery units at clinical sites., (© 2017 American Association of Physicists in Medicine.)- Published
- 2018
- Full Text
- View/download PDF
42. Adaptive hypofractionated gamma knife radiosurgery in the acute management of large thymic carcinoma brain metastases.
- Author
-
Sinclair G, Martin H, Fagerlund M, Samadi A, Benmakhlouf H, and Doodo E
- Abstract
Background: Brain metastases often lead to serious neurological impairment and life threatening states. Their acute management remains complex, particularly in the case of rare malignancies with aggressive evolution. In large single lesions, open surgery followed by radiation to the surgical cavity is widely regarded as the best approach; yet in many cases, microsurgery is not feasible due to the lesion's critical location and/or the number of brain metastases present. We report the effects of adaptive hypofractionated gamma knife radiosurgery in the acute management of critically located thymic carcinoma metastases., Case Description: A 50-year-old male with metastatic thymic carcinoma was treated with radiosurgery for two large supratentorial brain metastases (M3 and M4) adjacent to eloquent areas and one smaller cerebellar metastasis (M2). M3 and M4 were treated with adaptive hypofractionated gamma knife radiosurgery, showing a dramatic volume reduction 4 weeks after treatment completion without radiation-induced side effects. Thirteen months later, two new small, threatening supratentorial lesions (M5-M6) were treated with the same technique. Interestingly, M2 (treated with standard single fraction) and M5-M6 developed local adverse radiation events. The patient's general and neurological status remained next to normal by the time of paper submission., Conclusion: The application of adaptive hypofractionated radiosurgery in this acute setting proved effective in terms of rapid tumor ablation, with salvage of neurological functionality and limited toxicity. We have called the overall procedure rapid rescue radiosurgery (RRR). A systematic study of past and ongoing RRR-treatments is warranted and in progress., Competing Interests: There are no conflicts of interest.
- Published
- 2017
- Full Text
- View/download PDF
43. Role of the density, density effect and mean excitation energy in solid-state detectors for small photon fields.
- Author
-
Andreo P and Benmakhlouf H
- Subjects
- Monte Carlo Method, Radiometry instrumentation, Radiometry methods, Photons, Radiation Dosimeters standards
- Abstract
A number of recent publications on small photon beam dosimetry aim at contributing to the understanding of the response of solid-state detectors in small fields. Some of them assign the difference in response to the mass density, or to the electron density, of the sensitive detector material relative to that of water. This work analyses the role of the mass and electron density ([Formula: see text]), density effect (δ) and mean excitation energy (I-value) of some detector materials in a 6 MV photon beam of 0.5 cm radius, its rationale being that the response of a detector depends critically on the stopping-power ratio detector-to-water. The influence on the detector response of volume scaling by electron density, and of electron single and multiple scattering, is also investigated. Detector materials are water, diamond and silicon, and additional materials are included for consistency in the analysis. A detailed analysis on the ([Formula: see text]) dependence of stopping-power ratios shows that the density effect δ depends both on the electron density and on the I-value of the medium, but not on the mass density ρ alone as is usually assumed. This leads to a double dependence of stopping-power ratios on the I-value and questions the adequacy of a 'density perturbation factor' or of common interpretations of detector response in terms of ρ alone. Differences in response can be described in terms of the variation of stopping power ratios detector-to-water, mainly due to different I-values and to a lesser extent to different values of electron density. It is found that at low energies the trend of Monte Carlo-calculated electron fluence spectra inside the detector materials depends solely on their I-values. No dependence on mass density or density effect alone is observed at any energy. The trend of restricted-cema ratios to water (as a substitute of absorbed dose ratios) follows that of stopping-power ratios at 1 MeV, the most probable energy of differential restricted-cema distributions in this study. It is concluded that the combined effect of the I-value and the dependence of δ on [Formula: see text] governs the restricted-cema values, and that neither ρ or a [Formula: see text] alone explain the different response of diverse detector materials. The results show that, for the small non-scaled and scaled volumes in this work, [Formula: see text] is practically constant and that in both cases the contribution of electron scattering to the restricted-cema values is about 2%.
- Published
- 2017
- Full Text
- View/download PDF
44. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry.
- Author
-
Benmakhlouf H and Andreo P
- Subjects
- Electrons, Monte Carlo Method, Photons, Spectrum Analysis, Radiometry methods
- Abstract
Purpose: Correction factors for the relative dosimetry of narrow megavoltage photon beams have recently been determined in several publications. These corrections are required because of the several small-field effects generally thought to be caused by the lack of lateral charged particle equilibrium (LCPE) in narrow beams. Correction factors for relative dosimetry are ultimately necessary to account for the fluence perturbation caused by the detector. For most small field detectors the perturbation depends on field size, resulting in large correction factors when the field size is decreased. In this work, electron and photon fluence differential in energy will be calculated within the radiation sensitive volume of a number of small field detectors for 6 MV linear accelerator beams. The calculated electron spectra will be used to determine electron fluence perturbation as a function of field size and its implication on small field dosimetry analyzed., Methods: Fluence spectra were calculated with the user code PenEasy, based on the PENELOPE Monte Carlo system. The detectors simulated were one liquid ionization chamber, two air ionization chambers, one diamond detector, and six silicon diodes, all manufactured either by PTW or IBA. The spectra were calculated for broad (10 cm × 10 cm) and narrow (0.5 cm × 0.5 cm) photon beams in order to investigate the field size influence on the fluence spectra and its resulting perturbation. The photon fluence spectra were used to analyze the impact of absorption and generation of photons. These will have a direct influence on the electrons generated in the detector radiation sensitive volume. The electron fluence spectra were used to quantify the perturbation effects and their relation to output correction factors., Results: The photon fluence spectra obtained for all detectors were similar to the spectrum in water except for the shielded silicon diodes. The photon fluence in the latter group was strongly influenced, mostly in the low-energy region, by photoabsorption in the high-Z shielding material. For the ionization chambers and the diamond detector, the electron fluence spectra were found to be similar to that in water, for both field sizes. In contrast, electron spectra in the silicon diodes were much higher than that in water for both field sizes. The estimated perturbations of the fluence spectra for the silicon diodes were 11-21% for the large fields and 14-27% for the small fields. These perturbations are related to the atomic number, density and mean excitation energy (I-value) of silicon, as well as to the influence of the "extracameral"' components surrounding the detector sensitive volume. For most detectors the fluence perturbation was also found to increase when the field size was decreased, in consistency with the increased small-field effects observed for the smallest field sizes., Conclusions: The present work improves the understanding of small-field effects by relating output correction factors to spectral fluence perturbations in small field detectors. It is shown that the main reasons for the well-known small-field effects in silicon diodes are the high-Z and density of the "extracameral" detector components and the high I-value of silicon relative to that of water and diamond. Compared to these parameters, the density and atomic number of the radiation sensitive volume material play a less significant role., (© 2016 American Association of Physicists in Medicine.)
- Published
- 2017
- Full Text
- View/download PDF
45. On the Monte Carlo simulation of small-field micro-diamond detectors for megavoltage photon dosimetry.
- Author
-
Andreo P, Palmans H, Marteinsdóttir M, Benmakhlouf H, and Carlsson-Tedgren Å
- Subjects
- Diamond, Monte Carlo Method, Radiometry instrumentation, Photons therapeutic use, Radiometry methods
- Abstract
Monte Carlo (MC) calculated detector-specific output correction factors for small photon beam dosimetry are commonly used in clinical practice. The technique, with a geometry description based on manufacturer blueprints, offers certain advantages over experimentally determined values but is not free of weaknesses. Independent MC calculations of output correction factors for a PTW-60019 micro-diamond detector were made using the EGSnrc and PENELOPE systems. Compared with published experimental data the MC results showed substantial disagreement for the smallest field size simulated ([Formula: see text] mm). To explain the difference between the two datasets, a detector was imaged with x rays searching for possible anomalies in the detector construction or details not included in the blueprints. A discrepancy between the dimension stated in the blueprints for the active detector area and that estimated from the electrical contact seen in the x-ray image was observed. Calculations were repeated using the estimate of a smaller volume, leading to results in excellent agreement with the experimental data. MC users should become aware of the potential differences between the design blueprints of a detector and its manufacturer production, as they may differ substantially. The constraint is applicable to the simulation of any detector type. Comparison with experimental data should be used to reveal geometrical inconsistencies and details not included in technical drawings, in addition to the well-known QA procedure of detector x-ray imaging.
- Published
- 2016
- Full Text
- View/download PDF
46. Implication of using MRI co-registered with CT in Leksell Gamma Knife(®) dose planning for patients with vestibular schwannoma.
- Author
-
Wangerid T, Benmakhlouf H, Grane P, Bartek J Jr, Svensson M, and Förander P
- Subjects
- Adult, Algorithms, Humans, Middle Aged, Magnetic Resonance Imaging methods, Neuroma, Acoustic surgery, Radiosurgery, Radiotherapy Planning, Computer-Assisted, Tomography, X-Ray Computed methods
- Published
- 2015
- Full Text
- View/download PDF
47. Increased survival using delayed gamma knife radiosurgery for recurrent high-grade glioma: a feasibility study.
- Author
-
Dodoo E, Huffmann B, Peredo I, Grinaker H, Sinclair G, Machinis T, Enger PO, Skeie BS, Pedersen PH, Ohlsson M, Orrego A, Kraepelien T, Barsoum P, Benmakhlouf H, Herrman L, Svensson M, and Lippitz B
- Subjects
- Adolescent, Adult, Aged, Aged, 80 and over, Brain Neoplasms pathology, Brain Neoplasms therapy, Chemoradiotherapy, Feasibility Studies, Female, Follow-Up Studies, Glioma pathology, Glioma therapy, Humans, Karnofsky Performance Status, Male, Middle Aged, Neoplasm Grading, Neoplasm Recurrence, Local mortality, Neoplasm Recurrence, Local therapy, Prospective Studies, Radiosurgery methods, Survival Analysis, Young Adult, Brain Neoplasms surgery, Glioma surgery, Neoplasm Recurrence, Local surgery, Radiosurgery mortality
- Abstract
Objective: The current study retrospectively assessed delayed gamma knife radiosurgery (GKRS) in the management of high-grade glioma recurrences., Methods: A total of 55 consecutive patients with high-grade glioma comprising 68 World Health Organization (WHO) III and WHO IV were treated with GKRS for local recurrences between 2001 and 2007. All patients had undergone microsurgery and radiochemotherapy, considered as standard therapy for high-grade glioma. Complete follow-up was available in all patients; median follow-up was 17.2 months (2.5-114.2 months). Median tumor volume was 5.2 mL, prescription dose was 20 Gy (14-22 Gy), and median max dose was 45 Gy (30-77.3 Gy)., Results: The patients with WHO III tumors showed a median survival of 49.6 months with and a 2-year survival of 90%. After GKRS of the recurrences, these patients showed a median survival of 24.2 months and a 2-year survival of 50%. The patients with WHO IV tumors had a median survival of 24.5 months with a 2-year survival of 51.4%. After the recurrence was treated with GKRS, the median survival was 11.3 months and a 2-year survival: 22.9% for the WHO IV patients., Conclusion: The current study shows a survival benefit for high-grade glioma recurrences when GKRS was administered after standard therapy. This is a relevant improvement compared with earlier studies that had had not been able to provide a beneficial effect timing radiosurgery in close vicinity to EBRT., (Copyright © 2014 Elsevier Inc. All rights reserved.)
- Published
- 2014
- Full Text
- View/download PDF
48. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
- Author
-
Benmakhlouf H, Sempau J, and Andreo P
- Subjects
- Diamond, Radiometry, Silicon, Uncertainty, Monte Carlo Method, Photons therapeutic use, Radiotherapy Planning, Computer-Assisted methods
- Abstract
Purpose: To determine detector-specific output correction factors,[Formula: see text], in 6 MV small photon beams for air and liquid ionization chambers, silicon diodes, and diamond detectors from two manufacturers., Methods: Field output factors, defined according to the international formalism published byAlfonso et al. [Med. Phys. 35, 5179-5186 (2008)], relate the dosimetry of small photon beams to that of the machine-specific reference field; they include a correction to measured ratios of detector readings, conventionally used as output factors in broad beams. Output correction factors were calculated with the PENELOPE Monte Carlo (MC) system with a statistical uncertainty (type-A) of 0.15% or lower. The geometries of the detectors were coded using blueprints provided by the manufacturers, and phase-space files for field sizes between 0.5 × 0.5 cm(2) and 10 × 10 cm(2) from a Varian Clinac iX 6 MV linac used as sources. The output correction factors were determined scoring the absorbed dose within a detector and to a small water volume in the absence of the detector, both at a depth of 10 cm, for each small field and for the reference beam of 10 × 10 cm(2)., Results: The Monte Carlo calculated output correction factors for the liquid ionization chamber and the diamond detector were within about ± 1% of unity even for the smallest field sizes. Corrections were found to be significant for small air ionization chambers due to their cavity dimensions, as expected. The correction factors for silicon diodes varied with the detector type (shielded or unshielded), confirming the findings by other authors; different corrections for the detectors from the two manufacturers were obtained. The differences in the calculated factors for the various detectors were analyzed thoroughly and whenever possible the results were compared to published data, often calculated for different accelerators and using the EGSnrc MC system. The differences were used to estimate a type-B uncertainty for the correction factors. Together with the type-A uncertainty from the Monte Carlo calculations, an estimation of the combined standard uncertainty was made, assigned to the mean correction factors from various estimates., Conclusions: The present work provides a consistent and specific set of data for the output correction factors of a broad set of detectors in a Varian Clinac iX 6 MV accelerator and contributes to improving the understanding of the physics of small photon beams. The correction factors cannot in general be neglected for any detector and, as expected, their magnitude increases with decreasing field size. Due to the reduced number of clinical accelerator types currently available, it is suggested that detector output correction factors be given specifically for linac models and field sizes, rather than for a beam quality specifier that necessarily varies with the accelerator type and field size due to the different electron spot dimensions and photon collimation systems used by each accelerator model., (© 2014 American Association of Physicists in Medicine.)
- Published
- 2014
- Full Text
- View/download PDF
49. Influence of phantom thickness and material on the backscatter factors for diagnostic x-ray beam dosimetry.
- Author
-
Benmakhlouf H, Fransson A, and Andreo P
- Subjects
- Phantoms, Imaging, Polymethyl Methacrylate, Radiometry instrumentation, Scattering, Radiation, Tomography, X-Ray Computed instrumentation
- Abstract
Most of the existing backscatter factors for the dosimetry of clinical diagnostic x-ray beams have been calculated for 15 cm thick phantoms; these data are used for skin dose determinations which in general ignore the influence of phantom material and thickness. The former should strictly be required whenever dosimetry measurements are made on phantom materials different from those used for the backscatter factor calculations. The phantom or patient thickness is of special importance when skin dose determinations are made for infants or paediatric patients. In this work, the recently published formalism for reference dosimetry and comprehensive database of backscatter factors for clinical beams and water phantoms have been extended using two correction factors which account for phantom material and thickness. These were determined with simulations using the PENELOPE Monte Carlo system, for PMMA to analyse the influence of the phantom material relative to water, and for a broad range of thicknesses of water and PMMA to investigate the role of this parameter in patient dose estimates. The material correction factor was found to be in the range 3-10%, depending on the field size and the HVL. The thickness correction factor was in the range 2-12% for a 5 cm thick phantom and square field sizes between 5 and 35 cm, reaching a plateau of about ±1% for thicknesses beyond 13 cm. Expressions in the form of surface fits over the calculated data are provided which streamline the determination of backscatter factors for arbitrary thicknesses and phantom materials, as well as field sizes. Results demonstrate the inadequacy of using conventional backscatter factors (calculated for 15 cm thick phantoms) without correction factors that take into account the phantom material and its thickness.
- Published
- 2013
- Full Text
- View/download PDF
50. Backscatter factors and mass energy-absorption coefficient ratios for diagnostic radiology dosimetry.
- Author
-
Benmakhlouf H, Bouchard H, Fransson A, and Andreo P
- Subjects
- Absorption, Algorithms, Computer Simulation, Humans, Monte Carlo Method, Phantoms, Imaging, Photons, Radiotherapy Dosage, User-Computer Interface, X-Rays, Radiometry methods, Radiotherapy Planning, Computer-Assisted methods, Scattering, Radiation
- Abstract
Backscatter factors, B, and mass energy-absorption coefficient ratios, (μ(en)/ρ)(w, air), for the determination of the surface dose in diagnostic radiology were calculated using Monte Carlo simulations. The main purpose was to extend the range of available data to qualities used in modern x-ray techniques, particularly for interventional radiology. A comprehensive database for mono-energetic photons between 4 and 150 keV and different field sizes was created for a 15 cm thick water phantom. Backscattered spectra were calculated with the PENELOPE Monte Carlo system, scoring track-length fluence differential in energy with negligible statistical uncertainty; using the Monte Carlo computed spectra, B factors and (μ(en)/ρ)(w, air) were then calculated numerically for each energy. Weighted averaging procedures were subsequently used to convolve incident clinical spectra with mono-energetic data. The method was benchmarked against full Monte Carlo calculations of incident clinical spectra obtaining differences within 0.3-0.6%. The technique used enables the calculation of B and (μ(en)/ρ)(w, air) for any incident spectrum without further time-consuming Monte Carlo simulations. The adequacy of the extended dosimetry data to a broader range of clinical qualities than those currently available, while keeping consistency with existing data, was confirmed through detailed comparisons. Mono-energetic and spectra-averaged values were compared with published data, including those in ICRU Report 74 and IAEA TRS-457, finding average differences of 0.6%. Results are provided in comprehensive tables appropriated for clinical use. Additional qualities can easily be calculated using a designed GUI interface in conjunction with software to generate incident photon spectra.
- Published
- 2011
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.