4 results on '"Caccavo VP"'
Search Results
2. Left atrial strain is a good predictor of atrio-ventricular synchrony in leadless pacemaker pacing.
- Author
-
Troisi F, Caccavo VP, Santobuono VE, Sgarra L, Carella MC, Basile P, Guaricci AI, and Grimaldi M
- Subjects
- Male, Humans, Heart Ventricles, Echocardiography, Arrhythmias, Cardiac, Heart Atria diagnostic imaging, Pacemaker, Artificial
- Abstract
Introduction: The importance of atrio-ventricular synchrony pacing in sinus rhythm patients is known. To identify patients in whom leadless pacemakers are able to guarantee this atrio-ventricular synchrony, we explored correlations among echocardiographic measures of left atrial (LA) size and function (doppler parameter and strain) with A4 amplitude in patients implanted with new generation Micra-AV device., Methods: After implantation with Micra-AV system, patients underwent device interrogation to evaluate AV synchrony based on the sensing of atrial mechanics and echocardiographic exam to assess LA morphology and LA function., Results: In the 21 studied patients (14 males, 72 ± 13 years), the A4 wave amplitude values inversely correlated with LA antero-posterior diameter, LA volume, LA contraction strain and LA conduit strain, while they were positively related with LA reservoir strain., Discussion: Our results indicate a statistically significant relationship between morphological echocardiographic LA parameters and atrial contraction signal (A4), detected by leadless pacemakers and used to synchronize ventricular pacing with the atrium. Instantaneous LA function assessment obtained with LA strain provides incremental information over morphological parameters. LA strain evaluates atrial myocardial deformation during the whole cardiac cycle. We found higher value of A4 in patients that have grater absolute value of LAsr, LAscd and LAsct, that are simple and measurable parameters of LA functional capacity., Conclusion: Preimplant echocardiographic evaluation of the atrial contractility may be useful in predicting adequate A4 sensing and consequently a good atrio-ventricular synchrony pacing. Echocardiography LA strain study seems promising in Micra-AV patient selection., (© 2023 Wiley Periodicals LLC.)
- Published
- 2024
- Full Text
- View/download PDF
3. REducing INFectiOns thRough Cardiac device Envelope: insight from real world data. The REINFORCE project.
- Author
-
Ziacchi M, Biffi M, Iacopino S, di Silvestro M, Marchese P, Miscio F, Caccavo VP, Zanotto G, Tomasi L, Dello Russo A, Donazzan L, and Boriani G
- Subjects
- Humans, Anti-Bacterial Agents therapeutic use, Causality, Defibrillators, Implantable adverse effects, Pacemaker, Artificial adverse effects, Heart Diseases complications, Prosthesis-Related Infections diagnosis, Prosthesis-Related Infections epidemiology, Prosthesis-Related Infections prevention & control
- Abstract
Aims: Infections resulting from cardiac implantable electronic device (CIED) implantation are severely impacting on patients' and on health care systems. The use of TYRXTM absorbable antibiotic-eluting envelope has proven to decrease major CIED infections within 12 months of CIED surgery. The aim is to evaluate the impact of the envelope use on infection-related clinical events in a real-world contemporary patient population., Methods and Results: Data on patients undergoing CIED surgery were collected prospectively by participating centers of the One Hospital ClinicalService project. Patients were divided into two groups according to whether TYRXTM absorbable antibiotic-eluting envelope was used or not. Out of 1819 patients, 872 (47.9%) were implanted with an absorbable antibiotic-eluting envelope and included in the Envelope group and 947 (52.1%) patients who did not receive an envelope were included in the Control group. Compared to control, patients in the Envelope group had higher thrombo-embolic or hemorrhagic risk, higher BMI, lower LVEF and more comorbidities. During a mean follow-up of 1.4 years, the incidence of infection-related events was significantly higher in the control compared to the Envelope group (2.4% vs. 0.8%, P = 0.007). The five-year cumulative incidence of infection-related events was 8.1% in the control and 2.1% in the Envelope group (HR: 0.34, 95%CI: 0.14-0.80, P = 0.010)., Conclusion: In our analysis, the use of an absorbable antibiotic-eluting envelope in the general CIED population was associated with a lower risk of systemic and pocket infection., Competing Interests: Conflict of interest: MZ received speaker’s fees from Abbott, Biotronik and Boston Scientific; GB reported small speaker fees from Bayer, Boehringer Ingelheim, Boston, Daiichi Sankyo, Janssen, and Sanofi outside of the submitted work. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose., (© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology.)
- Published
- 2023
- Full Text
- View/download PDF
4. Leadless transcatheter pacemaker: Indications, implantation technique and peri-procedural patient management in the Italian clinical practice.
- Author
-
Palmisano P, Iacopino S, De Vivo S, D'Agostino C, Tomasi L, Startari U, Ziacchi M, Pisanò ECL, Santobuono VE, Caccavo VP, Sgarito G, Rillo M, Nicosia A, and Zucchelli G
- Subjects
- Equipment Design, Female, Humans, Male, Prospective Studies, Time Factors, Treatment Outcome, Pacemaker, Artificial adverse effects, Pericardial Effusion etiology
- Abstract
Background: Safety and efficacy of leadless pacemakers (L-PM) have been demonstrated in multiple clinical trials, but real-world data on patient selection, implantation technique, and peri-procedural patient management in a clinical practice setting are lacking., Methods: Consecutive patients undergoing L-PM implantation in 14 Italian centers were followed in a prospective, multicentre, observational project. Data on baseline patient characteristics, clinical indications, implantation procedure, and peri-procedural patient management were collected. The rate and nature of device-related complications were also recorded., Results: A total of 782 L-PM patients (68.4% male, 75.6 ± 12.4 years) were included in the analysis. The main patients-related reason leading to the choice of implanting a L-PM rather than a conventional PM was the high-risk of device infection (29.5% of cases). The implantation success rate was 99.2%. The median duration of the procedure was 46 min. In 90% of patients the device was implanted in the septum. Of patients on oral anticoagulant therapy (OAT) (n = 498) the implantation procedure was performed without interrupting (17.5%) or transiently interrupting OAT without heparin bridging (60.6%). During a median follow-up of 20 months major device-related complications occurred in 7 patients (0.9%): vascular access-site complications in 3 patients, device malfunction in 2 patients, pericardial effusion/cardiac tamponade in one patient, device migration in one patient., Conclusions: In the real world setting of Italian clinical practice L-PM is often reserved for patients at high-risk of infection. The implantation success rate was very high and the risk of major complications was low. Peri-procedural management of OAT was consistent with available scientific evidence., (Copyright © 2022 Elsevier B.V. All rights reserved.)
- Published
- 2022
- Full Text
- View/download PDF
Catalog