1. Does repeated autoclave sterilization cause changes in the color and fragility of fiberglass reinforced resin crowns?
- Author
-
Ebru Delikan, Seçil Çaliskan, Ahmet Çalışkan, and Canan Özdemir
- Subjects
Autoclave sterilization ,Color stability ,Failure analysis ,Fiberglass reinforced resin crowns ,Fracture resistance ,Dentistry ,RK1-715 - Abstract
Abstract Background Since the effects of sterilization on the Fiberglass Reinforced Resin Crowns (FRRCs) is not well-known the aim of current study was to evaluate the effects of autoclave sterilization on the fracture resistance, color stability, and surface composition of FRRCs. Methods A total of 48 crowns were used. The crowns were divided into three groups according to the sterilization number: no sterilization (Control Group), one sterilization (Group 1), and four sterilizations (Group 2). The microstructure of the three crowns from each group was evaluated using scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) spectroscopy. Thirteen FRRCs from each group were first used for color stability testing and then for the fracture resistance analysis. One-way analysis of variance (ANOVA), one-way repeated measures ANOVA, and paired t-tests were used in the statistical analysis. Results EDX results revealed that the weight% of surface silicon atoms in group 2 was significantly higher. Some crack lines could be observed on the SEM images. Statistically significant differences were found in color stability following the first and fourth sterilization cycles (p
- Published
- 2023
- Full Text
- View/download PDF