23 results on '"Caprili L"'
Search Results
2. MINIMALLY INVASIVE SURGERY FOR ISOLATED MITRAL VALVE DISEASE: A SINGLE CENTER 5–YEAR EXPERIENCE
- Author
-
Borrelli, E, Faragasso, E, Caprili, L, Fahim, N, Fedeli, C, Adornini, G, and Fiorani, V
- Published
- 2024
- Full Text
- View/download PDF
3. 1-year outcomes after transfemoral transcatheter or surgical aortic valve replacement: Results from the Italian OBSERVANT study
- Author
-
Tamburino, C, Barbanti, M, D'Errigo, P, Ranucci, M, Onorati, F, Covello, R, Santini, F, Rosato, S, Santoro, G, Fusco, D, Grossi, C, Seccareccia, F, Marra, S, D'Amico, M, Gaita, F, Moretti, C, De Benedictis, M, Aranzulla, T, Pistis, G, Reale, M, Bedogni, F, Brambilla, N, Ferrario, M, Ferrero, L, Vicinelli, P, Colombo, A, Chieffo, A, Ferrari, A, Inglese, L, Casilli, F, Ettori, F, Frontini, M, Antona, C, Piccaluga, E, Klugmann, S, De Marco, F, Tespili, M, Saino, A, Leonzi, O, Rizzi, A, Grisolia, E, Franceschini Grisolia, E, Isabella, G, Fraccaro, C, Bernardi, G, Bisceglia, T, Armellini, I, Vischi, M, Parodi, E, Vignali, L, Ardissimo, D, Marzocchi, A, Marrozzini, C, Cremonesi, A, Colombo, F, Giannini, C, Pierli, C, Iadanza, A, Meucci, F, Berti, S, Mariani, M, Tomai, F, Ghini, A, Violini, R, Confessore, P, Crea, F, Giubilato, S, Sardella, G, Mancone, M, Ribichini, F, Vassanelli, C, Dandale, R, Giudice, P, Vigorito, F, Liso, A, Specchia, L, Indolfi, C, Spaccarotella, C, Stabile, A, Gandolfo, C, Ussia, G, Comoglio, C, Dyrda, O, Rinaldi, M, Salizzoni, S, Micalizzi, E, Di Gregorio, O, Scoti, P, Costa, R, Casabona, R, Del Ponte, S, Panisi, P, Spira, G, Troise, G, Messina, A, Viganò, M, Aiello, M, Alfieri, O, Denti, P, Menicanti, L, Agnelli, B, Donatelli, F, Muneretto, C, Rambaldini, M, Gamba, A, Tasca, G, Ferrazzi, P, Terzi, A, Gelpi, G, Martinelli, L, Bruschi, G, Graffigna, A, Mazzucco, A, Pappalardo, A, Gatti, G, Livi, U, Pompei, E, Coppola, R, Gucciardo, M, Albertini, A, Caprili, L, Ghidoni, I, Gabbieri, D, La Marra, M, Aquino, T, Gherli, T, Policlinico, S, Di Bartolomeo, R, Savini, C, Popoff, G, Innocenti, D, Bortolotti, U, Pratali, S, Stefano, P, Blanzola, C, Glauber, M, Cerillo, A, Chiaramonti, F, Pardini, A, Fioriello, F, Torracca, L, Rescigno, G, De Paulis, R, Nardella, S, Musumeci, F, Luzi, G, Possati, G, Bonalumi, G, Covino, E, Pollari, F, Sinatra, R, Roscitano, A, Chiariello, L, Nardi, P, Lonobile, T, Baldascino, F, Di Benedetto, G, Mastrogiovanni, G, Piazza, L, Marmo, J, Vosa, C, De Amicis, V, Speziale, G, Visicchio, G, Spirito, R, Gregorini, R, Villani, M, Pano, M, Bortone, A, De Luca Tupputi Schinosa, L, De Cillis, E, Gaeta, R, Di Natale, M, Cassese, M, Antonazzo, A, Argano, V, Santaniello, E, Patanè, L, Gentile, M, Tribastone, S, Follis, F, Montalbano, G, Pilato, M, Stringi, V, Patanè, F, Salamone, G, Ruvolo, G, Pisano, C, Mignosa, C, Bivona, A, Cirio, E, Lixi, G, Maraschini, A, Badoni, G, Onorato, F, De Palma, R, Scandotto, S, Orlando, A, Copello, F, Borgia, P, Marchetta, F, and Porcu, R
- Subjects
aortic stenosis ,implantation ,intermediate risk ,transcatheter aortic valve ,Settore MED/23 - Chirurgia Cardiaca - Published
- 2015
4. New cardiac bioprostheses: the case of 'sutureless' valves
- Author
-
Albertini, A., primary, Mikus, E., additional, Sabarese, M., additional, Caprili, L., additional, Del Giglio, M., additional, and Lamarra, M., additional
- Published
- 2015
- Full Text
- View/download PDF
5. Two-step aortic cross-clamping technique for acute type-a aortic dissection in octogenarians
- Author
-
Caprili L, Amico A, and Carbone C
- Subjects
Pulmonary and Respiratory Medicine ,Male ,medicine.medical_specialty ,Extracorporeal Circulation ,Two step ,Blood Vessel Prosthesis Implantation ,medicine.artery ,Ascending aorta ,Medicine ,Humans ,Aortic dissection ,Aged, 80 and over ,Surgical approach ,Aortic Aneurysm, Thoracic ,business.industry ,Extracorporeal circulation ,High mortality ,medicine.disease ,Constriction ,Clamping ,Surgery ,Aortic Dissection ,Treatment Outcome ,Acute type ,Acute Disease ,cardiovascular system ,Female ,Stents ,Cardiology and Cardiovascular Medicine ,business - Abstract
In octogenarians, due to the high mortality and morbidity, acute type-A aortic dissection requires a less invasive surgical approach. We describe a method in which replacement of the ascending aorta and stenting of the dissected arch are performed with mild hypothermic extracorporeal circulation.
- Published
- 2008
6. Biological versus mechanical aortic prosthesis? A nineteen-year comparison in a propensity-matched population
- Author
-
TOMASO BOTTIO, Rizzoli, G., Caprili, L., Testolin, L., Thiene, G., and Gerosa, G.
- Published
- 2005
7. Full-Sternotomy Off-Pump versus On-Pump Coronary Artery Bypass Procedures: In-Hospital Outcomes and Complications during One Year in a Single Center
- Author
-
TOMASO BOTTIO, Rizzoli, G., Caprili, L., Nesseris, G., Thiene, G., and Gerosa, G.
- Subjects
Adult ,Aged, 80 and over ,Male ,Cardiopulmonary Bypass ,Coronary Artery Disease ,Middle Aged ,Postoperative Complications ,Treatment Outcome ,Editorial ,Thoracotomy ,Humans ,Female ,Hospital Mortality ,Prospective Studies ,Clinical Investigation ,Coronary Artery Bypass ,Aged ,Follow-Up Studies - Abstract
We prospectively compared, according to their preoperative clinical profiles, the in-hospital outcomes of patients operated on consecutively (but without randomization) for isolated coronary artery disease with on-pump or off-pump techniques. During 2001, 324 patients underwent coronary artery bypass grafting: 216 patients (mean age, 66.7 +/- 8.9 years; range, 41-85 years) underwent on-pump revascularization, and 108 patients (mean age, 676 +/- 10 years; range, 37-90 years) underwent full-sternotomy off-pump revascularization. The 2 groups were homogeneous with regard to female sex (22.6% vs 26.8%), previous cardiac operation (2.8% vs 4.6%), cardiogenic shock (1.3% vs 1.9%), diabetes (30% vs 33%), and chronic renal failure that required hemodialysis (3% vs 3.5%). Postoperative complications, including bleeding, myocardial infarction, acute renal failure, mediastinitis with sternal dehiscence, cerebrovascular events, and prolonged respiratory assistance were more frequent in on-pump patients (P = 0.004). The total number of grafts and the grafts per patient ratio were significantly higher in on-pump patients (P = 0.0001), whereas the total number of full arterial revascularizations was higher in off-pump patients (P = 0.0001). Off-pump patients showed a significantly shorter intensive care unit stay (P = 0.02), and less need for intra-aortic balloon pump insertion (P = 0.04). In-hospital mortality was 2.8% in on-pump patients and 2.7% in off-pump patients (P = NS). Although the hospital mortality rate was comparable for the 2 techniques, the in-hospital comparison between the 2 groups showed how the avoidance of cardiopulmonary bypass can significantly reduce the cumulative postoperative incidence of complications in patients undergoing coronary artery bypass grafting.
- Published
- 2003
8. Two-Step Aortic Cross-Clamping Technique for Acute Type-A Aortic Dissection in Octogenarians
- Author
-
Amico, A., primary, Caprili, L., additional, and Carbone, C., additional
- Published
- 2008
- Full Text
- View/download PDF
9. Small aortic annulus: The hydrodynamic performances of 5 commercially available bileaflet mechanical valves
- Author
-
Bottio, T., primary, Caprili, L., additional, Casarotto, D., additional, and Gerosa, G., additional
- Published
- 2005
- Full Text
- View/download PDF
10. Intrapericardial Ectopic Thyroid Arising From the Ascending Aorta.
- Author
-
Carrese E, Rapicetta C, Borrelli R, Caprili L, Matricardi A, Fiorani V, and Paci M
- Subjects
- Aged, Female, Humans, Tomography, X-Ray Computed, Aorta, Pericardium, Thyroid Dysgenesis diagnosis
- Published
- 2021
- Full Text
- View/download PDF
11. Aortic valve endocarditis complicated by proximal false aneurysm.
- Author
-
Malvindi PG, Mikus E, Caprili L, Santarpino G, Margari V, Calvi S, Nasso G, Gregorini R, Carbone C, Albertini A, Speziale G, and Paparella D
- Abstract
Background: Aortic valve endocarditis remains a life-threatening condition, especially in cases of periannular complications. Aorto-ventricular discontinuity associated with proximal false aneurysm represents a severe picture caused by extensive tissue disruption and is usually associated with prosthetic valve infection. Complex surgical repair is required in these cases and continues to be associated with high mortality and morbidity rates., Methods: We retrieved information for 32 patients undergoing operation for infective aortic valve/prosthetic valve endocarditis complicated by pseudoaneurysm arising from aorto-ventricular discontinuity. Patients were relatively young, mostly male and most of them had a prior cardiac operation. Aortic root replacement with valve graft conduit was performed in all cases; it was associated with other procedures in seven patients: CABG (n=2), MV surgery (n=3), MV surgery + CABG (n=1) and pulmonary valve replacement (n=1). We reported and analysed patient outcomes at early and mid-term follow-up., Results: Pre-discharge mortality was 22% (n=7). The postoperative course was complicated in 24 (75%) cases. Eighteen patients (56%) sustained low cardiac output resulting in multiple organ failure syndrome and death in five cases. One patient (3%) experienced a major neurologic deficit with a permanent cerebral stroke. Acute kidney injury complicated the course in 12 cases (37%), continuous renal replacement therapy was necessary in four patients (12%). Overall survival and freedom from endocarditis and reoperation at 5-year was 59% and 89%, respectively., Conclusions: Patients with complicated aortic valve endocarditis presented generally in a poor preoperative state. Surgical treatment poses a non-negligible risk of postoperative mortality and morbidity but provides an acceptable survival rate and a satisfactory recovery at mid-term., Competing Interests: Conflicts of Interest: The authors have no conflicts of interest to declare., (2019 Annals of Cardiothoracic Surgery. All rights reserved.)
- Published
- 2019
- Full Text
- View/download PDF
12. Mycobacterium chimaera infections following cardiac surgery in Italy: results from a National Survey Endorsed by the Italian Society of Cardiac Surgery.
- Author
-
Cappabianca G, Paparella D, D'Onofrio A, Caprili L, Minniti G, Lanzafame M, Parolari A, Musumeci F, and Beghi C
- Subjects
- Cross Infection epidemiology, Disease Outbreaks, Humans, Italy epidemiology, Mycobacterium Infections epidemiology, Reoperation statistics & numerical data, Surveys and Questionnaires, Cardiac Surgical Procedures adverse effects, Cross Infection etiology, Equipment Contamination, Mycobacterium isolation & purification, Mycobacterium Infections etiology
- Abstract
Aims: A global outbreak of Mycobacterium chimaera infections following cardiac surgery and linked to contaminated heater-cooler units (HCUs) is currently ongoing. Neither the status of this outbreak in Italy nor the mitigation strategies adopted by adult cardiac surgery units (ACSUs) are currently known. In 2017, the Italian Society of Cardiac Surgery launched a national survey among the Italian ACSU to shed some light on this issue., Methods: In Italy, there are 90 ACSUs across 20 regions. From May to November 2017, these ACSUs were surveyed collecting data on patients diagnosed with MC infections, ACSU workload, HCU models in use and control measures adopted in the operatory room., Results: The response rate was 87.8%. The median number of cardiac procedures at each ACSU was 450/year [interquartile range (IQR) 350-650 procedures/year], and nationally, the number of procedures/year exceeded 40k. In Italy, seven patients with M. chimaera infections following cardiac procedures have been reported since 2015: all had aortic or valvular surgery as the first procedure; the median latency between the first operation and the infection was 2 years (IQR 2-3.25). Mortality for patients requiring redo cardiac surgery was 50%. M. chimaera infections risk was 0.4-1 patient every 1000 cardiac procedures. The most common HCU model in Italy is the 3T HCU (70.9%). The most common control measures adopted included implementing new HCU disinfection protocols, using sterile or filtrated water in the HCU and displacing HCU fans away from the patient: HCU replacement and microbiology testing were instead infrequent., Conclusion: In Italy, the risk of contracting M. chimaera infections and the mortality reported are in line with other European countries, but significant heterogeneity exists on the mitigation strategies adopted to prevent further M. chimaera inoculations, suggesting the development of national guidelines.
- Published
- 2018
- Full Text
- View/download PDF
13. Combined off-pump minimally invasive coronary artery bypass grafting and mitral valve repair with NeoChord via a left anterolateral small thoracotomy.
- Author
-
Albertini A, Amoncelli E, Piccinini L, and Caprili L
- Subjects
- Aged, 80 and over, Coronary Artery Disease complications, Coronary Artery Disease diagnosis, Humans, Male, Mitral Valve Insufficiency complications, Mitral Valve Insufficiency diagnosis, Treatment Outcome, Coronary Artery Bypass, Off-Pump, Coronary Artery Disease surgery, Heart Valve Prosthesis Implantation, Mitral Valve Insufficiency surgery, Thoracotomy
- Abstract
Off-pump direct coronary artery bypass grafting through a left anterior small thoracotomy is widely utilized for minimally invasive myocardial revascularization. More recently, a novel technique for transapical off-pump mitral valve repair with the NeoChord device is demonstrating its efficacy. This report describes a case of an 84-year-old male patient with coronary artery disease involving the left anterior descending coronary artery and acute severe mitral regurgitation secondary to posterior leaflet flail who underwent both off-pump coronary artery bypass and mitral valve repair with the transapical implantation of artificial chordae using the NeoChord DS 1000 system through the same anterolateral small thoracotomy.
- Published
- 2018
- Full Text
- View/download PDF
14. Coronary Artery Pseudoaneurysm After Bentall Procedure.
- Author
-
Manenti A, Zizzo M, Fedeli C, and Caprili L
- Subjects
- Aortic Aneurysm, Thoracic surgery, Heart Valve Prosthesis Implantation, Humans, Aneurysm, False surgery, Coronary Vessels surgery
- Published
- 2016
- Full Text
- View/download PDF
15. Internal Thoracic Artery Histologic Characteristics Clarify Its High Performance in Coronary Bypass.
- Author
-
Roncati L, Manenti A, Caprili L, and Fedeli R
- Subjects
- Coronary Angiography, Humans, Internal Mammary-Coronary Artery Anastomosis, Vascular Patency, Coronary Artery Bypass, Mammary Arteries transplantation
- Published
- 2016
- Full Text
- View/download PDF
16. Right anterior minithoracotomy aortic valve replacement with a sutureless bioprosthesis: Early outcomes and 1-year follow-up from 2 European centers.
- Author
-
Vola M, Albertini A, Campisi S, Caprili L, Fuzellier JF, Favre JP, Morel J, and Gerbay A
- Subjects
- Aged, Aged, 80 and over, Aortic Valve physiopathology, Aortic Valve Stenosis diagnosis, Aortic Valve Stenosis mortality, Aortic Valve Stenosis physiopathology, Cardiopulmonary Bypass, Female, Follow-Up Studies, France, Heart Valve Prosthesis Implantation adverse effects, Heart Valve Prosthesis Implantation mortality, Hemodynamics, Hospital Mortality, Humans, Italy, Male, Operative Time, Postoperative Complications mortality, Prosthesis Design, Retrospective Studies, Severity of Illness Index, Sternotomy, Time Factors, Treatment Outcome, Aortic Valve surgery, Aortic Valve Stenosis surgery, Bioprosthesis, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation instrumentation, Heart Valve Prosthesis Implantation methods, Thoracotomy adverse effects, Thoracotomy mortality
- Abstract
Background: A sutureless aortic valve can be inserted through a right anterior minithoracotomy (RAMT) with consistent decreased cross-clamping time and ease of insertion. We report the experience of RAMT implantation of the 3f Enable (Medtronic, Inc, Minneapolis, Minn) self-expanding sutureless bioprosthesis, performed in 2 European cardiac surgery centers., Method: From September 2012 to April 2014, a total of 71 patients with severe aortic stenosis were selected to receive an aortic valve replacement via RAMT using the sutureless valve. Hemodynamic parameters and clinical outcome were assessed at discharge and up to 16 months postoperatively., Results: All the patients received the prosthesis with success. One conversion to median sternotomy was necessary, owing to severe pleural adhesions. Overall in-hospital mortality was 2.8%. Mean cardiopulmonary bypass and cross-clamping time were, respectively, 91 ± 29 minutes and 66 ± 19 minutes. Reclamping was necessary in 4 cases (5.6%). Early incidences of grade I or lower paravalvular leakages and pacemaker implantation were, respectively, 4.2% and 5.6%. No paravalvular leakage greater than grade I was registered. The mean follow-up time was 8.1 months; the mean transvalvular gradient was, at discharge and at 6-12 months, respectively, 10.7 ± 4.3 mm Hg and 9.6 ± 3.1 mm Hg. The degree of regurgitation remained stable in all cases. Freedom from all-cause and valve-related mortality was 97% and 99%, respectively, at 1 year., Conclusions: Aortic valve replacement via RAMT with the 3f Enable valve is a reproducible procedure, as it provides satisfactory hemodynamics, and a low valve-related complication rate. Greater experience is needed to compare the performance of the 3f Enable valve with that of other sutureless valves implanted via the same RAMT procedure., (Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.)
- Published
- 2015
- Full Text
- View/download PDF
17. Very early malfunction of a large stentless aortic valve.
- Author
-
Caprili L, Fahim AN, Zussa C, and Cristell DM
- Subjects
- Aged, Aortic Valve Stenosis etiology, Calcinosis etiology, Female, Humans, Prosthesis Failure, Stents, Aortic Valve surgery, Heart Valve Prosthesis, Prosthesis Design
- Abstract
Since their introduction in 1990, modern stentless aortic prostheses have by now obtained wide acceptance in the treatment of aortic valve disease. Despite the favourable results of using different techniques, concerns still remain about the durability of this device, especially regarding mineralisation. We present the first report, to our knowledge, of an early and unexpected malfunction of a large Sorin Solo stentless valve due to calcification only 18 months after implantation.
- Published
- 2009
- Full Text
- View/download PDF
18. Surgical strategy for acute type A aortic dissection in octogenarian.
- Author
-
Amico A, Caprili L, Fahim NA, Cristell D, and Carbone C
- Subjects
- Acute Disease, Aged, 80 and over, Aortic Dissection diagnosis, Aortic Aneurysm, Thoracic diagnosis, Echocardiography, Transesophageal, Female, Follow-Up Studies, Humans, Polyethylene Terephthalates, Suture Techniques, Tomography, X-Ray Computed, Aortic Dissection surgery, Aortic Aneurysm, Thoracic surgery, Blood Vessel Prosthesis Implantation methods
- Abstract
With the progressive aging of Western populations, cardiac surgeons are increasingly faced with octogenarians. In these high-risk patients, owing to high mortality, the surgical strategy has to be adapted to the patient's age. We describe a method by which the cross-clamping technique is associated with a safe and simple maneuver, consisting of stenting the aortic arch and reducing the aortic cross-clamping damages.
- Published
- 2008
- Full Text
- View/download PDF
19. Biological versus mechanical aortic prosthesis? A nineteen-year comparison in a propensity-matched population.
- Author
-
Bottio T, Rizzoli G, Caprili L, Testolin L, Thiene G, and Gerosa G
- Subjects
- Adolescent, Adult, Age Factors, Aged, Blood Pressure, Follow-Up Studies, Heart Valve Diseases classification, Humans, Italy epidemiology, Liver Failure mortality, Matched-Pair Analysis, Middle Aged, Multivariate Analysis, Prospective Studies, Prosthesis Design, Prosthesis Failure, Pulmonary Artery, Reoperation statistics & numerical data, Risk Factors, Survival Analysis, Aortic Valve surgery, Bioprosthesis, Heart Valve Diseases mortality, Heart Valve Diseases surgery, Heart Valve Prosthesis
- Abstract
Background and Aim of the Study: The choice of aortic valve substitutes remains controversial. Malfunction and systemic valve complications affect the results of mechanical and tissue valves. Two devices--the Sorin Monocast (tilting disk) valve and the Hancock Standard valve were compared, the study aim being to determine whether the valve model is a marker or a causal influence of poor outcome after aortic valve replacement (AVR)., Methods: Between January 1970 and January 1984, patients aged < 70 years and operated on for aortic valve disease were selected. A total of 379 patients received either Sorin (group S) valves (n = 213; median age 51 years) or Hancock Standard (group HcK) valves (n = 192; median age 50 years) (p = NS). Total follow up was 2,471 patient-years (pt-yr) for group S and 2,368 pt-yr for group HcK. Follow up was 98% complete; median duration was 15 pt-yr for group S and 13.2 pt-yr for group HcK. Propensity matching for available patient intrinsic and operative risk factors was ultimately used to investigate whether biological or mechanical valve models impact upon outcome after aortic valve surgery. Patient survival was analyzed according to the 'intention to treat' principle., Results: The 30-day mortality was 7.5% for group S and 10.9% for group HcK (p = NS). The 19-year Kaplan-Meier freedom from valve-related mortality was 84% (group S) and 82% (group HcK) (p = NS), while overall survival was 42% (group S) and 35% (group HcK) (p = NS). Structural valve deterioration (SVD) was the major cause of reoperation in the HcK group. The 19-year freedom from all valve-related complications was 43% (group S) versus 19% (group HcK) (p = 0.0001). By propensity score, 61% of the valve replacements (247/405) were perfectly matched for available risk factors, with an equal distribution of risk covariates. When SVD and reoperation due to SVD were excluded, survival and freedom from all valve-related complications of the matched patients were identical between the prostheses under comparison., Conclusion: In this relatively young population, the Sorin valve showed a significantly lower valve-related complication rate than the Hancock Standard valve. The latter valve showed a significantly increasing rate of reoperation due to SVD, and thereby a relative inadequacy for use in younger patients. When analyzed according to an 'intention to treat' principle, the 19-year survival and freedom from valve-related complications of patients with the same propensity score for selection of either valve type were similar.
- Published
- 2005
20. Intermediate results of isolated mitral valve replacement with a Biocor porcine valve.
- Author
-
Rizzoli G, Bottio T, Vida V, Nesseris G, Caprili L, Thiene G, and Gerosa G
- Subjects
- Adult, Age Factors, Aged, Aged, 80 and over, Anticoagulants adverse effects, Echocardiography, Endocarditis etiology, Endocarditis mortality, Endocarditis surgery, Female, Follow-Up Studies, Heart Valve Diseases mortality, Heart Valve Diseases surgery, Humans, Italy, Male, Middle Aged, Mitral Valve diagnostic imaging, Postoperative Complications etiology, Postoperative Complications mortality, Postoperative Complications surgery, Postoperative Hemorrhage chemically induced, Postoperative Hemorrhage mortality, Prosthesis Design, Reoperation, Survival Analysis, Thromboembolism etiology, Thromboembolism mortality, Time Factors, Treatment Outcome, Bioprosthesis, Heart Valve Prosthesis Implantation, Mitral Valve surgery
- Abstract
Background: We analyzed the intermediate experience, survival, and prosthetic complications of patients who received the Biocor valve, a new-generation porcine valve, in the mitral position., Methods: At the University of Padua, between May 1992 and January 2004, 154 consecutive patients (102 female and 52 male patients; mean age, 72.3 +/- 6 years; age range, 37-86 years) received 158 mitral Biocor prostheses (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil). Thirty-five percent of the patients had previous mitral operations, 24% had coronary artery bypass grafting, and 34.6% had other procedures. Median preoperative New York Heart Association class was III. Echocardiography was performed in 75% of the long-term survivors. Follow-up included 609.4 patient-years and was 100% complete, with a median time of 4 patient-years (range, 0.02-11.3 years). At 8 years, 20 (14%) of 142 operative survivors were still at risk., Results: Early mortality was 13.6%. According to univariate analysis, New York Heart Association class III to IV, ejection fraction of less than 40%, urgency, male sex, and coronary artery bypass grafting were significant perioperative risk factors. Eight- and 10-year actuarial survival was 51.1% +/- 5.6% (40 deaths). Eight-year actuarial freedom from valve-related death, thromboembolism, anticoagulant-related hemorrhage, endocarditis, paravalvular leak, and valve-related complications were 85.2% +/- 5%, 85.7% +/- 4.4%, 92.6% +/- 3.7%, 94.1% +/- 3%, 91.8% +/- 3%, and 70.2% +/- 5.7%, respectively. Freedom from structural valve deterioration was 100%. Actual freedom from reoperation was 93.2% +/- 2.2%. By Doppler echocardiography, the peak and mean transprosthetic gradients were 15 +/- 5 mm Hg and 6.3 +/- 3 mm Hg, respectively (mean follow-up, 4.2 +/- 2.7 years)., Conclusion: At intermediate follow-up, the Biocor prosthesis in the mitral position showed excellent results in terms of valve durability when compared with other second-generation tissue valves.
- Published
- 2005
- Full Text
- View/download PDF
21. Small aortic annulus: the hydrodynamic performances of 5 commercially available bileaflet mechanical valves.
- Author
-
Bottio T, Caprili L, Casarotto D, and Gerosa G
- Subjects
- Biomechanical Phenomena, Prosthesis Design, Water, Aortic Valve anatomy & histology, Heart Valve Prosthesis
- Abstract
Objective: Hemodynamic performances of mechanical valve prostheses in patients with aortic valve stenosis and a small aortic annulus are crucial. We analyzed the in vitro hydrodynamics of 5 currently available bileaflet mechanical prostheses that fitted a 21-mm-diameter valve holder of a Sheffield pulse duplicator., Methods: Three samples of 5 high-performance production-quality prostheses, including the sewing ring cuffs, were tested in the aortic chamber of a Sheffield pulse duplicator. Sizes of the prostheses fitting the 21-mm valve holder were as follows: 18-mm ATS, 19-mm SJM Regent, 19-mm Sorin Bicarbon Slimline, 19-mm On-X, and 21-mm Carbomedics Top Hat. The tests were carried out at a fixed pulse rate (70 beats/min) and at increasing cardiac outputs of 2, 4, 5, and 7 L/min. Each valve was tested 10 times for each different cardiac output. This resulted in a total of 40 tests for each valve and 120 tests for each valve model. The aortic pressure was set at 120/80 mm Hg (mean pressure, 100 mm Hg) throughout the experiment for all cardiac outputs. Forward flow pressure decrease, total regurgitant volume, closing and leakage volumes, effective orifice area, and stroke work loss were recorded while the valve operated under each cardiac output., Results: The SJM Regent valve and the Sorin Bicarbon Slimline prosthesis showed the lowest mean and peak gradients at increasing cardiac outputs. The closure volume was higher for the SJM Regent and Sorin Bicarbon Slimline prostheses, unlike with the ATS prosthesis at 7 L/min of cardiac output. The ATS and SJM Regent prostheses showed the largest regurgitant volume, whereas the Sorin Bicarbon Slimline prosthesis showed the lowest regurgitant volume. The calculated effective orifice area and stroke work loss were significantly better with the SJM Regent and Sorin Bicarbon Slimline prostheses., Conclusion: Assuming that the 21-mm valve holder in which all the tested prostheses were accommodated is comparable with a defined aortic valve size, this hydrodynamic evaluation model allowed us to compare the efficiency of currently available valve prostheses, and among these, the SJM Regent and the Sorin Bicarbon Slimline exhibited the best performances.
- Published
- 2004
- Full Text
- View/download PDF
22. Leaflet escape in a new bileaflet mechanical valve: TRI technologies.
- Author
-
Bottio T, Casarotto D, Thiene G, Caprili L, Angelini A, and Gerosa G
- Subjects
- Adult, Aged, Aortic Valve surgery, Female, Heart Valve Prosthesis Implantation, Hospital Mortality, Humans, Male, Middle Aged, Mitral Valve surgery, Reoperation, Survival Analysis, Thromboembolism etiology, Heart Valve Prosthesis adverse effects
- Abstract
Background: Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis., Methods and Results: At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak., Conclusions: These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.
- Published
- 2003
- Full Text
- View/download PDF
23. Full-sternotomy off-pump versus on-pump coronary artery bypass procedures: in-hospital outcomes and complications during one year in a single center.
- Author
-
Bottio T, Rizzoli G, Caprili L, Nesseris G, Thiene G, and Gerosa G
- Subjects
- Adult, Aged, Aged, 80 and over, Coronary Artery Bypass methods, Coronary Artery Disease mortality, Coronary Artery Disease surgery, Female, Follow-Up Studies, Humans, Male, Middle Aged, Prospective Studies, Thoracotomy adverse effects, Thoracotomy methods, Thoracotomy mortality, Treatment Outcome, Cardiopulmonary Bypass adverse effects, Cardiopulmonary Bypass mortality, Coronary Artery Bypass adverse effects, Coronary Artery Bypass mortality, Hospital Mortality, Postoperative Complications
- Abstract
We prospectively compared, according to their preoperative clinical profiles, the in-hospital outcomes of patients operated on consecutively (but without randomization) for isolated coronary artery disease with on-pump or off-pump techniques. During 2001, 324 patients underwent coronary artery bypass grafting: 216 patients (mean age, 66.7 +/- 8.9 years; range, 41-85 years) underwent on-pump revascularization, and 108 patients (mean age, 676 +/- 10 years; range, 37-90 years) underwent full-sternotomy off-pump revascularization. The 2 groups were homogeneous with regard to female sex (22.6% vs 26.8%), previous cardiac operation (2.8% vs 4.6%), cardiogenic shock (1.3% vs 1.9%), diabetes (30% vs 33%), and chronic renal failure that required hemodialysis (3% vs 3.5%). Postoperative complications, including bleeding, myocardial infarction, acute renal failure, mediastinitis with sternal dehiscence, cerebrovascular events, and prolonged respiratory assistance were more frequent in on-pump patients (P = 0.004). The total number of grafts and the grafts per patient ratio were significantly higher in on-pump patients (P = 0.0001), whereas the total number of full arterial revascularizations was higher in off-pump patients (P = 0.0001). Off-pump patients showed a significantly shorter intensive care unit stay (P = 0.02), and less need for intra-aortic balloon pump insertion (P = 0.04). In-hospital mortality was 2.8% in on-pump patients and 2.7% in off-pump patients (P = NS). Although the hospital mortality rate was comparable for the 2 techniques, the in-hospital comparison between the 2 groups showed how the avoidance of cardiopulmonary bypass can significantly reduce the cumulative postoperative incidence of complications in patients undergoing coronary artery bypass grafting.
- Published
- 2003
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.