3 results on '"DC06 steel"'
Search Results
2. A novel ultrasonic strain gauge for single-sided measurement of a local 3D strain field.
- Author
-
Kersemans, Mathias, Allaer, Klaas, Van Paepegem, Wim, Van Den Abeele, Koen, Pyl, Lincy, Zastavnik, Filip, Sol, Hugo, and Degrieck, Joris
- Subjects
- *
STRAIN gages , *STRAIN rate , *DEFORMATIONS (Mechanics) , *ULTRASONIC imaging , *ULTRASONICS - Abstract
A novel method is introduced for the measurement of a 3D strain field by exploiting the interaction between ultrasound waves and geometrical characteristics of the insonified specimen. First, the response of obliquely incident harmonic waves to a deterministic surface roughness is utilized. Analysis of backscattered amplitudes in Bragg diffraction geometry then yields a measure for the in-plane strain field by mapping any shift in angular dependency. Secondly, the analysis of the reflection characteristics of normal incident pulsed waves in frequency domain provides a measure of the out-of-plane normal strain field component, simply by tracking any change in the stimulation condition for a thickness resonance. As such, the developed ultrasonic strain gauge yields an absolute, contactless and single-sided mapping of a local 3D strain field, in which both sample preparation and alignment procedure are needless. Results are presented for cold-rolled DC06 steel samples onto which skin passing of the work rolls is applied. The samples have been mechanically loaded, introducing plastic strain levels ranging from 2 % up to 35 %. The ultrasonically measured strains have been validated with various other strain measurement techniques, including manual micrometer, longitudinal and transverse mechanical extensometer and optical mono- and stereovision digital image correlation. Good agreement has been obtained between the ultrasonically determined strain values and the results of the conventional methods. As the ultrasonic strain gauge provides all three normal strain field components, it has been employed for the extraction of Lankford ratios at different applied longitudinal plastic strain levels, revealing a strain dependent plastic anisotropy of the investigated DC06 steel sheet. [ABSTRACT FROM AUTHOR]
- Published
- 2014
- Full Text
- View/download PDF
3. An ultrasonic strain gauge
- Author
-
Kersemans, M., Allaer, K., Degrieck, J., Koen Van Den Abeele, Pyl, L., Zastavnik, F., Sol, H., Paepegem, W., Jaigu, Anne, Le Cam, Vincent and Mevel, Laurent and Schoefs, Franck, Universiteit Gent = Ghent University [Belgium] (UGENT), Katholieke Universiteit Leuven Campus Kortrijk, Catholic University of Leuven - Katholieke Universiteit Leuven (KU Leuven), Vrije Universiteit Brussel (VUB), IFFSTTAR, Inria, Université de Nantes, Le Cam, Vincent and Mevel, Laurent and Schoefs, Franck, and Mechanics of Materials and Constructions
- Subjects
Stress & strain ,3D strain field ,Technology and Engineering ,[STAT.TH] Statistics [stat]/Statistics Theory [stat.TH] ,ultrasound ,Lankford parameter ,[PHYS.MECA]Physics [physics]/Mechanics [physics] ,[STAT.TH]Statistics [stat]/Statistics Theory [stat.TH] ,[SPI.MECA]Engineering Sciences [physics]/Mechanics [physics.med-ph] ,[SPI.MECA] Engineering Sciences [physics]/Mechanics [physics.med-ph] ,DC06 steel ,[MATH.MATH-ST]Mathematics [math]/Statistics [math.ST] ,[PHYS.MECA] Physics [physics]/Mechanics [physics] ,Interaction between wave/field and structure/material ,Pipelines SHM applications ,[MATH.MATH-ST] Mathematics [math]/Statistics [math.ST] - Abstract
International audience; A method is introduced for the measurements of strain exploiting the interaction between ultrasound waves and characteristics of the insonified specimen. First, the response of obliquely incident harmonic waves to a deterministic surface roughness is utilized. Analysis of backscattered amplitudes in Bragg diffraction geometry then yields a measure for the in-plane strain field by mapping any shift in angular dependency. Secondly, the analysis of the reflection characteristics of normal incidence pulsed waves in frequency domain provides the out-of-plane normal strain field component, simply by tracking any change in the stimulation condition for a thickness resonance. As such, the developed method yields an absolute, contactless and single-sided mapping of a local 3D strain field, in which both sample preparation and alignment procedure are ubiquitous. The ultrasonic strain gauge is applicable to any material, though under the restriction that a deterministic surface roughness is present. Results are presented for cold-rolled DC06 steel samples onto which skin passing of the work rolls is applied. The samples have been mechanically loaded, introducing plastic strain levels ranging from 2% to 35%. The ultrasonically measured strains have been validated with other strain measurement techniques, yielding good agreement. As the ultrasonic strain gauge provides all three strain field components, we extracted Lankford ratios for the DC06 steel sheet at different applied plastic strain levels revealing a strain dependent plastic anisotropy of the DC06 steel.
- Published
- 2014
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.