1. Evaluation of optical coherence tomography findings in patients with multiple sclerosis and glaucoma.
- Author
-
Uctepe F, Orenc P, Gungel H, and Emre Toprak U
- Subjects
- Humans, Female, Male, Prospective Studies, Middle Aged, Adult, Glaucoma, Open-Angle diagnosis, Visual Fields physiology, Optic Neuritis diagnosis, Tomography, Optical Coherence methods, Multiple Sclerosis diagnosis, Multiple Sclerosis complications, Retinal Ganglion Cells pathology, Nerve Fibers pathology, Optic Disk pathology, Optic Disk diagnostic imaging, Intraocular Pressure physiology
- Abstract
Purpose: Glaucoma and multiple sclerosis (MS) can cause optic disc pathology and, in this way, affect optical coherence tomography (OCT) data. In this context, the objective of this study is to investigate the changes in the mean, quadrant, and sector data measured by OCT in glaucoma and MS patients., Methods: The sample of this prospective cohort study consisted of 42 MS patients (84 eyes), 34 Primary open-angle glaucomas patients (67 eyes), and 24 healthy control subjects (48 eyes). The MS group was divided into two groups according to the presence of a history of optic neuritis. Accordingly, those with a history of optic neuritis were included in the MS ON group, and those without a history of optic neuritis were included in the MS NON group. The differences between these groups in the mean, quadrant, and sector data related to the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) were evaluated., Results: Superior nasal (SN), superior temporal (ST), inferior nasal (IN), and superior quadrant (SUP) values were significantly lower in the glaucoma group than in the MS group (p < 0.05). The mean superior GCC (GCC SUP) value was significantly lower in the MS ON group than in the glaucoma group (p < 0.05). On the other hand, SN, ST, inferior temporal (IT), IN, average RNFL (AVE RNFL), semi-average superior RNFL (SUP AVE RNFL), semi-average inferior RNFL (INF AVE RNFL), SUP, and inferior quadrant RNFL (INF) values were significantly lower in the glaucoma group than in the MS NON group (p < 0.05)., Conclusion: RNFL and GCC parameters get thinner in MS and glaucoma patients. While the inferior and superior RNFL quadrants are more frequently affected in glaucoma patients, the affected quadrants vary according to the presence of a history of optic neuritis in MS patients. It is noteworthy that the GCC superior quadrant was thin in MS ON patients. The findings of this study indicate that OCT data may be valuable in the differential diagnosis of glaucoma and MS., (© 2024. The Author(s), under exclusive licence to Springer Nature B.V.)
- Published
- 2024
- Full Text
- View/download PDF